Cisco Switching/Routing ::WS-C3560G-48PS - IP Phone Gets Restart While Power Fluctuate

Jun 21, 2011

We are using WS-C3560G-48PS connected via UPS power supply. Whenever raw power supply gets fluctuates few of the IP phones (Alcatel) gets reset although switch is remain up and running. We checked the same by disconnecting the raw power supply but we didn't found any packet loss from the node which are connected through this switch. But few IP phone gets reset. What could be the reason

View 2 Replies


ADVERTISEMENT

Cisco Switching/Routing :: WS-C3560G-48PS-S Power Cord

Nov 23, 2011

I need to prepare a Bill of Material for WS-C3560G-48PS-S switch.
 
Whether we should go for CAB-AC-JPN -  AC power cord for Japan  OR CAB-AC-ACE   AC power cord for Europ

View 2 Replies View Related

Cisco Switching/Routing :: ASA 5505 Connected To WS-C3560G-48PS

Nov 2, 2011

I recently removed a catalyst 2950 switch code version: c2950-i6q4l2-mz.121-13.EA1 ?I had an ASA 5505 connected as a switchport access to the 2950 on port 44.  We will call the VLAN that the ASA sits on: VLAN 404.  The 2950 had a trunk to our catalyst 6509 distribution switch carrying that VLAN 404.  We also have a another VLAN for computers that sits on: VLAN 129, this is a standard DHCP vlan and it accounted for the rest of the switchports.  The 2950 also has this trunked to our 6509 distribution switch.
 
Everything was working fine with that setup.After replacing the 2950 with a 3560 we started running into problems.  The 3560 was configured the same exact way as the 2950.  What was happening is that computers that sat on VLAN 129 started experiencing packet loss and were unable to work.  It's as though the ASA was taking over the switch. 
 
Is there a protocol that is enabled by defult on the 3560 that would do this?

View 4 Replies View Related

Cisco Switching/Routing :: WS-C3560-48PS-S Show Power Inline But No Power Available

Apr 14, 2013

We have two switches of the same model (WS-C3560-48PS-S) that are not providing PoE. I'm trying to remotely determine what the cause of the issue is.
 
Here is some output.
 
Hostname#show power inlineAvailable:0.0(w)  Used:0.0(w)  Remaining:0.0(w)
Interface Admin  Oper       Power   Device              Class Max                            (Watts)--------- ------ ---------- ------- ------------------- ----- ----Fa0/1     auto   off        0.0     n/a                 n/a   15.4Fa0/2     auto   off        0.0     n/a                 n/a   15.4Fa0/3     auto   off        0.0     n/a                 n/a   15.4Fa0/4     auto   off        0.0     n/a                 n/a   15.4Fa0/5     auto   off        0.0     n/a                 n/a   15.4Fa0/6     auto   off        0.0     n/a                 n/a   15.4Fa0/7     auto   off        0.0     n/a                 n/a   15.4Fa0/8     auto   off        0.0     n/a                 n/a   15.4Fa0/9     auto   off        0.0     n/a                 n/a   15.4Fa0/10    auto   off        0.0     n/a                 n/a   15.4(code)

View 1 Replies View Related

Cisco Switching/Routing :: 3560G-48PS-S - PoE Lockout After Power Outage

Oct 27, 2011

We had some problems with 3560G-48PS-S switches and PoE for our phones. IOS is 12.2(50)SE3. There were some problems after power outage. The switches didn't reboot because we have two eletric circuits. But after the problems we had no PoE on all ports.
 
The switches logged to following syslog message:
 
%ILPOWER-3-CONTROLLER_PORT_ERR: Controller port error, Interface Gi0/17: Power Controller reports power supply VDD under voltage
 
I can't find any informations in the error message decoder for that. But there was another thread here with quiet the same message, but another problem regarding RPS2300.
 
After reloading the device all works fine again. The workaround with the commands "power inline never" and "power inline auto" I didn't know till today.
   
Some information about that syslog message?
 
My guess is that there was a voltage swing and the switch powered down its supply? Is that possible?

