I have a stack of 2 C3750-switches (WS-C3750G-24TS-1U) with IPBASE-firmware (12.2(52)SE).
When I ping to a machine (in this case a virtual one), the replies are always received on the port where the machine is connected, but on the port-channel connecting to the stack of the 'pinging device' the reply comes only for certain initiators, and not for all.
Setting:
Gi1/0/6: Device/Server I want to connect too ; defined as access port
Gi1/0/25 + Gi2/0/25, as Port-Channel 1: The location of the devices I connect (read as: the uplink to the stack of the PC's), defined for Dot1Q-trunking
Monitoring setup: Source ports: Both: Gi 1/0/6, Po1 (or Po1 replaced by both interfaces)
For the machines which can ping the server I see 2 echo (ping) requests, followed by 2 echo (ping) replies ... So once seen on the Po1, and once seen on the interface Gi1/0/6.
However for other machines, the 2nd reply is missing ; which must be caused by the dropping of these packets in the switch. At least, I my opinion this must be the reason... But I can't see any (change of) output drops at int Po1, nor at Gi1/0/6. The CPU doesn't seem to have high usage, and even then, I don't think the error would be constant, as it's always failing for some PC's, and never for others... (at least for a certain time, a few hours it can be constant, the problem dissapears from time to time).
We have 2 6513 switches with SUP720/PFC3A and various POE modules and a 6748-GE-TX facing our servers. Additionally, we have a 4Gbps portchannel trunk interconnecting the switches. We have approximately 300 Nortel IP 1140e phones in use between the two switches.For the purpose of call recording, we've attempted to mirror the voice vlan using various approaches and have been met with limited success. We mirrored the VLAN using tx, rx, and both. When using both we appear to get duplicate packets at the destination interface.We seem to lose packets completely going in one direction or another for a given call. Packets are lost before they get to the destination interface?
I have a problem to solve in our data center, see attached drawing. HW: Our core switches consists of two stacked C3750 with ip routing. What I want to do is probably simple but I haven't been able to figure out the best method.
VLAN10 and VLAN20 should not be able to communicate with each other. (ACLs?)VLAN10 will have it's own default route/firewall. Both VLAN10 and VLAN20 should be able to send server backups to server in VLAN30. All 3 V LANs come in on a trunk from a pair of stacked C2960-S. I need it to be able to scale if we have 50 VLANs for instance, hopefully without long complicated ACLs. I've been considering VRF's, PBR but can't decide what's the simplest solution to this problem. I have never done this before so I would prefer to start off on the right foot.
I am having troubles to get 2 C3750-X switches WS-C3750-X-48P-L) to stack. They are both running iOS 15.0(2)-UNIVERSALK9, and are licensed for IP Base.
If I connect stack port 1 of switch 1 to stack port 2 of switch 1, and stack port 1 of switch 2to stack port 2 of switch 2 I get the following:
WS-C3750-X_STACK1_SW1>show switch stack-ports summary Switch#/ Stack Neighbor Cable Link Link Sync # InPort# Port Length OK Active OK Changes Loopback Status
[Code].....
I have tried restarting (powering off for about 1 min and turning back on) simultaneously, and powering off switch 1 for 1 min and switch 2 for 2 min. I have also tried both enabling the stack ports, and disabling followed by enabling.
I have a cable from an SFP module in a WS-C3750-48P with 12.2(55)SE1 running to a Gigabit port on a Cisco WLC. After the switch recovers from a power failure, the gigabit autonegotiation fails. The cure is a long drive to unplug and reseat the SFP. Note this happens at too many similar sites for this to be a loose connection. Interface shutdown then 'no shutdown' is not sufficient. The state is 'line protocol is down (not connected)'. Interface is configured for switchport mode trunk (auto speed, auto duplex). Command 'switchport nonegotiate' makes no difference. Is there a more powerful command than 'shutdown' which might toggle the interface signals? Is there some way of resetting the SFP? sh int gi 1/0/1 displays 'media type is 10/100/1000BaseTX SFP' and zero packets received.
