Cisco Switching/Routing :: Option For WS-C3560X-48T-S
Jul 16, 2012Im trying to find an affordable Cisco switch with similar capabilities and features as the WS-C3560X-48T-S (L2/L3 routing as in IP Base, dual power supply, etc.).
View 2 RepliesIm trying to find an affordable Cisco switch with similar capabilities and features as the WS-C3560X-48T-S (L2/L3 routing as in IP Base, dual power supply, etc.).
View 2 RepliesI got a pair of new C3560X-24T-S switches with C3KX-NM-10G modules, and am trying to get a long distance 10G link up using 3rd party SFP-10G-ER SFPs (XGIGA with Cisco coded IDPROMs)I've enabled use of unsupported transcievers with the following commands:service unsupported-transceiver no errdisable detect cause gbic-invalidAfter that the switches accepts the SFPs but I get no light (sh int trans shows Tx -40), but if I insert a supported SFP first and then switches to my ER SFPs I get them to start transmitting, however I still don't LINK on the interface.I've tried with both 12.2(55)SE3 (that the switches came with) and 15.0(1)SE3 with same results.I know SFP-10G-ER SFPs are not supported on these switches, but are scheduled for the 15.0(2) release, but I was under the impression that they should already work using the above commands to enable the use of unsupported SFPs.So my question is basically: Is the new code in 15.0(2) really needed to make ER SFPs work, so I should just wait for that release, or are my 3rd party SFP simply broken/un-compatible with these switches?Also, could reprogramming them to look like SFP-10G-LR SFPs, which are supported, make any difference, or should it already have worked now with service unsupported-transceiver enabled if they were compatible?
View 5 Replies View RelatedCurrently there are three stacked WS-C3750G-24TS-1U on data centre. I am going to buy a WS-C3560X-48T-L to use 10GbE module. Is it possible stack this switch "WS-C3560X-48T-L" to current switches "WS-C3750G-24TS-1U" ?
View 1 Replies View RelatedLet me start with some infrastructure details ...
Cisco C2901 as our Main Router
Cisco UC520 as Communication Platform
Cisco C3560x as Core-Switch
VLAN 10 : Data
VLAN 100 : VOICE
Everything is working but i m not sure if the switchport config is right in that way.
As an example :
interface GigabitEthernet 0/6
switchport access vlan 10
switchport mode access
switchport voice vlan 100
spanning-tree portfast
When we connect an Cisco 7971g and an pc everything is working fine. But when i start wireshark on the pc behind the phone you see a lot of UDP Traffic source UC520 destination 239.10.16.8 or 239.10.16.16. At this point i m getting confused. So i start looking for the cisco phone config, VLAN ID on the phone is 100 (i think that is ok) but the PC-VLAN part is empty?
The main thing is, how can i stop this cisco-sccp traffic on the pc port (prtg shows me a average of 200 kbit/s) i think it is an config fault.
I have a Switch model WS-C3560X-24P with SW Version 12.2. (55) SE5 and SW Image C3560E-UNIVERSALK9-M. Now I get messages from 3 ports that:% ILPOWER-5-IEEE_DISCONNECT: Interface Gi0/12: PD removed. The strange thing is that there is nothing connected to these ports and they are like "notconnect»
An excerpt of the log looks like this:
1469058: Feb 18 09:08:33.945 CET: %ILPOWER-5-IEEE_DISCONNECT: Interface Gi0/12: PD removed 1469060: Feb 18 09:08:49.279 CET: %ILPOWER-5-POWER_GRANTED: Interface Gi0/12: Power granted 1469061: Feb 18 09:08:50.310 CET: %ILPOWER-5-IEEE_DISCONNECT: Interface Gi0/12: PD removed 1469063: Feb 18 09:09:02.280 CET: %ILPOWER-5-POWER_GRANTED: Interface Gi0/12: Power granted 1469064: Feb 18 09:09:03.413 CET: %ILPOWER-5-[Code]....
I have recently installed 4 3560 (WS-C3560X-48T-S) Switches. At first the switch comes up, indicating all connected ports with a green LED. Whenever i unplug a cable and plug it back in, the status LED will stay off. The same thing happens when I push the mode button and cycle throgh the different modes, i lose certain LEDs.
I'm using 12.2(53)SE2, another user reported the same issues under 12.2(55)SE1 .
I would I upgrade this from a LAN base to ip services?
View 2 Replies View RelatedDoes the Cisco WS-C3560X-24P-S switch supports ip flow export?
View 1 Replies View RelatedI have a WS-C3560X-24 and attached to that are some 9 acces switches, for some weeks now my 3560 reboots some time what couse that the other 9 switches are down for some minuts as well and i dont want this of course. the reboot happens at random times and some times one week not and then like yesterday afternoon it rebooted again.
when i check the Flash directory there is no crash file and when i look at the logging its clean and just shows the startup. it's not the powersuply it's redundend and more L3 switches are attached to this power source and they dont reboot.
