Cisco Switching/Routing :: Catalyst WS-C3750-48P And WS-C3750G-16TD Stack?
Jan 1, 2012
I have 8 switch stack consisting of six WS-C3550-48P and two WS-C3750G-16TD running software vesrion 12.2(25) SEB1. When I added new C3750v2-24PS (running image 12.2(50) SE5) in stack so I up-graded the image of existing 8 switches with latest veriosn 12.2(50) SE5. Once I have done with the upgrade then all ports of my stack switches went down after around five minuts. Is it image compatibility issue with existing switches or something else?
can i stack cisco (ws-c3750G-12s) with (ws-c3750X-24p-poe-s) with (ws-c3750-48p-10/100 poe) i mean even a switch is 10/100 and the other switch is 10/100/1000?
Currently there are three stacked WS-C3750G-24TS-1U on data centre. I am going to buy a WS-C3560X-48T-L to use 10GbE module. Is it possible stack this switch "WS-C3560X-48T-L" to current switches "WS-C3750G-24TS-1U" ?
I have two Switches which i need to put in a same stack - WS-C3750E-48TD and WS-C3750G-48TS . Possible to do so and also which IOS to put in both the switches as WS-C3750G-48TS is having lower RAM and flash.Whether can i put following IOS in these switches and connect them in a stack as i have read that IOS -- 15.0.1. SE are compatible with both the switches.
a . c3750e-ipbasek9-mz.150-1.SE.bin in switch - WS-C3750E-48TD
b. c3750-ipbasek9-mz.150-1.SE.bin in switch -- WS-C3750G-48TS
I do have C3750G-12s switch which is not able to boot as of the expected. Every time when I break the stack and try to use console i got a weird output from my console output. we need the stack to be break and use those switch separtally .
I have a situation. I am running two-switch 3750-stack and it crashed this morning. IOS version the switches is: "flash:c3750-ipservicesk9-mz.150-1.SE.bin"
SRPRSRGBYA#
Log Buffer (10000 bytes): 3:40.840: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan104, changed state to up Nov 3 13:13:40.840: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan201, changed state to up Nov 3 13:13:40.840: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan202, changed state to up M-1-CRASHED: (SRPRSRGBYA-1) Nov 3 13:18:13.336: %PLATFORM-1-CRASH(code)
We have a cisco stack with 5 ws-c3750-24p 12.2)55)SE3 c3750-ipbasek9-m switches. Can i add a switch to the stack that is the following model: ws-c3750g-48ts 12.2(25)see3 c3750-ipbase-m
We have existing stack of 3 units of WS-C3750-48TS-S ( 100 mbps ports with Gigabot uplinks). with IOS as follows, Can we add WS-C3750G-48PS-S in this same stack (this is 48 Gigabit ports)?
According to cisco manual in order to change SDM template i need to reboot switch, but when i have C3750-X stack do i need to reboot stack or maybe will be enough reboot in sequence the stack members?
Is it possible to upgrade a c3750-stack one member at a time to avoid downtime? I need to keep L3-functionality up.
If I have one etherchannel from access-switch (2 channel-ports in 3750, in different stack-members), my 3750-stack as a distribution layer switch, and another etherchannel (also spread over multiple stack members) to core, can I upgrade the entire stack without traffic interruption?
a) I have three C3750-X switch stack together as my SAN switch and running on the new 15.0 release which is 15.0(1) SE.
b) Recently the master switch rebooted without any explanation. Create ticket with TAC and got an answer that it is due to a bug with ID: CSCtr31957.
My question is, which release that should i choose either the 15.0(1) SE3 or the latest 15.0(2)? Will it affect any of my configuration if i change to 15.0(2)?
Finally, what is the best practice to upgrade IOS in a stack whether to upgrade it 1 switch at a time or do it to all at once?
I have changed the universal IOS on the 3750X to IP base..but they still wont come up as a stack. On the 3750X I don't see any log entry, on 3750G (major version mismatch).
We have WS-C3750-24FS switches stacked supporting users on our LAN. I want take advantage of the netflow capabilities of the WS-C3750X using the C3KX-SM-10G card.
Would I be to see netflow data coming from the WS-C3750's if I stacked it with the WS-C3750X?
Also I read that the C3KX-SM-10G card would support a 1G SFP is that correct?
WS-C3750G-24TS-S1U switch stack with high CPU utilization. 3 switches are stacked and using PBR on that. I am attaching the show cpu process as an attachment.The current template is "desktop routing" template.The selected template optimizes the resources in the switch to support this level of features for 8 routed interfaces and 1024 VLANs. [code]
I would like to know if Catalyst WS-C3750G-48TS-E recognizes and understand Cisco VSS ( Virtual Switching System) . Is there a List available which tells us which Old Catalyst Switches or current switches understand Cisco VSS?
I am in the process of upgrading our stack of 4 switches consist of WS-C3750G-48PS. Upon reading release notes found that there are two versions of release notes 1 day apart, the one 02 Sep 2012 saying that WS-C3750-48PS is not supported in this version. Then in release next day 03 Sep 2012 that note has been removed. Which one is correct. Is it supported with my model of switch or not.also unable to update boot path in the stack switches, "switch all" is not supported in the current IOS. Master switch has new boot path but unable to change in slaves.
