Cisco Switching/Routing :: WS-C3560G-48TS-S / GB Port Shows (err-disabled)
Feb 28, 2013
I've got two two 3560s switchs, (WS-C3560G-48TS-S) that I'm trying to connect to each other using the GB ports over Fibre. We purchased the following GBICs, SFP 1000SX Transceiver and when we put them in the port it shows (err-disabled). Below is some information I pulled from one of the ports, but doesn't matter what port I use they all say the same thing.
ProdSwitchSW1#show run int g0/51
Building configuration...
Current configuration : 37 bytes
!
interface GigabitEthernet0/51
end
This switch randomly reboots throughout the day. I checked the stacks info and reported it was using crashinfo_12 (report below). I have access to the switch throughout the day if more config info needs to exported.
Cisco IOS Software, C3560 Software (C3560-IPBASEK9-M), Version 12.2(50)SE1, RELEASE SOFTWARE (fc2) Copyright (c) 1986-2009 by Cisco Systems, Inc.
I am having WS-C3560G-48TS switch with ios(c3560-ipbasek9-mz.122-58.E2.bin) and I am trying to use IPv6 feature in this switch model. More over I've upgraded this switch with many ios but none of them not supporting IPv6 feature. ios which supports IPv6 feature?
We are planning to run BGP on our pair of 3560G switch, I would like to know how many bgp routes it can support? it currently running on advance IP service.
My customer uses WS-C3560G-48TS-E switches in air traffic control systems. A requirement for one project is that the entire system be up and running in under five minutes. The WS-C3560G-48TS-E and its replacement - WS-C3560X-48T-E with C3KX-NM-1G - take about four minutes to start up. With other devices added in they exceed their required startup time.They also use WS-C3560V2-48TS-E switches which take about two minutes to start up but they want they GE.
1) Is there way to improve the start up time in the WS-C3560G-48TS-E and WS-C3560X-48T-E switches?
2) Is there another Catalyst switch with similar specifications to WS-C3560G-48TS-E and WS-C3560X-48T-E that has a quicker start up time.
I've got a pair of N7010's in a vPC domain with some FEX's attach running NX-OS 6.0.2. I am experiencing port failures on my N7K-M132XP-12L module the port got shut down due to internal errors with Error Disabled status and I am not able to bring the port back up. I am getting the following errors when I try to reset it. I am hoping is not hardware related as my vPC peer-link is on this module and I only have a single N7K-M1 32 XP-12L in each N7010. Replacing the module will be painful. [code]
I am configuring a Cat 2960 port for connecting a VOIP phone, authenticated by MAB. On connecting the phone, I get the port authenticated and assigned to the correct VLAN, with LLDP-MED advertising the correct voice vlan. However, I then see no traffic from the phone on the switch. I can see the MAC address of the phone is learned in the right VLANs, but the mac address is showing as "Drop", which normally means the address is statically configured to be blocked. There is no static mac address table blocking configured on the switch.
Switch Version Switch Ports Model SW Version SW Image ------ ----- ----- ---------- ---------- * 1 50 WS-C2960-48TC-L 15.0(1)SE3 C2960-LANBASEK9-M Port configuration interface FastEthernet0/1 description "Standard user port"
show cdp neighbors command shows two devices connected through the same local port?I have a Cisco 3560 that when I issue the "show cdp neighbors" command I get the following results: [code]
the question is why is this showing that Gig0/3 is being used twice to connect to two different devices. I have verified there is no hub connected to this port and in fact Switch3 is not connected to Switch1 at all yet it still shows up in the CDP table.
I have cleared the CDP table on every device at this location and still get the same results.
I would like to know if Catalyst WS-C3750G-48TS-E recognizes and understand Cisco VSS ( Virtual Switching System) . Is there a List available which tells us which Old Catalyst Switches or current switches understand Cisco VSS?
I recently removed a catalyst 2950 switch code version: c2950-i6q4l2-mz.121-13.EA1 ?I had an ASA 5505 connected as a switchport access to the 2950 on port 44. We will call the VLAN that the ASA sits on: VLAN 404. The 2950 had a trunk to our catalyst 6509 distribution switch carrying that VLAN 404. We also have a another VLAN for computers that sits on: VLAN 129, this is a standard DHCP vlan and it accounted for the rest of the switchports. The 2950 also has this trunked to our 6509 distribution switch.
Everything was working fine with that setup.After replacing the 2950 with a 3560 we started running into problems. The 3560 was configured the same exact way as the 2950. What was happening is that computers that sat on VLAN 129 started experiencing packet loss and were unable to work. It's as though the ASA was taking over the switch.
Is there a protocol that is enabled by defult on the 3560 that would do this?
My old switch software version is c3750-ipbase-mz.122-35.SE5 and model number is WS-C3750-48TS-S and my new switch Software version is c3750-ipservicesk9-mz.122-50.SE5.bin and model number is WS-C3750V2 . I want a compatible (prefer same) version of IOS which works on both the switches as both the switch will be in a stack..
When I view web page of 1410 radio is show ethernet enabled and up but radio as disabled and down. I have tried to enable but to no avail. Is this a sign my radio has gone bad?
Just spoke to the TAC and didn't get the information needed. When configuring ip dhcp snooping database I am adding this to my configuration:ip dhcp snooping database scp://dhcpsec@192.168.1.50/home/dhcpsec/switch1.dhcp.database.txt..I assumed that to do this I would either specify the password on the command line, similar to the way its done when using ftp/http, or that I would need to create a public/private key.I have enabled scp and can manually copy a file from the switch to the linux server. So I believe I have all the aaa commands correct. Cisco WS-C3560G-24PS System image file is "flash:/c3560-ipservicesk9-mz.122-55.SE.bin".
