Cisco Switching/Routing :: Error Message On CAT4507
May 8, 2011
I've taken 2 4507's fresh out of the box running CAT4500E-ENTSERVICESK9-MZ.122-53.SG2.BIN which was upgraded from CAT4500E-IPBASEK9-MZ.122-53.SG2.BIN
I'm getting constant %C4K_S2W-4-WRITECALENDARERR: Calendar write operation Failed errors on the console. I was also getting them on the original IOS version.
Anything I've seen say's to ignore them but their very frequent filling up the logs.
There's very little return on google and no bugs to report on Cisco?
Have a small stack of two 3750 routers. Get the following error message every few secounds:
%STACKMGR-4-STACK_LINK_CHANGE: Stack Port 1 Switch 1 has changed to state DOWN %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 1 Switch 1 has changed to state UP
Now I replaced the stacking cables but no joy. It was ok for an hr or so but then the error messages popped up again. Also random links on this stack back to access layer user switches have been going up and down randomly. So I have decided to take the next step and upgrade the IOS.
Although when I try and copy a new IOS I get the following error:
%Error writing flash:/c3750-ipservicesk9-mz.122-55.SE6.bin (No space left on device)
Seems this image is 130MB while the image that is currently on it is 74MB and free space is 54MB. How do I get the image onto the router? If I delete the current image from flash will that cause the router to stop functioning?
Also I noticed there seems to be more than one flash directory. See below:
copy tftp: ? flash1: Copy to flash1: file system flash2: Copy to flash2: file system flash: Copy to flash: file system null: Copy to null: file system nvram: Copy to nvram: file system running-config Update (merge with) current system configuration startup-config Copy to startup configuration system: Copy to system: file system vb: Copy to vb: file system
The current router image seems to be in flash1 and flash 2 also. Could I delete the image from flash1. Upload it there and then boot the router from flash1?
my MSFC2 sent this strange log message. %DATACORRUPTION-SP-1-DATAINCONSISTENCY: copy error, The error message decoder tool says: "NOT FOUND". The level is "alert".
We are running a small network business and as funs of ciscos we own a some of the 4948s.We are facing an issue with couple of them as we get the below error message
C4K_CHASSIS-3-INSUFFICIENTPOWERSUPPLIESDETECTED:Insufficient power supplies present for specified configuration
First thought to replace the power supply didn't actually work as we did that with no result.Power consumption is not an issue as well because all other 4948s work fine with 1 power supply (forgot to mention is 1 power supply in all of them).
I recently upgraded my network to have two 3750x core, one interface on the Cisco is connecting to a Net gear switch via a fiber converter. I am keep getting the vlan flapping error message in my log as below.
003396: Sep 17 01:46:16.328: %SW_MATM-4-MACFLAP_NOTIF: Host 5c0e.8ba7.0a5c in vlan 2 is flapping between port Gi2/0/15 and port Gi2/0/13 003397: Sep 17 01:46:19.843: %SW_MATM-4-MACFLAP_NOTIF: Host 5c0e.8ba7.0a5c in vlan 2 is flapping between port Gi2/0/15 and port Gi2/0/13 003400: Sep 17 01:49:58.769: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/17, changed state to down [Code] .....
After my research i think this is a looping issue but I'm unsure how to address it.
I am receiving this error after connecting a copper adapter on a GBIC blade in a 6509. Here are the results from the show Interface. I am waiting to confirm the device on the other side settings but as far as I see I get UP and Up for protocol and line respectively.
GigabitEthernet2/11 is up, line protocol is up (connected) Hardware is C6k 1000Mb 802.3, address is 0009.11e4.f3ce (bia 0009.11e4.f3ce) Description: RCPBSDEV MTU 1500 bytes, BW 1000000 Kbit, DLY 10 usec, reliability 255/255, txload 1/255, rxload 1/255 Encapsulation ARPA, loopback not set
I have Nexus 7K installations in 2 locations. Both of them have multiple VDCs. In default VDC there are continous tacacs error message though tacacs is not configured. The requests are from various public IPs where thsi VDC is not exposed to Internet at all. What would be t he cause of it?
%AUTHPRIV-3-SYSTEM_MSG: pam_aaa:Authentication failed for user root from 195.2.219.2 2012 Dec 11 16:25:28 IDC-FBDTB-AMR2-CN7K-01 %AUTHPRIV-3-SYSTEM_MSG: pam_aaa:Authentication failed for user nagios from 67.78.206.226 - sshd[25797] 2012 Dec 11 16:25:34 IDC-FBDTB-AMR2-CN7K-01 %AUTHPRIV-3-SYSTEM_MSG: pam_aaa:Authentication failed for user nagios from 67.78.206.226 - sshd[25799]
The router 1841 is connected directly to the layer switch. the network diagram is below:
Office A --> Switch (L3) --> Router 1841 --> Internet --> Office B
However, when I transfer the file from Office A to office B, the speed very slow ( only around 40 kb/second), and there are an input error and CRC error:
Cisco-R1841#sh interfaces FA0/1 FastEthernet0/1 is up, line protocol is up Hardware is Gt96k FE, address is 0019.e02f.03dd (bia 0019.e02f.03dd)
I’m deploying new images on my switch 2960 24TT L. After installing the new image (c2960-lanbasek9-mz.122-58.SE1.bin) and reboot the switch I have always this error message : “Error loading "c2960-lanbasek9-mz.122-58.SE1.bin"
Interrupt within 5 seconds to abort boot process. Loading "flash:/c2960-lanbasek9-mz.122-58.SE1.bin"...@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@ ”
But the switch still boot well. Why do I have this error message?