L3_AIM#sh versionCisco IOS Software, C3560E Software (C3560E-UNIVERSALK9-M), Version 12.2(55)SE3, RELEASE SOFTWARE (fc1)Technical Support: [URL] Copyright (c) 1986-2011 by Cisco Systems,
[Code]......
just got new hardware and decided to try the newer USB port for IOS upgrades. I could not get the switch to recognize my 2gig flash drive. Do I need a proprietary stick or special format?
I also noticed when I removed it the switches crash dump and rebooted?
I am trying to configure Cisco SG300-52 switch for the first time and stuck without CLI configuration option. The configuration can be done using GUI, however, configuring using CLI would be more comfortable (as I am used to work with CLI of other Cisco switches)..
I was able to lo gin to switch using SSH, but the CLI appears in MENU format and was not able to find any way to go to CLI mode.
As per some blogs, in SG300 switches CLI mode can be accessed using Ctrl + Z in Menu, which did not work either in my case.
Switch is running with latest firmware version Sx300 Firmware Version 1.2.7.76.
I am updating the iOS for a 4948 the bootflash is empty so all i can get into is the rommon. There is no option for x-modem. How can I put the iOS onto this device? [code]
View 2 Replies View RelatedWe have a Cat2960-S Series PoE+ currently running 12.2(55) SE5 ios with SW image C2960S-UNIVERSALK9-M.We want to upgrade the ios to the lastest version but found there are 2 version: 12.2(53) SE2 and 15.0(1) SE.Which is the best & suitable for upgrade?
View 3 Replies View RelatedI have a very simple setup containing 3 C2960S switches:switch 1: central switch, acting as router between VLAN 1 en VLAN 2switch 2+3: edge switches, connected via 1 link to central switch, both on VLAN 2,Clients connect to switch 2 and 3 using dhcp, switch 1 uses dhcp relay to forward requests from VLAN 2 to the dhcp server on VLAN 1. So far so good.Now I want switch 1 to add option 82 to the dhcp requests so the dhcp server can see whether the request came through switch 2 or switch 3. I tried turning on dhcp option 82 support on switch 1 by doing.
View 2 Replies View RelatedWhy rpr is the only available redundancy mode option available to me. I'm running a 4507R+E with twin SUP7-E's.
Abbreviated show ver Cisco IOS Software, IOS-XE Software, Catalyst 4500 L3 Switch Software (cat4500e-UNIVERSALK9-M), Version 03.03.01.SG RELEASE SOFTWARE (fc2)Technical Support: [URL]/techsupportCopyright (c) 1986-2012 by Cisco Systems, Inc.Compiled Sun 26-Aug-12 13:45 by prod_rel_team
ROM: 15.0(1r)SG2gp08401 uptime is 6 weeks, 6 days, 4 hours, 59 minutesUptime for this control processor is 6 weeks, 3 days, 2 hours, 21 minutesSystem returned to ROM by RPR SwitchoverSystem image file is "bootflash:/cat4500e-universalk9.SPA.03.03.01.SG.151-1.SG1.bin"Jawa Revision 7, Snowtrooper Revision 0x0.0x1C
[code]....
In RFC 951, the format of BOOTP packet was legislated, but the vendor information was not legislated in this document, so the authors of this document had described that :"If the 'vend' field is used, it is recommended that a 4 byte 'magic number' be the first item within 'vend'. This lets a server determine what kind of information it is seeing in this field. "
I think it meant that the format of vendor information wasn't fixed in RFC 951, and any vendor can legislate a new format of vendor information by itself. And the value in "magic cookie" can be set by any vendor.But in RFC 2131, the format of DHCP packet was legislated, and the "magic cooke" was fixed to values 99, 130, 83 and 99, I think it meant that the format of option information in DHCP packet was fixed absolutely and any vendor can't legislate a new format by itself.
Since the format of option information in DHCP packet was fixed absolutely, why the network device needs "magic cookie" to identify the mode in which the succeeding data is to be interpreted ? I think the magic cookie is not useful in DHCP packet because the format of option information is fixed. In other words, there is only one format of option information forever.
I ran into problem with design that was prepared for Catalyst 6500, but in the meantime infrastructure got upgraded to Nexus. I have two datacenters connected with 1Gbit line (point-point), both ends of this circuit are N7K. There are few segments (like LAN, DMZ, PUBLIC) in separate VRFs in each DC and intention was to carry over these segments between locations using VPNv4 exchange via BGP. Each location have its own AS number and IPv4 BGP session is running between them (for global routing table at the moment). I tried to add VPNv4 to that peering session, but got message it is not supported in NX-OS for eBGP. Tried to find some more info about such limitation, but failed.
Before I start explore other options like Option A (creating subinterfaces per VRF and running separate IPv4 BGP session in each).
we have 6500 series switches by default all port channel loadbalancing is src-dst-ip.Now we have a requirement to change LACP load balance method to src-dst-port.