I would like to apply policing on a C3750 interface, for all traffic matching 10.0.0.0 / 8, except for sub net 10.0.0.0 / 24. I plan to apply the following configuration, with an ACL that denies 10.0.0.0 / 24 then accept 10.0.0.0 / 8. I am quite sure of the answer but need a confirmation about the following configuration correct ? (10.0.0.0 / 24 will be not blocked, and no policing will be apply on it?)
ip access-list extended TEST deny tcp 10.0.0.0 0.0.0.255 any eq 5000 permit tcp any 10.0.0.0 0.255.255.255 any eq 5000 [code]....
We have existing stack of 3 units of WS-C3750-48TS-S ( 100 mbps ports with Gigabot uplinks). with IOS as follows, Can we add WS-C3750G-48PS-S in this same stack (this is 48 Gigabit ports)?
We have several of these WS-C2960S-24PS-L running 12.2(55)SE5 C2960S-universalK9-M and need to upgrade to a better.IOS since we have a sitution where CPU would get to 100% but we have only a few ports connected.Also we have several of WS-C3750-48P running 12.2(55) SE6 C3750-IPBASEK9-M.
According to cisco manual in order to change SDM template i need to reboot switch, but when i have C3750-X stack do i need to reboot stack or maybe will be enough reboot in sequence the stack members?
We are deploying the ISE MAC address authentication by-pass (mab) feature in our network as an alternative to port security on the switch port. Works well except for certain devices e.g. printers, snmp modules, and Unix/Linux Operating systems which can range from 5-10 minutes to never in authentication/opening the port.
can i stack cisco (ws-c3750G-12s) with (ws-c3750X-24p-poe-s) with (ws-c3750-48p-10/100 poe) i mean even a switch is 10/100 and the other switch is 10/100/1000?
Is it possible to upgrade a c3750-stack one member at a time to avoid downtime? I need to keep L3-functionality up.
If I have one etherchannel from access-switch (2 channel-ports in 3750, in different stack-members), my 3750-stack as a distribution layer switch, and another etherchannel (also spread over multiple stack members) to core, can I upgrade the entire stack without traffic interruption?
We have a bunch of switches that are running fine but the running-config file is missing and we can't save the config to the tftp server. IOS is c3550-ipbasek9-mz.122-37.SE1. I've got lots of these switches running the same code that are just fine.
a) I have three C3750-X switch stack together as my SAN switch and running on the new 15.0 release which is 15.0(1) SE.
b) Recently the master switch rebooted without any explanation. Create ticket with TAC and got an answer that it is due to a bug with ID: CSCtr31957.
My question is, which release that should i choose either the 15.0(1) SE3 or the latest 15.0(2)? Will it affect any of my configuration if i change to 15.0(2)?
Finally, what is the best practice to upgrade IOS in a stack whether to upgrade it 1 switch at a time or do it to all at once?
I have 8 switch stack consisting of six WS-C3550-48P and two WS-C3750G-16TD running software vesrion 12.2(25) SEB1. When I added new C3750v2-24PS (running image 12.2(50) SE5) in stack so I up-graded the image of existing 8 switches with latest veriosn 12.2(50) SE5. Once I have done with the upgrade then all ports of my stack switches went down after around five minuts. Is it image compatibility issue with existing switches or something else?
Our client having one c3750 with ipbase license switch.They are connected server and end switches to that switch.Our customer want to increase the speed to accessing the server at that time I am told to use etherchannel.Customer happy about this and implement the etherchannel configuration.Now i need to configure etherchannel upto 4 physical link.server are connected on port no Ge1/0/10,they want to bind four phical link GE1/0/10-13.how to configure etherchannel in this switch?
we recently had on our network a simple layer 2 loop problem, with big effects.Here is the situation: we have a C3750 switch, with STP activate on all ports.We don't have total control on this switchs, and for some reasons, it is possible that people connect a 2d switch on it (Cisco or non-Cisco).What happened several times is a classic case: a person interconnect 2 ports of this 2d switch, creating a loop. As the loop is created on the 2d switch only, the 1st switch detect no loop, the the uplink port keeps up.Afer this loop created, a broadcast storm occurs through the link between 1st & 2d switch .. and the storm propgates all over the LAN.I try to find some solutions to avoid that. One thing I would like to do is to find a mecanism on the first switch, which can permit to block the uplink port on the 1st switch if it sees the same MAC address as source in the 2 directions.Note that storm control, even configured to a quite low value (ie: 2Mbps) is not efficient enough to protect equipment (we have had big CPU impact on LAN equipments).