I am having an issue on a Cisco 3750 stack where when the stack master is rebooted, all my lacp port-channels drop and then come back up again. After doing some investigation It seems that it is happening because of lacp using the stack master mac-address as part of the system-id, so when the stack master reboots, the stack mac changes. I see that there is the command: stack-mac persistent timer 0
There is this warning about using this command:
When you configure this feature, a warning message displays the consequences of your configuration. You should use this feature cautiously. Using the old master MAC address elsewhere in the domain could result in lost traffic.
My question are:
Are there any other consequences to using this command (apart from moving the switch/mac to another location in the network)It mentions 'If the entire switch stack reloads, it acquires the MAC address of the master as the stack MAC address' Is this still the case if you have the stack-mac persistent timer to 0? Does using channel-group mode on for the port-channels still use the same mechanism of having a system-id? (Will the channels flap using 'mode on' when rebooting the stack master.
I am not on site and I have not seen a WS-C3750V2-24PS-S. Customer has a stack of 6 x WS-C3750V2-24PS-S and one unit has failed. We do not have a WS-C3750V2-24PS-S spare. Can we replace it with a standard WS-C3750-24PS-S (not V2) switch and be part ofthe stack.
1. Are there any traps gotchas? 2. What about IOS versions - aren't they different for V2 switches 3. Are the stack ports and stack cables same for both WS-C3750V2-24PS-S and WS-C3750-24PS-S 4. What is the main reason for bringing out the V2 switches. What features do they have extra?
How would I go about stacking 4 Cisco Catalyst 2960-48PST-L switches? The one switch needs to accept a fiber connection from a distribution switch. Do I have to buy flexstack module and cables? If so where does the module go on the switch? If this switch cannot do this set up, any other switch I should look at.
Any experience with bundling a 10GB interface on a 3750G-16TD-S with a WS-C3750X-48T-S with a 10GB interface. I have worked with 5 different TAC engineers and so far I have not gotten an answer on why the switch will not let me bundle the 10GB with another 10GB interface.
Same switch Stack – not a cross stack.
Tried every configuration possible with no luck. I originally thought it might be the stack-ring speed – I corrected that today and it is running at 32GB –
The only thing I can think of now is it might be a hardware limitation on the 3750G-16TD-S ?
Q. What performance of the 10 Gigabit Ethernet port on the Cisco Catalyst WS-C3750G-16TD switches?
A. The Ten Gigabit Ethernet uplink on the Cisco Catalyst WS-C3750G-16TD switches is 1.25:1 oversubscribed and provides maximum throughput of 8Gb/s. –
if I read the Datasheet of Catalyst 3750X-Series-Switches it is possible to connect a new X-Switch to an existing and old Catalyst 3750-Series Stack.What kind of requirements are needed? Only same IOS-Version in the hole Stack and if possible same Feature-Set? .... like in a normal NOT mixed Stack?
I want to run rolling-stack upgrades on several stacks containing Catalyst 3750X-switches. I have done as follows: Configured the redundant uplinks as active and stand-by.Started to upgrade by using archive download-sw /rolling-stack-upgrade /overwrite /reload The upgrade starts as expected BUT switch number 2 in the stack is reloaded BEFORE switch 1 is finnished, the result is of course downtime for the stack. The documentation says something about the command "boot time", but what is this command doing? The default seems to be 7 minutes, it this parameter the time the upgrade-process waits before booting the next switch in the stack? I would expect that switch number 2 is reloaded when switch 1 is up again after reload, and not after an absolute number of minutes, is the rolling-stack-upgrade not working this way ?
On first floor, I have two stack switches and each stack has got 4 switches. they all are working fine.Now the client would like to add one more stack on the 2nd floor. But the second floor switches are different when compared to the 1st floor switches.
can you have differnt IOS among different stacks. I knew in a stack we need all the switches should have same IOS version. But in between two stacks to communicate do we need same IOS or they can be on differnet IOS?
1st floor switches have 15.0 version and 2nd floor new switches has 12.2.58. Is this ok ?
1st floor switches are 3500 series ( Note: only one one Vlan 20 we are using on the both stack switches and we would like add same Vlan 20 on to the new stack)
2nd floor switches aew 2 catalyst 2960 switches.
Note: on the second floor switches one is 24 port switch and the other one is 48 port switch. so can i make them as a stack?
We have already done cabling from 1st floor to second floor. So no problem with that at all.
I have two Cisco 48 port Catalyst 2960-S series SI. Instead of buying the pricy stack modules can I only use the SFP+cable to connect them as stack? which type of SFP+cable should I buy? do I need any license to use those SFP ports?
The Catalyst 3750 switch reboots, and the " Reloading because of stack merge or communication failure" error message appears.
I saw this issue at "Cisco wiki" but the resolution in that page is just "Open a case with TAC". Because of the reasion is H/W Problem.
Is The resolution only one ? anything else? The 3750 does not use Stack.It is just stand alone. So i think it has other resolution as "disabling Stack" or another one. How about my opinion ? Is the Resolution only "Open a Case with TAC"