View 5 Replies View Related

Cisco Switching/Routing :: 3750X - 48PS Switches Power Stacking

Mar 28, 2012

In my office we bought 7 cisco 3750X - 48PS switches. We configured Data Stacking between those switches. We also want to configure Power Stacking between those 7 devices.
 
I found in the Data Sheet that we can only configure 4 devices in power stacking at a time. If it is like that how to configure the rest of 3 devices. Need configuring power stacking between those devices in a better way..

power stack cable part no we have is
CAB-SPWR-30CM

View 2 Replies View Related

Cisco Switching/Routing :: 3560v2 / Ws-c3560v2-48ps-s (inline Power Failure)

Jul 22, 2012

I have a switch 3560v2 with an IOS 12.2(50) SE1.All the lights ON and console error message below:POST: inline power post failed for port 0 up to port 15.Then, the system hanged and all lights (indicator) ON.

View 5 Replies View Related

Cisco Switching/Routing :: Stacking WS-C3750-48PS-S With WS-C3750G-48PS?

Apr 17, 2013

I have production stack in the following config:
 
Switch   Ports  Model              SW Version              SW Image
------   -----  -----              ----------              ----------
*    1   52     WS-C3750-48P       12.2(25)SEE4            C3750-IPSERVICESK9-M
     2   52     WS-C3750-48P       12.2(25)SEE4            C3750-IPSERVICESK9-M
 
I want to add 3-rd switch to it:
 
Switch: WS-C3750G-48PS   12.2(25)SEE3           C3750-IPSERVICESK9-M
 
Will this configuration work? My main concern is IOS difference?

View 3 Replies View Related

Cisco Switching/Routing :: Stacking WS-C3750-48PS-S And WS-C3750G-48PS?

Mar 3, 2013

I have 3750-48PS-S in production and would like to stack it with C3750G-48PS. Both switches are running code:

c3750-ipservicesk9-mz.122-50.SE3.bin

View 3 Replies View Related

Cisco Infrastructure :: Converting WS-C3560G Switch To DC Power?

Apr 15, 2013

What needs to be done to convert a WS-C3560G-24TS-E to DC power? 

View 2 Replies View Related

Cisco Switching/Routing :: Random Reboots On WS-C3560G-48TS

Mar 7, 2012

This switch randomly reboots throughout the day. I checked the stacks info and reported it was using crashinfo_12 (report below). I have access to the switch throughout the day if more config info needs to exported.
  
Cisco IOS Software, C3560 Software (C3560-IPBASEK9-M), Version 12.2(50)SE1, RELEASE SOFTWARE (fc2)
Copyright (c) 1986-2009 by Cisco Systems, Inc.

[Code].....

View 1 Replies View Related

Cisco Switching/Routing :: How To Reset Password On WS-C3560G-24TS

May 1, 2012

how to reset password on WS-C3560G-24TS?

View 1 Replies View Related

Cisco Switching/Routing :: WS-C3560G-48TS-S / GB Port Shows (err-disabled)

Feb 28, 2013

I've got two two 3560s switchs, (WS-C3560G-48TS-S) that I'm trying to connect to each other using the GB ports over Fibre.  We purchased the following GBICs, SFP 1000SX Transceiver and when we put them in the port it shows (err-disabled).  Below is some information I pulled from one of the ports, but doesn't matter what port I use they all say the same thing. 

ProdSwitchSW1#show run int g0/51
Building configuration...
 Current configuration : 37 bytes
!
interface GigabitEthernet0/51
end

[code]....
 
Configuration register is 0xF

View 3 Replies View Related

Cisco Switching/Routing :: WS-C3750G-48PS IOS Upgrade

Sep 11, 2012

I am in the process of upgrading our stack of 4 switches consist of WS-C3750G-48PS. Upon reading release notes found that there are two versions of release notes 1 day apart, the one 02 Sep 2012 saying that WS-C3750-48PS is not supported in this version. Then in release next day 03 Sep 2012 that note has been removed. Which one is correct. Is it supported with my model of switch or not. Also unable to update boot path in the stack switches, "switch all" is not supported in the current IOS. Any other way to update it. Master switch has new boot path but unable to change in slaves.

