my MSFC2 sent this strange log message. %DATACORRUPTION-SP-1-DATAINCONSISTENCY: copy error, The error message decoder tool says: "NOT FOUND". The level is "alert".
I've taken 2 4507's fresh out of the box running CAT4500E-ENTSERVICESK9-MZ.122-53.SG2.BIN which was upgraded from CAT4500E-IPBASEK9-MZ.122-53.SG2.BIN
I'm getting constant %C4K_S2W-4-WRITECALENDARERR: Calendar write operation Failed errors on the console. I was also getting them on the original IOS version.
Anything I've seen say's to ignore them but their very frequent filling up the logs.
There's very little return on google and no bugs to report on Cisco?
Have a small stack of two 3750 routers. Get the following error message every few secounds:
%STACKMGR-4-STACK_LINK_CHANGE: Stack Port 1 Switch 1 has changed to state DOWN %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 1 Switch 1 has changed to state UP
Now I replaced the stacking cables but no joy. It was ok for an hr or so but then the error messages popped up again. Also random links on this stack back to access layer user switches have been going up and down randomly. So I have decided to take the next step and upgrade the IOS.
Although when I try and copy a new IOS I get the following error:
%Error writing flash:/c3750-ipservicesk9-mz.122-55.SE6.bin (No space left on device)
Seems this image is 130MB while the image that is currently on it is 74MB and free space is 54MB. How do I get the image onto the router? If I delete the current image from flash will that cause the router to stop functioning?
Also I noticed there seems to be more than one flash directory. See below:
copy tftp: ? flash1: Copy to flash1: file system flash2: Copy to flash2: file system flash: Copy to flash: file system null: Copy to null: file system nvram: Copy to nvram: file system running-config Update (merge with) current system configuration startup-config Copy to startup configuration system: Copy to system: file system vb: Copy to vb: file system
The current router image seems to be in flash1 and flash 2 also. Could I delete the image from flash1. Upload it there and then boot the router from flash1?
We are running a small network business and as funs of ciscos we own a some of the 4948s.We are facing an issue with couple of them as we get the below error message
C4K_CHASSIS-3-INSUFFICIENTPOWERSUPPLIESDETECTED:Insufficient power supplies present for specified configuration
First thought to replace the power supply didn't actually work as we did that with no result.Power consumption is not an issue as well because all other 4948s work fine with 1 power supply (forgot to mention is 1 power supply in all of them).
I recently upgraded my network to have two 3750x core, one interface on the Cisco is connecting to a Net gear switch via a fiber converter. I am keep getting the vlan flapping error message in my log as below.
003396: Sep 17 01:46:16.328: %SW_MATM-4-MACFLAP_NOTIF: Host 5c0e.8ba7.0a5c in vlan 2 is flapping between port Gi2/0/15 and port Gi2/0/13 003397: Sep 17 01:46:19.843: %SW_MATM-4-MACFLAP_NOTIF: Host 5c0e.8ba7.0a5c in vlan 2 is flapping between port Gi2/0/15 and port Gi2/0/13 003400: Sep 17 01:49:58.769: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/17, changed state to down [Code] .....
After my research i think this is a looping issue but I'm unsure how to address it.
I am receiving this error after connecting a copper adapter on a GBIC blade in a 6509. Here are the results from the show Interface. I am waiting to confirm the device on the other side settings but as far as I see I get UP and Up for protocol and line respectively.
GigabitEthernet2/11 is up, line protocol is up (connected) Hardware is C6k 1000Mb 802.3, address is 0009.11e4.f3ce (bia 0009.11e4.f3ce) Description: RCPBSDEV MTU 1500 bytes, BW 1000000 Kbit, DLY 10 usec, reliability 255/255, txload 1/255, rxload 1/255 Encapsulation ARPA, loopback not set
I have Nexus 7K installations in 2 locations. Both of them have multiple VDCs. In default VDC there are continous tacacs error message though tacacs is not configured. The requests are from various public IPs where thsi VDC is not exposed to Internet at all. What would be t he cause of it?
