Cisco Switching/Routing :: Catalyst 4948 Power Error Message

Dec 20, 2010

We are running a small network business and as funs of ciscos we own a some of the 4948s.We are facing an issue with couple of them as we get the below error message

C4K_CHASSIS-3-INSUFFICIENTPOWERSUPPLIESDETECTED:Insufficient power
supplies present for specified configuration

First thought to replace the power supply didn't actually work as we did that with no result.Power consumption is not an issue as well because all other 4948s work fine with 1 power supply (forgot to mention is 1 power supply in all of them).

View 6 Replies


ADVERTISEMENT

Cisco Switching/Routing :: Sequence Error On Catalyst 4948-10GE Fiber Links

Apr 14, 2013

we have multiple Video production networks, with Video servers (AVID Unity ISIS) connected by 10GE fiber links to 4948-10GE switches. On almost every of these switches, I see more or less "Sequence-Err" interface errors. We do not currently have a known problem because this, and no other errors are seen. But I would like to understand the error, and therefore I would like to find out, what a sequence error means, what the cause is, and what the impact (to a frame) is?
 
By the way, it is well-known that the ISIS Video server does generate very excessive UDP data bursts. Maybe this matters? On Cisco doc I did not find an answer. The document "Troubleshooting Switch Port and Interface Problems" does unfortunately not refer to "sequence-err".
 
Here is an example output: 
WS-C4948-10GE#sh int t1/49
TenGigabitEthernet1/49 is up, line protocol is up (connected)
[code].....

View 2 Replies View Related

Cisco Switching/Routing :: Etherchannel Suspended Between Catalyst 4948 And VSS 6506E

Dec 23, 2012

I describe an issue when i need to performe an L2 or L3 Etherchannel from a Catalyst 4948 IOS Enterprise and 2 xCatalyst 6506E bandled with VSS.
 
From the VSS Side when i plug cables i see on the physicals and Etherchannel that Physical and protocole layer are up. On the 4948 side, I see that physical layer is up and protocol and Etherchannel interfaces are down.
 
On the Etherchannel port summary i see that the port state is supended.
 
On the first attempt, i have test with a L3 etherchannel on both side using no switchport with two IP addresses one at each side on etherchannel interfaces.
 
The etherchannel are bundled with LACP mode active and on the second attempt with PAGP mode ON. 
 
The same configured on VSS 6506E work fine with Catalyst 3560E.

View 3 Replies View Related

Cisco Switching/Routing :: Switch Connecting Catalyst 4948 To 3750

Jan 5, 2011

I have got a new 48port Cisco catalyst 4948 switch, which I configured as a VTP client and connected to Cisco 3750 which is a VTP Server (this switch is on production network). I connected port g1/0/48 from 3750 to port g1/48 on 4948 through a straight cable and made both ports as trunk port (I also tried through cross cable). The problem is these two switches are not detecting. For testing I connected a PC directly to one of the port on 4948 (making that a switch port) still the LED on switch didn’t glow up. Is there any special command needs to be run on 4948 switches to activate its physical ports?

View 7 Replies View Related

Cisco Switching/Routing :: Difference Between Catalyst 3750-X And 4948-10GE?

Jun 6, 2011

I want to choose a pair of switches for our data center.What I need: 48 x 1GE access ports, 2 x 10GE uplink ports.Nice feature of 3750-X is stacking. So what features has 4948-10GE? Why I should prefer that switch?

View 11 Replies View Related

Cisco Switching/Routing :: Catalyst 4948 Drops Truncated Packets?

Jan 4, 2012

I'm using a Catalyst 4948. It seems to drop all truncated packets. I don't know whether this is an expected behavior.I'm developing a program which processes packets in the following steps:

1) capture packets
2) if a packet is too long, truncate it to a certain length
3) insert a vlan tag (say 100) to each packet
4) send them to the switch
 
Mac address learning is disabled on the vlan 100, so the packets should be seen at all ports of the vlan. However, I only observed untruncated packets. Truncated packets seemed to be dropped by the switch.The summary of the source port is:
 
c4948-01#show interfaces gigabitEthernet 1/22 summary
......
Interface               IHQ   IQD  OHQ   OQD  RXBS RXPS  TXBS TXPS TRTL
-------------------------------------------------------------------------
* GigabitEthernet1/22      0     0    0     0 4018000  7390  2000    3    0
 
The receiving speed was approximately equal to what I sent.The summary of another vlan 100 port is:
 
c4948-01#show interfaces gigabitEthernet 1/18 summary
......
Interface               IHQ   IQD  OHQ   OQD  RXBS RXPS  TXBS TXPS TRTL
-------------------------------------------------------------------------
* GigabitEthernet1/18      0     0    0     0     0    0  3000    4    0
 
Almost no packets were output.I see a Cisco document says "ingress port drops corrupted packets" [URL] then my questions are:
 
1) Is this the root cause of dropping truncated packets?