View 2 Replies View Related

Cisco Switching/Routing :: Could Not See RPS Status On WS C3750G 48PS

Dec 7, 2011

We recently connected a RPS 2300 to our switch WS-C3750G-48PS-E with IOS c3750-ipservicesk9-mz.122-53.SE2.bin.However i do not see any RPS details in the"show env" output.I believe i should get the RPS Name and its Serial and the port number in the output, but i am not finding it in the output. I did reload the switch but still couldnot get this udpated.

View 3 Replies View Related

Cisco Switching/Routing :: WS-C3560G-24PS Configuring Ip Dhcp Snooping Database With Scp

Feb 10, 2011

Just spoke to the TAC and didn't get the information needed.  When configuring ip dhcp snooping database I am adding this to my configuration:ip dhcp snooping database scp://dhcpsec@192.168.1.50/home/dhcpsec/switch1.dhcp.database.txt..I assumed that to do this I would either specify the password on the command line, similar to the way its done when using ftp/http, or that I would need to create a public/private key.I have enabled scp and can manually copy a file from the switch to the linux server. So I believe I have all the aaa commands correct. Cisco WS-C3560G-24PS System image file is "flash:/c3560-ipservicesk9-mz.122-55.SE.bin".

View 3 Replies View Related

Cisco Switching/Routing :: Which Ios Will Support IPv6 Feature In WS-C3560G-48TS Switch

Feb 18, 2013

I am having WS-C3560G-48TS switch with ios(c3560-ipbasek9-mz.122-58.E2.bin) and I am trying to use IPv6 feature in this switch model. More over I've upgraded this switch with many ios but none of them not supporting IPv6 feature. ios which supports IPv6 feature?

View 3 Replies View Related

Cisco Switching/Routing :: WS-C3560G-24PS - Checking Utilization And / Or Performance On Switch

Apr 23, 2012

I have a WS-C3560G-24PS service as a distribution switch with six (6) WS-C2950T-24 connected to it. In looking at the utilization on the inter connect links no one is running close to a gig speed and this includes the link between this switch and the core. The CPU load (6%) and memory utilization (30%) on the switch  do not seem bad so what else does one watch to see if it needs an upgrade? 
 
We are starting tohave discussions about any needed upgrades on the network. I have an ocassional user that complaines about low performance but looking through the network I can find nothing glaring on a consistent basis that says an upgrade is warranted. I am however looking at things such as the above. Utilization on links, CPU, memory, etc.

View 2 Replies View Related

Cisco Switching/Routing :: C3560G-48 - IOS Version Option Or Not Supported On Hardware Platform

Feb 6, 2012

We have 2 x C6506E and 2 x C3560-48's, they are all interconnected via port channels at 2Gb per channel. The 6506's are running CEF but the 3560's are not (The 3560's carry all our server traffic).When I do a show CEF on the 3560's it says %IPv4 CEF not running. There does not appear to be a global command to enable CEF on these switches.Is this an IOS version option or is not supported on the hardware platform?

View 3 Replies View Related

Cisco Switching/Routing :: Does 3750-48ps Have IPv6 Feature Set

Dec 13, 2011

I've a 3750-48ps-s running ios version: c3750-advipservicesk9-mz.122-46.SE.bin
 
I've tried to configure ipv6 on an interface but it does not give me the option.
 
How do I know if my ios is IPv6 capable?

View 1 Replies View Related

Cisco Switching/Routing :: 3750 48PS Stack IOS Upgrade

Jul 9, 2012

I want to upgrade the IOS version of 3750 48PS switches. these stacks are located on different building some of the them having 2 members and some have 3 members in a stack.step by step to upgrade the IOS of these switches.

View 1 Replies View Related

Cisco Switching/Routing :: WS-C3560G-24PS / Native Vlan Tagging And Vty Access To Autonomous APs?

Jan 14, 2013

I've been experimenting with the 'vlan dot1q tag native' command on a switch and it seems as though tagging the native vlan breaks vty access to my access point.With the 'vlan dot1q tag native' commnand applied, I lose management connectivity to the AP with 'no vlan dot1q tag native' applied, connectivity is restored. Why is this? Is it safe to say that one can access the AP via vty lines using ONLY untagged packets? 
 