We are using WS-C3560G-48PS connected via UPS power supply. Whenever raw power supply gets fluctuates few of the IP phones (Alcatel) gets reset although switch is remain up and running. We checked the same by disconnecting the raw power supply but we didn't found any packet loss from the node which are connected through this switch. But few IP phone gets reset. What could be the reason
I have a WS-C3560G-24PS service as a distribution switch with six (6) WS-C2950T-24 connected to it. In looking at the utilization on the inter connect links no one is running close to a gig speed and this includes the link between this switch and the core. The CPU load (6%) and memory utilization (30%) on the switch do not seem bad so what else does one watch to see if it needs an upgrade?
We are starting tohave discussions about any needed upgrades on the network. I have an ocassional user that complaines about low performance but looking through the network I can find nothing glaring on a consistent basis that says an upgrade is warranted. I am however looking at things such as the above. Utilization on links, CPU, memory, etc.
We have 2 x C6506E and 2 x C3560-48's, they are all interconnected via port channels at 2Gb per channel. The 6506's are running CEF but the 3560's are not (The 3560's carry all our server traffic).When I do a show CEF on the 3560's it says %IPv4 CEF not running. There does not appear to be a global command to enable CEF on these switches.Is this an IOS version option or is not supported on the hardware platform?
I have two Switches which i need to put in a same stack - WS-C3750E-48TD and WS-C3750G-48TS . Possible to do so and also which IOS to put in both the switches as WS-C3750G-48TS is having lower RAM and flash.Whether can i put following IOS in these switches and connect them in a stack as i have read that IOS -- 15.0.1. SE are compatible with both the switches.
a . c3750e-ipbasek9-mz.150-1.SE.bin in switch - WS-C3750E-48TD
b. c3750-ipbasek9-mz.150-1.SE.bin in switch -- WS-C3750G-48TS
Situation: Currently WS-C3750G-48TS-(S or E) switches are on stack. Now these units will soon EOL on Jan. 30, 2013 and Cisco recommends that WS-C3750X-48T-S or WS-C3750X-48T-E will be used.
The question is: Will the new SKU works together in a stack with the old ones? Will there be no changes on the type of stacking cable to be used?
May I know why my 2960S-48TS-L takes 10 minutes to boot and start, some just take 1 minute, but one of them take up to 10 minutes, but after that it works fine, why?
We have a cisco stack with 5 ws-c3750-24p 12.2)55)SE3 c3750-ipbasek9-m switches. Can i add a switch to the stack that is the following model: ws-c3750g-48ts 12.2(25)see3 c3750-ipbase-m
I've been experimenting with the 'vlan dot1q tag native' command on a switch and it seems as though tagging the native vlan breaks vty access to my access point.With the 'vlan dot1q tag native' commnand applied, I lose management connectivity to the AP with 'no vlan dot1q tag native' applied, connectivity is restored. Why is this? Is it safe to say that one can access the AP via vty lines using ONLY untagged packets?
I have a brand new 2960S-48TS-L, plain vanilla with no extra module/boards etc. It boots up ok (the installed version is 12.2 (55) SE5) but then constantly cycles the following error, and doesn't accept any input whatsoever. After 5-10 minutes of cycling the error, the switch reloads and starts the process again.
PCIE0: link is NOT up. --------------CPU's PCIe SDR Registers-------------------- PE_DLPSET = 00401000 PE_UTLSET1 = 00000000
Our network administrator restricts all our new 1Gb switches to only 100Mb, to which he claims it will increase overall performance. Preventing devices from bottlenecking the network. (that is, only restricting the main switch ports, not the uplinks)For example we have a new building with 2x WS-C2960S-48TS-L connected together with FlexJack and then a 1Gb Fiber connection back to our core switch.
This building is on it's own subnet and there is little broadcast traffic. I don't see the point other than it hinders the potential speed we could use. Labs are set up in this building and 1Gb is MUCH faster when it comes to imaging and software deployment.
why my SSID still displays even though I have the SSID Broadcast "Disabled" for 5 GHz and 2.4Ghz configurations. The name of my network shows full signal strength and a lock next to the name but I was under the impression if I have disabled the SSID broadcast it shouldn't show up at all and would force a user to manually input the network name when trying to connect to it. I have the router configured to only allow certain MAC addresses wireless access as well. Router is running Firmware Version: 1.0.03.Also, my primary computer my iMac running 10.7.2 boots up or is brought out of sleep mode I constantly need to go up to the top of my screen and re-select my network.
I have a 3560 connected to an edge device and I keep etting this error. I have turned off proxy arp and turned off ip cef under the interface, however I lot connectivity to the internet when I did that. I can't seem to find any documentation on this error. I understand what it means, I just don't know how to resolve the problem.
I have a 3560 connected to an edge device and I keep etting this error. I have turned off proxy arp and turned off ip cef under the interface, however I lot connectivity to the internet when I did that. I can't seem to find any documentation on this error. [code]
We have a pair of 6513s and upgraded the IOS version to 12.2(33)SXI4a. After the upgrade we noticed VTP Pruning was disabled: [code] Is there any effect to production we need to to consider when re-enabling? (In other words, do we need to wait until a maintenance window to enable?)Also, we are using VTP v2 (and v1...) on our VTP Client 3560 access switches.