2) What criteria does a switch use to check corrupted packets? My understanding is that truncated packets could have wrong L3 and L4 data, but they can't be detected at L2.

3) If switch drops mal-format packets, can we disable this feature?

View 2 Replies View Related

Cisco Switching/Routing :: Getting Error In 4948 Switch

Mar 13, 2013

My cisco 4948 switch is generating the below error,how do i troubleshoot this error.

*Mar 13 00:09:33.451: %C4K_L2MAN-6-INVALIDSOURCEADDRESSPACKET: (Suppressed 14 times)Packet received with invalid source MAC addre ss (00:00:00:00:00:00) on port Gi1/37 in vlan 1Gi1/37- to this port another 2950 switch is connected by trunk link.and to this switch end host is connected i.e.thin client

View 3 Replies View Related

Cisco Switching/Routing :: Message Error With C3750-I5-M

Jan 2, 2008

I have this system: IOS (tm) C3750 Software (C3750-I5-M), Version 12.1(19)EA1d, RELEASE SOFTWARE (fc1
 
An error appear in console (many times in one minute):
 
Jan  3 16:25:37: %LINK-3-BADMACREG: Interface StackPort1, non-existent MACADDR registry for link 0
-Process= "<interrupt level>", ipl= 4
-Traceback= 20A364 187F04 58D6FC 58B950 2D7CE0 2E00C8 2E2BEC 2E2F24 2B0BF8
 
What is the problem? What is the solution?

View 2 Replies View Related

Cisco Switching/Routing :: Error Message On CAT4507

May 8, 2011

I've taken 2 4507's fresh out of the box running CAT4500E-ENTSERVICESK9-MZ.122-53.SG2.BIN which was upgraded from CAT4500E-IPBASEK9-MZ.122-53.SG2.BIN
 
I'm getting constant %C4K_S2W-4-WRITECALENDARERR:  Calendar write operation Failed errors on the console.  I was also getting them on the original IOS version.
 
Anything I've seen say's to ignore them but their very frequent filling up the logs.
 
There's very little return on google and no bugs to report on Cisco?

View 8 Replies View Related

Cisco Switching/Routing :: Nexus 7009 Error Message

May 27, 2013

I have in logs following error message:

%DEVICE_TEST-2-PWR_MGMT_BUS_FAIL: Module 1

Has failed test SpineControlBus 20 times on device Power Mgmt Bus on slot 10 due to error Spine control test failed error number 0x00000002.

View 3 Replies View Related

Cisco Switching/Routing :: Ambiguous Error Message On Cat6500 VSS

Nov 15, 2012

I get a unclear log entry in a VSS system.

Me_Kr #1        ME_KR_ERROR_CNT_LTL_PARITY_ERR_ITRP_0_0[01C8] : INTR= 0001 MASK= 0001
Me_Kr #1        ME_KR_ERROR_CNT_LTL_PARITY_ERR_ITRP_0_0[01C8] : INTR= 0001 MASK= 0001
Me_Kr #1        ME_KR_ERROR_CNT_LTL_PARITY_ERR_ITRP_0_0[01C8] : INTR= 0001 MASK= 0001
Me_Kr #1        ME_KR_ERROR_CNT_LTL_PARITY_ERR_ITRP_0_0[01C8] : INTR= 0001 MASK= 0001

[code]....

View 1 Replies View Related

Cisco Switching/Routing :: 3750 - Error Message While IOS Upgrade

Jan 6, 2013

Have a small stack of two 3750 routers.  Get the following error message every few secounds:
 
%STACKMGR-4-STACK_LINK_CHANGE: Stack Port 1 Switch 1 has changed to state DOWN
%STACKMGR-4-STACK_LINK_CHANGE: Stack Port 1 Switch 1 has changed to state UP
 
Now I replaced the stacking cables but no joy. It was ok for an hr or so but then the error messages popped up again. Also random links on this stack back to access layer user switches have been going up and down randomly. So I have decided to take the next step and upgrade the IOS.
 