LMS installed on Windows 2003. Backup fais with message "Backup failed.ERROR(1297): Fatal error: Database engine 'UPMDbEngine' could not be started on database 'upm' in Bulk mode.."
i am attaching the image which i recieved last night when i was assigning the IP but i got the error message which does not resembel to IP conflict error messsage
tying to connect CSM client to CSM server (ver 4.0) and getting attached error message. The server is running, no errors reported while installation, all services are up and fine. I tried to install client locally on the server and connect it that way with no luck. CSM server runs on Win 2008, firewall disabled.
As soon as I connected my ASR 1002s to the Internet and digested the Internet BGP table, I began receiving this message. I’ve google’d and turned up nothing so far. I assume I need to allocate more memory to this process.
We recently upgraded our any connect client from -2.5.3055 to -3.0.07059. This is running on a ASA HA pair running 8.4(2)8. Since the upgrade our users are seeing continual disconnects.
We have 2 Cat 6509 connected to 1 Gbps Ethernet WAN Link. On each 6509 we use 2 Gbps IPSec SPA Encryption cards for Encryption. The encrypted traffic goes to a GRE Tunnel. This morning I found some error messages in syslog.
Sometimes, either browsing from my computer, iPad or iPhone, I sometimes get a "can't connect to server" error, and it's not just a few forums here and there, it is a lot of them. But if I give them 5 or 10 minutes they will come. Imkmow that this isn't a normal up issue with sites servers actually being down. I thought it was a Google chrome issue, but it's been happening on safari. It hasn't started till we switched our Internet plan to 3mbps and a new router.
After making some physical changes to my home network (which had been running for sometime without incident) my desktop machine stopped (home built MSI X58 Platinum MB) talking to the network. I get "media not connected" even though I am connected, and the connection works for any other computer I attach. I get indication of proper physical connection at both ends (router and computer ethernet port), however I get no connection and the default 169 .... IP address. It does not matter if I create a fixed IP address in the router and set the ip address of the port to correspond. I have tried all the ip resets, stack resets, remove and reinstall the network ports, etc., to no avail. Connecting directly to the cable modem did not work. I even installed a new buss ethernet card with its own drivers and I get the same 'media not connected'.
OS: Windows 7 Home Premium -- Service Pack 1, 64-bit Browser: IE 9 Computer: Dell Studio 1745
I am receiving an error message window titled "Wireless Configuration" with the following message:
"OLE initialization failed. Make sure that the OLE libraries are the correct version."
I cannot find anything about updating OLE libraries in Windows 7. I have not installed any new software, and my computer is barely 2 years old. I do not find it a coinicidence that my free Dell tech support expired last month, and now I'm having issues with the Dell wireless card.
My laptop will not connect through my router anymore. I'm getting the message ( Cannot communicate with Primary DNS server (192.168.1.254). It works fine with an ethernet cable. I have a WII that uses the router also and I can watch a Netflix movie on it so the router seems to be working. My desktop computer is working fine through a DSL connection. The laptop is a Gateway and is running Vista.
I'm using "WS-C4948(12.2(54)SG)+PWR-C49-300AC/2". The following message are logged in the system log, but it was to check the status with the show command and status LED, but there was no abnormality. I thought the power supply has failed, but I seem different.
040861: Apr 27 07:00:50: %C4K_IOSMODPORTMAN-4-POWERSUPPLYBAD: Power supply 1 has failed or been turned off 040862: Apr 27 07:00:50: %C4K_IOSMODPORTMAN-4-POWERSUPPLYFANBAD: Fan of power supply 1 has failed
I checked.>> #show environment alarm no alarm #show environment status power supply Power Fan Inline Supply Model No Type Status Sensor Status ------ ---------------- --------- ----------- ------- ------- PS1 PWR-C49-300AC AC 300W good good n.a. PS2 PWR-C49-300AC AC 300W good good n.a.
I am having a problem with my cisco 3660 router. I have installed a wic 2T interface card and every time i set it to "no shutdown" the interface always went down and keep getting the following message " %FECPM-2-SCCFAIL: Init of SCC2 for int 0/0 failed to do fecpm_dma_init" .
I have cisco switch model WS-C3750G-12S-D. It is in transparent mode. I am getting below error message when tried to create new vlan.
Proposed configuration exceeds the limit of 1005 VLANs that can be supported on this platform. Reduce the number of VLANs proposed to be within this limit.
After deleting few unnecessary vlans, it allowed me to create.
3750#sh vtp statusVTP Version : running VTP1 (VTP2 capable)Configuration Revision : 0Maximum VLANs supported locally : 1005Number of existing VLANs : 959VTP Operating Mode : TransparentVTP Domain Name : VTP Pruning Mode : DisabledVTP V2 Mode : DisabledVTP Traps Generation : DisabledMD5 digest : 0xBC 0xA7 0xEC 0xDE 0x36 0x6C 0x61 0xB4 Configuration last modified by 97.193.17.172 at 0-0-00 00:00:00
I confused with terms 'maximum supported vlans' and 'maximum locally supported vlans'. If switch is supporting vlans 1-4094 means it should also allow to create locally. Otherwise how they will pass through the switch trunks without local creation.