SWITCH
Model: WS-C3560G-24PS
Code: c3560-advipservicesk9-mz.122-46.SE
--Abbreviated CONF
 vlan dot1q tag native

[code]....

View 14 Replies View Related

Cisco Switching/Routing :: 3750-48PS-S No Lights On Chassis But Fans Work

Apr 5, 2012

I  have a 3750-48P when plugged in has fans that spin up, but no lights on the front of the chassis.  Does this mean the power supply is bad?  If its bad, why do the fans power up? Also, i am not receiving any data through the console.

View 6 Replies View Related

Cisco Switching/Routing :: WS-C3560-48PS SFPs Compatible With 2960-S Switches

Jan 3, 2013

I need to replace an older 3560 with a new 2960-S and am wondering if the SX SFPs I already have will be compatible with the 2960-S. [code] I cannot find any way to get the part numbers of the SFPs.

View 7 Replies View Related

Cisco Switching/Routing :: WS 3560G 48PS Invalid Dhcp Options And Unable To Parse

Jan 13, 2013

I have configured DHCP snooping on a WS-3560G-48PS running IOS 12.2(58)SE2 ipservicesk9 variant.When I enable DHCP snooping clients don't get IP addresses, when DHCP snooping is disabled, everything works fine.I have set up a SPAN port and run a capture (attached) on the traffic. Wireshark notes the Seconds elapsed field appeared to be encoded in little-endian but only on some packets. Apart from that, I can see nothing wrong with the DHCP Offer responses from my DHCP server.Attachment config.txt contains the interesting parts of the  configuration. Please note g0/32 has been set to ARP inspection trust as  without working DHCP snooping it would require a static bind.Is there any way of figuring out which option can't be parsed? Is there a way to force forwarding of unparsable DHCP packets while still running DHCP snooping?

View 3 Replies View Related

Cisco Switching/Routing :: Inter Access Switch Fiber Connectivity 2960-48PS

Jan 16, 2012

I had a strange issue yesterday when onsite installing a new access switch.Port capacity full on a two switch stack of 3750 x48 PS switches (WS-C3750- 48PS-E)- New 2960 x48 PS - WS-C2960S-48FPS-L racked, with the plan of using it just as an edge switch via SFP Stacking cable.Setup the two connecting ports with simple initial config: - switchport mode trunk- no encapsulation option on the 2960, default dot1q- dot1q set on 3750 port- no shut on both sides.Connected the SFP Stacking cable but it didnt work:- %PHY-4-SFP_NOT_SUPPORTED: The SFP in Gi1/0/1 is not supported
 
This is ok as I had a backup:- Next step tried using 2 x Short Haul SFP SX GBIC's with LC - LC OFNP 50/125 fibre patch lead  - no joy- Extra backup of 2 x Long Haul SFP LX GBIC's with the same fibre patch - no joy- Checked the fibre and it was not a cross over so transmit and receive going down the same side, switchedand still would not come up.- Used Fibre as a straight through and still the same.In all cases there was no indication of any life in the connection.It is pointing to a faulty fibre patch lead but I know it has worked in the past. Could it be something to do with the config or device incompatibility? Or any setting I need to activate?

View 1 Replies View Related

Cisco Switching / Routing :: C3560 - 48PS Port / Get Any Device To Talk To DHCP Server?

Sep 11, 2011

I have a c3560 that on Port 1 I can not get any device to talk to the DHCP server.Previously there was a client connected to this port however over the weekend he stated he lost connectivity.

In my troubleshooting I have connected that client to another port and now he is good to go...I connected my laptop and tried to connect to the network however I could not.I checked the logs and did not see anything that lead me to think it was having problems.

Is there another way to shut this down and hopefully start it back up without having to restart the entire switch?

View 4 Replies View Related

Cisco Routers :: RV180W Power Outage - No Automatic Restart?

Dec 16, 2012

I have two RV180W's which are excellent units in almost all respects.  The one really noticeable problem is that when I have a power outage (which I have quite a lot in rural France) my RV180W does not automatically restart when the power is restored.  Is it not possible to fix this in the next firmware upgrade, or have I missed something in the router menu/setup which I should have set.....?