 Although when I try and copy a new IOS I get the following error:
 
%Error writing flash:/c3750-ipservicesk9-mz.122-55.SE6.bin (No space left on device)
 
Seems this image is 130MB while the image that is currently on it is 74MB and free space is 54MB. How do I get the image onto the router? If I delete the current image from flash will that cause the router to stop functioning?
 
Also I noticed there seems to be more than one flash directory. See below:
 
copy tftp: ?
  flash1:         Copy to flash1: file system
  flash2:         Copy to flash2: file system
  flash:          Copy to flash: file system
  null:           Copy to null: file system
  nvram:          Copy to nvram: file system
  running-config  Update (merge with) current system configuration
  startup-config  Copy to startup configuration
  system:         Copy to system: file system
  vb:             Copy to vb: file system
 
The current router image seems to be in flash1 and flash 2 also. Could I delete the image from flash1. Upload it there and then boot the router from flash1?

View 16 Replies View Related

Cisco Switching/Routing :: 6500 MSFC2 Strange Error Message

Jun 5, 2011

my MSFC2 sent this strange log message. %DATACORRUPTION-SP-1-DATAINCONSISTENCY: copy error, The error message decoder tool says: "NOT FOUND". The level is "alert".

View 8 Replies View Related

Cisco Switching/Routing :: 3750 - VLAN Flapping Error Message

Sep 15, 2012

I recently upgraded my network to have two 3750x core, one interface on the Cisco is connecting to a Net gear switch via a fiber converter. I am keep getting the vlan flapping error message in my log as below.
 
003396: Sep 17 01:46:16.328: %SW_MATM-4-MACFLAP_NOTIF: Host 5c0e.8ba7.0a5c in vlan 2 is flapping between port Gi2/0/15 and port Gi2/0/13
003397: Sep 17 01:46:19.843: %SW_MATM-4-MACFLAP_NOTIF: Host 5c0e.8ba7.0a5c in vlan 2 is flapping between port Gi2/0/15 and port Gi2/0/13
003400: Sep 17 01:49:58.769: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/17, changed state to down
[Code] .....
 
After my research i think this is a looping issue but I'm unsure how to address it.

View 2 Replies View Related

Cisco Switching/Routing :: 2800 - Does Not Boot And Shows Error Message

Sep 8, 2012

I have a Cisco 2800 series and it doesn't boot, only shows this message in the CLI> 

Bad RAM at location 0xA0000304: wrote 0xA0000304, read 0xA0000004
 
What means this? I have to change the RAM?

View 2 Replies View Related

Cisco Switching/Routing :: Error Message Ports Flapping On 3750 Stack

Aug 27, 2012

I am receiving the following error message on a Cisco 3750 switch stack. Need troubleshooting this error message.

00:03:13: %SW_MATM-4-MACFLAP_NOTIF: Host 00d0.7400.2730 in vlan 600 is flapping between port Gi2/0/3 and port Gi2/0/2

View 3 Replies View Related

Cisco Switching/Routing :: 6509 / Mac Address Error Message No Entries Present

Dec 6, 2012

I am receiving this error after connecting a copper adapter on a GBIC blade in a 6509. Here are the results from the show Interface.  I am waiting to confirm the device on the other side settings but as far as I see I get UP and Up for protocol and line respectively.
 
GigabitEthernet2/11 is up, line protocol is up (connected)
Hardware is C6k 1000Mb 802.3, address is 0009.11e4.f3ce (bia 0009.11e4.f3ce)
Description: RCPBSDEV
MTU 1500 bytes, BW 1000000 Kbit, DLY 10 usec,
reliability 255/255, txload 1/255, rxload 1/255
Encapsulation ARPA, loopback not set

[code]....

View 3 Replies View Related

Cisco Switching/Routing :: Nexus 7K Shows Continuous Tacacs Error Message?

Dec 10, 2012

I have Nexus 7K installations in 2 locations. Both of them have multiple VDCs. In default VDC there are continous tacacs error message though tacacs is not configured. The requests are from various public IPs where thsi VDC is not exposed to Internet at all. What would be t he cause of it?
 
%AUTHPRIV-3-SYSTEM_MSG: pam_aaa:Authentication failed for user root from 195.2.219.2
2012 Dec 11 16:25:28 IDC-FBDTB-AMR2-CN7K-01 %AUTHPRIV-3-SYSTEM_MSG: pam_aaa:Authentication failed for user nagios from 67.78.206.226
- sshd[25797]
2012 Dec 11 16:25:34 IDC-FBDTB-AMR2-CN7K-01 %AUTHPRIV-3-SYSTEM_MSG: pam_aaa:Authentication failed for user nagios from 67.78.206.226
- sshd[25799]

[code]....