I have two layer 3 switches C3560 and C3750 Cisco switches with ios version "ipservices-mz.122-35.SE5".Now with the current ios version, these layer 3 switches are not supporting object group.so my question is , do i need to upgrade the ios, for this feature, if yes, which version ?
I have a new building to add to our campus and I have been encouraged to run single mode fiber. All of my other buildings are connected with multi-mode fiber. I just want to make sure i will not have an issue if I run single mode to the new building with SM SFP's.
We have WS-C3750-24FS switches stacked supporting users on our LAN. I want take advantage of the netflow capabilities of the WS-C3750X using the C3KX-SM-10G card.
Would I be to see netflow data coming from the WS-C3750's if I stacked it with the WS-C3750X?
Also I read that the C3KX-SM-10G card would support a 1G SFP is that correct?
Is there a way I can downgrade the firmware on a C3750 v2 switch 24TS-S v07 to 12.2(35) SE5. I have added this new switch to an existing stack but the FW is not compatable. I believe the answer is to upgrade the rest but I cannot afford any down time as they are used to run a CCTV securiy network 24/7. I have included details below to assist with my problem. Switch 4 is the one with a version miss match.
LNB-SWI3750-CTR-01#show verCisco IOS Software, C3750 Software (C3750-IPBASE-M), Version 12.2(35)SE5, RELEASE SOFTWARE (fc1)Copyright (c) 1986-2007 by Cisco Systems, Inc.Compiled Thu 19-Jul-07 19:15 by nachenImage text-base: 0x00003000, data-base: 0x01080000 ROM: Bootstrap program is C3750 boot loaderBOOTLDR: C3750 Boot Loader (C3750-HBOOT-M) Version 12.2(25r)SEE4, RELEASE SOFTWARE (fc1) LNB-SWI3750-CTR-01 uptime is 19 weeks, 3 days, 22 hours, 46 minutesSystem returned to ROM by power-onSystem image file is "flash:c3750-ipbase-mz.122-35.SE5/c3750-ipbase-
we are having trouble with the VPC, and etherchannel ? looked at many forums not to clear on wich one to use, this is are config, we have been getting alot of loops and kills are entire network
nexus switch config, this is on both nexus we have 2 of them at this site, that talk back to 2 other ones back to another site
I have stacked WS-C3750E-24PD with Ten Gigabit Ethernet ports configured under ether-channel. It has c3750e-universalk9-mz.122-55.SE1.bin IOS installed on it. One of the Ten Gigabit Ethernet ports, goes to err-disable mode with following errors on that specific ports.
I can't seem to find any info on how to configure 2 DHCP server pools on a C3750, to use with 2 user vlans. The purpose is that users in vlan 1 should get an IP address from DHCP server1, and users in vlan 2 should get an IP address from DHCP server2. Both DHCP servers are configured in a stack of C3750 switches, which acts a a L2 switch.
I have upgraded a C3750G-12S-E to c3750-ipserviceslmk9-tar.122-55.SE5This switch is a distribution layer switch for one of my remote sites. it contains an ip helper-address on the site vlan's SVI.DHCP relay is no longer functioning for client PCs. Static address assignment allows full network functionality. I enabled debug ip dhcp server packet. [code] Actually I am betting you upgraded your IOS from something before 12.2(50)SE to 12.2(50)SE or later. We added enhancement CSCso19800 which will validate DHCP options when we are a relay agent.
In our company 3nos Cisco 3750 (WS-C3750-48P) access switch in stake mode. All port are assigned with voice and data Vlan also Avaya IP connected with this switches. From last few days tow port 2/0/7 and 2/0/8 is showing amber and status is showing err-disable. At Avaya end it is showing a message “ETHERNET WAITING” in phone dispaly. I try to connect laptop directly with these ports but it is showing "Cross Connectivity". [code]