%AUTHPRIV-3-SYSTEM_MSG: pam_aaa:Authentication failed for user root from 195.2.219.2 2012 Dec 11 16:25:28 IDC-FBDTB-AMR2-CN7K-01 %AUTHPRIV-3-SYSTEM_MSG: pam_aaa:Authentication failed for user nagios from 67.78.206.226 - sshd[25797] 2012 Dec 11 16:25:34 IDC-FBDTB-AMR2-CN7K-01 %AUTHPRIV-3-SYSTEM_MSG: pam_aaa:Authentication failed for user nagios from 67.78.206.226 - sshd[25799]
I keep getting log messages like the following on my router:[RV220W]Tue Aug 14 00:00:14 2012(GMT+0200) [RV220W][Kernel][KERNEL] BW_LIMIT_PKTS IN=LAN SRC=10.0.0.10 DST=173.194.35.134 PROTO=TCP SPT=1159 DPT=443,i.e. a large number of BW_LIMIT_PKTS messages regarding traffic from the LAN to the WAN destined to ports 53, 443 and 80 only. Is it related to QoS policies? What is the meaning of this message?
i have this message "DHCP Timeout"on few cisco IP Phones . try to assign IP manually and it's working fine.. seems DHCP not giving IP's to those.. 6500 have configured as DHCP pool.
Cisco IP phones attached to a Moduke in one of my Cat6500 access Switches suddenly went down. Upon closer inspection of the Switch Sys log, I observed the following Sys log error messages: [Module 9 is experiencing the following error: Inline Power Module - PS Voltage bad. ]A sh Mod output indicates the PoE daughter card and Main Module are "ok" - see attached output. It appears issue is related to the the actual Power Supply module and not the blade module and installed PoE Daughter card. I am inclined to open a TAC case for a PS replacement, but wanted to see if this can be resolved without a hardware replacement. At this time all 48 IP phones attached to this module are out of Service.
Nov 16 13:23:21.355: %SYSTEM_CONTROLLER-3-MORE_COR_ERR: 255 correctable DRAM memory errors in previous hour Nov 16 13:23:21.355: %SYSTEM_CONTROLLER-3-COR_MEM_ERR: Correctable DRAM memory error. Count 623, log 8053C830 Nov 16 14:23:21.340: %SYSTEM_CONTROLLER-3-MORE_COR_ERR: 255 correctable DRAM memory errors in previous hour Nov 16 14:23:21.340: %SYSTEM_CONTROLLER-3-COR_MEM_ERR: Correctable DRAM memory error. Count 879, log 8053C810
error on switch console every hour.
ios version : Cisco IOS Software, s72033_rp Software (s72033_rp-ADVIPSERVICESK9_WAN-M), Version 12.2(33)SXJ1, RELEASE SOFTWARE (fc2)
we recently updated all of our WLC's to 7.098 and it all went smoothly, controllers rebooted and AP's updated their firmware and rebooted OK.One WLC (4402) which was working fine since the update now has no AP's associated. The AP's were all configured to run in HREAP mode and are on remote sites within our WAN. I have checked that all policies and ports are still open (none have changed anyway) but the AP's can not join with the contoller.The log from an AP trying to join with the WLC.
[Code] .....
The logs on WLC show as below.
*emWeb: Jan 12 13:14:13.629: %AAA-5-AAA_AUTH_ADMIN_USER: aaa.c:1289 Authentication succeeded for admin user 'adann'*spamReceiveTask: Jan 12 13:14:12.919: %LWAPP-6-CAPWAP_SUPP_VER: spam_lrad.c:1440 Discarding discovery request in LWAPP from AP 00:21:a0:81:a4:10 supporting CAPWAP*spamReceiveTask: Jan 12 13:14:11.543: %LWAPP-6-CAPWAP_SUPP_VER: spam_lrad.c:1440 Discarding discovery request in LWAPP from AP 00:21:a0:81:8f:a0 supporting CAPWAP*spamReceiveTask: [Code] ......