View 1 Replies View Related

Cisco Switching/Routing :: NEXUS 7000 Octopus Internal Error In Device 78 Message?

Nov 12, 2012

NEXUS 7000 Octopus internal error in device 78 message. I got this on NEXUS 7000 logs:
 
 Nov 12 22:05:14 smale-outside : 2012 Nov 12 21:05:14 BRST: %MODULE-2-MOD_DIAG_FAIL: Module 2 (serial: JAF1548AMKB) reported failure on ports 2/1-2/32 (Ethernet) due to Octopus internal error in device 78 (device error 0xc4e0025b)
Nov 12 22:05:17 smale-outside : 2012 Nov 12 21:05:17 BRST: %MODULE-2-MOD_FAIL: Initialization of module 2 (serial: JAF1548AMKB) failed
Nov 12 22:05:18 smale-outside : 2012 Nov 12 21:05:18 BRST: %MODULE-2-MOD_FAIL: Initialization of module 2 (serial: JAF1548AMKB) failed

[code]....
 
I only have found:
 
[URL]
 
which does not match reality : No one was configuring Vlans.

View 5 Replies View Related

Cisco Switching/Routing :: Catalyst 3560-X Proprietary AC Power Cable

Jul 22, 2012

I just recieved a new 3560-x switch with the C3KX-PWR-715WAC. It looks like Cisco is now using a different AC power cable. Not the StackPower connector, but the standard AC power cable. My data center is setup to supply 208v using C13 power cables. The switch uses a C15 power cable, and comes with a standard NEMA 5 to C13 power cable. Does Cisco make, or officially support a C13 to C15 power cable? Can I still use a 208v power supply with these switches?

I'm using an APC AP8861 power distribution unit, see [URL]

View 1 Replies View Related

Cisco Switching/Routing :: Upgrading Catalyst 4500 Power Supplies?

Sep 19, 2012

If I'm upgrading dual redundant power supplies in a Catalyst 4507 from 1000W (data) to 1400W (data), can it be done without taking the switch through a power cycle? I'm guessing no as I read that the switch will not recognize a 1400W PSU in bay 2 if there is still an original 1000W PSU in bay 1.

View 2 Replies View Related

Cisco Switching/Routing :: Catalyst 3750X With PoE Secondary Power Supply Options?

Jul 21, 2012

When quoting a Catalyst 3750X with PoE (WS-C3750X-48P-E) the Dynamic Configurator Tool allows to include as the secondary power supply option the Catalyst 3K-X 350W AC Secondary Power Supply (C3KX-PWR-350WAC/2), but the default included primary power supply is the Catalyst 3K-X 715W AC Power Supply (C3KX-PWR-715WAC). My questions are the following:
 
1. Will this combination of power supply work?

2. Will the C3KX-PWR-350WAC/2 be able to power up the switch if the primary power supply of 715W fails?

3. Will the PoE will be lost if the primary power supply fails and only the secondary power supply of 350W keeps working?

4. If this secondary power supply of 350W is not suitable for PoE, why it is available as a secondary power supply option in the Dynamic Configurator Tool for a PoE switch?

View 4 Replies View Related

Cisco Switching/Routing :: Catalyst 4500 - Maximum Power Cable Length?

Feb 11, 2013

I am relocating UPS units and will need to buy longer power cables to extend from our 4506 and 4510 to the new location.I think I am looking at 15 to 20 feet but I am going to confirm. Is it okay to use longer cables?

View 9 Replies View Related

Cisco Switching/Routing :: When Connect Router 2821 Through Console / Get Error Message At Regular Interval Of Time

Feb 9, 2013

When  i connect  the Router   2821   through  the  Consol   get  error  message  at  regular  interval  of  time  %ENVMON-4-FAN_LOW_RPM: Fan 1 service recommended.

View 2 Replies View Related

Cisco Switching/Routing :: 3560 - Portable Redundant Power System For Catalyst Switches?

May 10, 2012

Does a portable RPS device either from Cisco or another manufacturer exists, that would allow you to move primary power for a switch without causing an outage? I realize that for the Catalyst 3560 for example, you can get an RPS 2300 or 675, but my understanding is that these are made for a more permanent installation, not to mention rather costly.
 
It looks like the RPS 675 is rather inexpensive after all, especially in the secondary market, but still rather large for toting around.