1) If we change LACP loadbalance method whar are the effects we are going have on our core network and all the existing servers
We have 2 x C6506E and 2 x C3560-48's, they are all interconnected via port channels at 2Gb per channel. The 6506's are running CEF but the 3560's are not (The 3560's carry all our server traffic).When I do a show CEF on the 3560's it says %IPv4 CEF not running. There does not appear to be a global command to enable CEF on these switches.Is this an IOS version option or is not supported on the hardware platform?
View 3 Replies View RelatedI am trying to configure a 4507 R chassis with Dual SUP but i cannot see teh switchpot mode trunk encapsulation dot1q?
I have typed:
interface GigabitEthernet5/1
description DOWNLINK toxxxxxx
switchport mode trunk
channel-group 11 mode on
!
I have have searched all other commands and sub-commands but could only find dot1q-tunnel which I beleive is for QINQ or some QoS featues and lot for L2 encapsulations?
the puzzling is:
XXX-Core4507#sh int gi5/1 trunk
Port Mode Encapsulation Status Native vlan
Gi5/1 off 802.1q notrnk-bndl 1
(Po11)
when I connect the dostribution switch a 3507 to this int gi 5/1, both interfaces do come up?
is it easy to remove the 3750x stacking? i'd like to test one of them on a sunday and keep the other one on production. it's just two stack of 3750x, is it hard and do i really need to remove the cables on the back?
basically i need to put a different config for my testing, i gues i need to remove the cables right? and put it back on the stack before monday.
Have a client wanting to hand out public ip addresses to all clients from a PFSense Firewall terminating the internet connection.
How do I allow the Cisco Switches currently in place, configured with private ip addresses in the 10.10.x.x ranges and Vlans, where the main 3550 layer 3 has defined dhcp scopes for each vlan, to relay dhcp requests from all vlans to the PFSense firewall?
I assume I would take off the currently defined dhcp scopes for the vlans and configure each vlan/switch with the ip helper address and specify the PFSense firewall and that Nat would have to be disabled onthe firewall?
if the Cisco Switches in my enviorment can support WCCP?
View 1 Replies View RelatedJust bought this switch it has the IP base IOS and I need to use BGP and VRF-lite. My question is can I configure and use these two things without having to upgrade to the IP Services IOS?
View 5 Replies View RelatedI have a DIR-615 rev C with firmware 3.10 and am trying to setup static routing. There is no option to select LAN for the interface
View 7 Replies View RelatedI am finding the power consumption of WS-C3750X-24T-L, WS-C3750X-48T-L, WS-C3560X-48T-L and WS-C3560X-24T-L switches?
View 5 Replies View RelatedI got new task moving WS-3560X24 port layer 3 core switch from one branch to be moved to my branch and connect WS3560 layer 3 core switch my site network. Both core switch has got 3-4 cisco 2960 switch underneath and lots of vlan offcourse. I am thinking about creating etherchannel between these two switch.
View 2 Replies View RelatedI own a Nanostation5 Loco, and I have a router behind it.I would like to add a DHCP Lease to that router and do a port forward to the router.I can not find the DHCP Lease option in Nanostation settings, but if I choose to see DHCP Leases in "Extra info" on main page I can see some MAC and IP addresses there.When it comes to port forwarding, I fill the form slots with info, and when I press OK to save it a pop-up comes saying "Please fill out this field", a field for another forward rule.
View 3 Replies View RelatedAny problem while using SFTP option in ACS5.3.I am trying ot use host-key sync command but giving below error.
ACS/admin(config-Repository)# host-key sync
% Error: First character must be a letter
% Error: Invalid ip address or hostnameSOK-S12-ACS-1/admin(config-Repository)# host-key sync% Error: First character must be a letter% Error: Invalid ip address or hostname
As per documentation this command needs to be added directly.
Does the two listed POE switch ports on the 880 series routers are active out of the box (default) or is configuration or extra parts required as internet pictures appear to show what looks like a power connector new to the POE ports?
View 8 Replies View RelatedIn one of our regional office I want to terminate 2 Internet links on a single 2811 Router and use both the links as primary and backup to enable site to site VPN. This also gives redundancy option if primary link fails. The Router has total 3 FE ports.
Current setup is terminating one internet link only on the router and establish site to site VPN to our HQ
ISP_Router--------------ASA_Firewall---------------------L3_sw_3560--------------------users
I have installed cisco lms4.1, seems to berest all working fine. But am not finding a option to enable email seetings options to send reports. I have already set smtp servers, through whihc threshold alerts are trigering, but am unavle get best practice reports. as per document, email setting option is available under Reports>reports settings. But I cant see email setting option under report setting, only 'set report path' is available.
View 1 Replies View RelatedI see the WS-SVC-AGM-1-K9 was EOL Jan 2010 ,What is the suggested Product Migration Option? Also if any is using this WS-SVC-AGM-1-K9 I would like some feedback ,Our problem is listed below and we are wondering of the WS-SVC-AGM-1-K9 will work ?
Looking at the best option to detect attempts at cracking our SIP servers. We see connections from scanners on the internet trying to brute force SIP passwords reasonably often, and would like to be alerted to them happening. Essentially we see hundreds of SIP registration attempts or Invites from the same IP, and this is how we know it is dodgy.