View 1 Replies View Related

Cisco Switching/Routing :: C3750-48PS Switch Is Stuck In SYST Mode On Front Panel

Dec 13, 2012

After powering up a WS-C3750-48PS switch, Normal POST LED flashing of lights does not happen, instead the switch is stuck in SYST Mode on the front panel. My attempt to hold down the mode button upon powering up for 15 sec fails to reboot the switch. I cannot console to the switch. Is this switch unrecoverable? Should I RMA with TAC?

View 5 Replies View Related

Cisco Switching/Routing :: WS-C3750G-48PS / Unable To Update Boot Path In Stack Switches

Sep 11, 2012

I am in the process of upgrading our stack of 4 switches consist of WS-C3750G-48PS. Upon reading release notes found that there are two versions of release notes 1 day apart, the one 02 Sep 2012 saying that WS-C3750-48PS is not supported in this version. Then in release next day 03 Sep 2012 that note has been removed. Which one is correct. Is it supported with my model of switch or not.also unable to update boot path in the stack switches, "switch all" is not supported in the current IOS. Master switch has new boot path but unable to change in slaves.

View 1 Replies View Related

Cisco Switching/Routing :: 3750 - Power Stack Has Unbalanced Power Supplies

Jun 9, 2013

I am receiving the following error on 3750 stack switches. have already verified the power status and found ok.
 
IOS used: Cisco IOS Software, C3750E Software (C3750E-UNIVERSALK9-M), Version 12.2(55)SE3, RELEASE SOFTWARE (fc1)

211540: Jun 10 10:45:17.935 UTC: %PLATFORM_STACKPOWER-4-UNBALANCED_PS: Switch 4's power stack has unbalanced power supplies
211541: Jun 10 10:46:18.045 UTC: %PLATFORM_STACKPOWER-4-UNBALANCED_PS:

[Code]....

View 1 Replies View Related

Cisco Switching/Routing :: Stack-power 3750x / FRU Power Supply Is Not Responding

Sep 4, 2012

After stacking two 3750X switches, with four equal power-supply's, with StackWise and PowerStack , still got the next message every few hours %PLATFORM_ENV-1-FRU_PS_ACCESS: FRU Power Supply is not responding (gn4m-rt1p08-04-2)( note that the message revers to the second switch in the stack ) although the stackwise and powerstack on the switches is oke and are working correctly. !
 
Config  : Stack-power in power-sharing mode/strict With CLI on the switch : All the power supply's and stack-power details, prio look OK.
 
Only: LMS prime /inventory/cisco-view/configure/power supply status  result :  some power supply's are marked as disabled.with the command  > power supply 2 slot a off/on I manage to get the status back to "normal", but after a few hours some power supply's are again marked as "disabled".
 
Looks like SNMP en IOS difference from opinion.
 
Hardware
WS-C3750X-24S-S
C3KX-PWR-350WAC
 
Software
15.0(2)SE
C3750E-UNIVERSALK9-M

View 5 Replies View Related

Cisco Switching/Routing :: 6500 - Power-Redundancy Mode Combined And Power Fail

Feb 28, 2011

I have a 6500 chassis with 2 power supplies. At the moment  I am using the default configuration:
 
power-redudancy mode redundant
 
The problem is that an inserted module is in "power deny" state due too insufficient power.
 
I know, that It's not a good idea to change into combined mode (loss of redundancy), but my customers requested this anyway.
 
So I will change to combined mode. So here's the 1 million dollar question: "Which modules will go into power deny, if one of my power supplies fails?"
 
The 6500 config guide states:
 
"Power supply is removed withredundancy disabled
• System log and syslog messages are generated.
• System power is decreased to the power capability of one supply.
• If there is not enough power for all previously powered-up modules, some modulesare powered down and marked as power-deny in the show power oper state field."
 
Well, do you know if there's any way to configure some kind of priority? E.g. I definetly don't want by 10Gig Module or WiSM module to be in power deny. Can i statically make sure, those module will be powered on for sure? Like: "power enable module slot_number" How is this calculated? Or is random?

View 3 Replies View Related







Copyrights 2005-15 www.BigResource.com, All rights reserved