View 1 Replies View Related

Cisco Switching/Routing :: Power Supply Error Switch 3750

Dec 3, 2011

power supply problem...?Switch cisco WS-C3750-24P is showing "Unavail" from sh env all.Switch3750#sh env all FAN is OK,TEMPERATURE is OK,SW  PID,Serial#     Status Sys Pwr  PoE Pwr  Watts,Does it means that power supply 1 was removed? failed?,Do you know about another command to see more details?

View 3 Replies View Related

Cisco Switching/Routing :: PoE Error On 6500 / Inline Power Module

Feb 12, 2012

Cisco IP phones attached to a Moduke in one of my Cat6500 access Switches suddenly went down. Upon closer  inspection of the Switch Sys log, I observed the following Sys log error messages:   [Module 9 is experiencing the following error: Inline Power Module - PS Voltage bad. ]A sh Mod output indicates the PoE daughter card and Main Module are "ok" - see attached output. It appears issue is related to the the actual Power Supply module and not the blade module and installed PoE Daughter card. I am inclined to open a TAC case for a PS replacement, but wanted to see if this can be resolved without a hardware replacement. At this time all 48 IP phones attached to this module are out of Service.

View 2 Replies View Related

Cisco Switching/Routing :: 4510 Power Supply Error - PWR-C45-4200ACV

Mar 17, 2013

We are getting below errors on our Cisco 4500 Switche PS after Power Down activity.
 
Switch1
 
------------------ show power detail ------------------
 
Power                                             Fan      Inline
Supply  Model No          Type       Status       Sensor   Status
------  ----------------  ---------  -----------  -------  -------
PS1     PWR-C45-4200ACV   AC 4200W   good         good     good  
PS1-1                                off         
PS1-2                         220V   good        
PS2     PWR-C45-4200ACV   AC 4200W   err-disable  good     good  
PS2-1                         220V   good        
PS2-2                         220V   good        

*** Power Supplies of different type have been detected***
 
00:01:02: %C4K_CHASSIS-3-MIXINPOWERDETECTED: Power supplies in the chassis are of different types (AC/DC) or wattage(code)

View 1 Replies View Related

Cisco Switching/Routing :: Catalyst 6513 - Error / Module Failed SCP Download

Dec 8, 2012

I have a Cisco catalyst 6513 with sup720-3bxl and WS-X6724-SFP modules , the switch was working fine until yesterday ,but after a maintenance the modue WS-X6724-SFP failed to bring online , the error code is (Module  Failed SCP dnld) does it mean the module has hardware problem or i need to replace it ?

-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
ios version
s72033-adventerprisek9_wan-vz.122-33.SXH7.bin
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
show module
Mod Ports Card Type
Model           

[code]....

View 3 Replies View Related

Cisco Switching/Routing :: Catalyst 2950G - Putting Fa0/2 In Error-disable State

Mar 28, 2012

I have a Catalyst 2950G when I activate the switchport port-security, but I want to empty the black list of mac address because every time I connect a device, the port is automatically désacative, here is the port configuration:

!
interface FastEthernet0 / 2
  switchport access vlan 17
  switchport mode access
  switchport voice vlan 51

[code]....

I tried the following commands to clear the blacklist mac address of that port, but the problem is still relevant:

# Clear mac-address-table dynamic int fa0 / 2
# clear port-security all int fastethernet 0/2
# clear errdisable interface fa0 / 2 vlan

View 17 Replies View Related

Cisco Switching/Routing :: Cannot Boot IOS On Switch 4948

Jul 14, 2012

I cannot boot IOS, when i reload this switch it go to ROMMON. I try to uploand IOS but it still has problem. i think i may wrong some point during i did uploand.
 
This is problem
 
Switch#sh bootvar
BOOT variable = cat4500-entservicesk9-mz.150-2.SG3.bin,1;bootflash:cat4500-entservicesk9-mz.150-2.SG3.bin,1;bootflash:cat4500-entservicesk9-

[Code].....

View 2 Replies View Related

Cisco Switching/Routing :: 4948 Supported Stackable?

May 23, 2012

MAC Support: 16000
Backplane: 18Gbps
Forward: 28Gbps
VLAN's: 4000 (q-in-q support)
Jumbo Frame Supported
Supported 8000 static routing
!Supporting Stack!
 
Cisco 4948 supporting stackable? which product do you recommend to these criteria?

View 3 Replies View Related

Cisco Switching/Routing :: 4948 No Option For X-modem

Sep 19, 2012

I am updating the iOS for a 4948 the bootflash is empty so all i can get into is the rommon. There is no option for x-modem. How can I put the iOS onto this device? [code]

View 2 Replies View Related







Copyrights 2005-15 www.BigResource.com, All rights reserved