Last week and just yesterday, our switch SG200 50/50 logged an error like this:
%CDP-E-MALFORMED_TLV: CDP message from 88:43:e1:ab:66:f8 cached with illegal Appliance VLAN-ID TLV
At the time of the error, the SA520 router's LAN Port 1 where the SG200 Port 49 connected went down. (Light is OFF) So internet is down and other V LAN are disconnected. The MAC address on the log is the SA520 router. This happens 2x now and it needs for me to reboot both switch and router. and goes back again online.
SG200 50/50 Port Firmware 1.1.1.8 SA 520 Firmware (Primary/Sec):2.1.51/2.1.18
The router 1841 is connected directly to the layer switch. the network diagram is below:
Office A --> Switch (L3) --> Router 1841 --> Internet --> Office B
However, when I transfer the file from Office A to office B, the speed very slow ( only around 40 kb/second), and there are an input error and CRC error:
Cisco-R1841#sh interfaces FA0/1 FastEthernet0/1 is up, line protocol is up Hardware is Gt96k FE, address is 0019.e02f.03dd (bia 0019.e02f.03dd)
I’m deploying new images on my switch 2960 24TT L. After installing the new image (c2960-lanbasek9-mz.122-58.SE1.bin) and reboot the switch I have always this error message : “Error loading "c2960-lanbasek9-mz.122-58.SE1.bin"
Interrupt within 5 seconds to abort boot process. Loading "flash:/c2960-lanbasek9-mz.122-58.SE1.bin"...@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@ ”
But the switch still boot well. Why do I have this error message?
LMS installed on Windows 2003. Backup fais with message "Backup failed.ERROR(1297): Fatal error: Database engine 'UPMDbEngine' could not be started on database 'upm' in Bulk mode.."
i am attaching the image which i recieved last night when i was assigning the IP but i got the error message which does not resembel to IP conflict error messsage
tying to connect CSM client to CSM server (ver 4.0) and getting attached error message. The server is running, no errors reported while installation, all services are up and fine. I tried to install client locally on the server and connect it that way with no luck. CSM server runs on Win 2008, firewall disabled.
As soon as I connected my ASR 1002s to the Internet and digested the Internet BGP table, I began receiving this message. I’ve google’d and turned up nothing so far. I assume I need to allocate more memory to this process.
We recently upgraded our any connect client from -2.5.3055 to -3.0.07059. This is running on a ASA HA pair running 8.4(2)8. Since the upgrade our users are seeing continual disconnects.
We have 2 Cat 6509 connected to 1 Gbps Ethernet WAN Link. On each 6509 we use 2 Gbps IPSec SPA Encryption cards for Encryption. The encrypted traffic goes to a GRE Tunnel. This morning I found some error messages in syslog.
Sometimes, either browsing from my computer, iPad or iPhone, I sometimes get a "can't connect to server" error, and it's not just a few forums here and there, it is a lot of them. But if I give them 5 or 10 minutes they will come. Imkmow that this isn't a normal up issue with sites servers actually being down. I thought it was a Google chrome issue, but it's been happening on safari. It hasn't started till we switched our Internet plan to 3mbps and a new router.
After making some physical changes to my home network (which had been running for sometime without incident) my desktop machine stopped (home built MSI X58 Platinum MB) talking to the network. I get "media not connected" even though I am connected, and the connection works for any other computer I attach. I get indication of proper physical connection at both ends (router and computer ethernet port), however I get no connection and the default 169 .... IP address. It does not matter if I create a fixed IP address in the router and set the ip address of the port to correspond. I have tried all the ip resets, stack resets, remove and reinstall the network ports, etc., to no avail. Connecting directly to the cable modem did not work. I even installed a new buss ethernet card with its own drivers and I get the same 'media not connected'.
OS: Windows 7 Home Premium -- Service Pack 1, 64-bit Browser: IE 9 Computer: Dell Studio 1745
I am receiving an error message window titled "Wireless Configuration" with the following message:
"OLE initialization failed. Make sure that the OLE libraries are the correct version."
I cannot find anything about updating OLE libraries in Windows 7. I have not installed any new software, and my computer is barely 2 years old. I do not find it a coinicidence that my free Dell tech support expired last month, and now I'm having issues with the Dell wireless card.