Cisco Switching/Routing :: Upgrading Line Cards - 4510R-E

Feb 4, 2013

I have a requirement to upgrade some line cards in our 4510R-E chassis to ease some oversubscription due to the 6Gbps limit.
 
At the moment my plan is to upgrade three cards from WS-X4548-GB-RJ45 to X4648 to get the 24Gbps per card.
 
Supervisors are 6-E
 
1. Is this a viable plan?

2. If so can the cards be hot-swapped?

3. Would the new cards retain the existing interface settings of the previous cards?

4. Any gotchas to look out for?

View 4 Replies


ADVERTISEMENT

Cisco Switching/Routing :: Moving Line Cards On 4510R-E?

Apr 2, 2013

We need to move some line cards around on our 4510.  The top slots have a 24Gbps backplane while the lower slots are limited to 6Gbps.  Poor planning on our part has left us with installing a 10Gb line card in one of the bottom slots.  I'd like to move a couple of the cards up top, to the bottom.
 
My question is simply will the switch magically preserve the configuration for those cards and change the slot number for me or will I need to reconfigure the interfaces for those cards I move?

View 2 Replies View Related

Cisco Switching/Routing :: 4500 Sup 6 / Not Seeing Line Cards

Feb 14, 2012

I have a Cisco 4500 Sup 6 engine and I have two 48 port fiber line cards installed. When I do a show interfaces I do not see any of the Fiber cards. This is a new out of the box 4500 and I installed the Sup 6 Line card in Slot #1, And the two 48 port Fiber cards in Slots 2 and 3. Am I missing something, is there a command or set up procidure for the line cards. I just assumed they were plug and play

View 2 Replies View Related

Cisco Switching/Routing :: Nexus 7000 OTV With F1 Line Cards?

Jul 17, 2012

I have two data centres connected via a L2 DWDM, my manager wants to look into using OTV to get rid of the layer 2 broadcasting issues.
 
Problem is the DWDM is 1000BaseSX, which is only supported on the N7K-F132XP-15.   (and the N7K-M148GS-11 but that doesn't support FCOE, so many bloody caveats). From what I can gather OTV is not supported on the N7K-F132XP-15.
  
Is it possible to terminate the DWDM on the F1 card & loop another port from the F1 to a port on the N7K-M148GT-11 & run OTV on the M1????
  
Either using VDCs or just an isolated VLAN on the F1. Is there any better way to do this? Hardware has not yet been purchased.

View 0 Replies View Related

Cisco Switching/Routing :: How To Know WOL Is Supported On N7K With 6.x Code And F2 Line Cards

May 11, 2012

I would like to know whether WOL is supported on a N7K with 6.x code and F2 line cards. I also would like a how to for this. If it is not supported will an ip helper address to the broadcast address of the destination vlan SVI will suffice to get it workinng. If so I can restricht the forwarded broadcast to only the wol traffic.

View 1 Replies View Related

Cisco Switching/Routing :: Does WS-X67XX Line Cards Support By Sup-2T VSS

Aug 29, 2012

I read the document,  [URL]
 
[
Q.I have Cisco 6700 Series line cards today with Centralized Forwarding Cards (CFCs). Are these line cards supported in a Cisco Supervisor Engine 2T system?
#
A. A Cisco Supervisor Engine 2T system will support all Cisco 6700 Series line cards with CFCs.
]
 
So, As long as the 67XX line card is using CFC, it is compatible with Sup-2T.
 
 I also find the IOS release note indicate the 6704-10G with CFC is supported by Sup-2T, but it require 512M memory.
 
[URL]
 
The bug details is not disclosed.  So I further search what the default memory size of the WS-F6700-CFC is, then I found here says it is only supported by Sup720 and no memory upgrade option, which means must upgrade to DFC4, in another words, it is not compatible with Sup-2T
 
[URL]
  
WS-F6700-CFC:
Centralized Forwarding Card (CFC) for use on WS-X67xx Ethernet modules. This daughter card is supported only by the Supervisor Engine 720. There are no memory options for this daughter card. default memory: 256M
  
So my question is: whether “WS-X6724-SFP with CFC” and “WS-X6704-10G with CFC” compatible with Sup-2T without upgrading to DFC4 daughter card, and do they support in VSS-2T?

View 4 Replies View Related

Cisco Switching/Routing :: Configure 6500 Line Cards Before Insertion?

Dec 7, 2011

Is it possible to configure the switchports on a 6500 linecard before it has been inserted?
 
So for example, I have a 6509 with slot 9 free. I'm going to install a 48 port line card. Is it possible to configure those 48 ports before the card is inserted?

View 2 Replies View Related

Cisco Switching/Routing :: Nexus 7009 Line Cards Compatibility?

Apr 14, 2013

I wanted to know that in nexus 7009, can i use mix of F2/M1/M2 series line cards ? will they work with each other ? Lets say i have F2 line card and M2 line card, will servers attached to them will communicate with each other ?

View 4 Replies View Related

Cisco Switching/Routing :: DFC3 For WS-X6724-SFP 6500 Line-cards?

Jul 17, 2012

When quoting a WS-X6724-SFP line card for a Catalyst 6500:

1. If no Distributed Forwarding Card 3 (DFC3) is selected, can it be purchased at a later time as a spare part or the client needs to buy the line card with the DFC3 included from start?
 
2. Does each line card require a DFC3 in order to be able to perform localized forwarding decisions?
 
3. Does the DFC3 card is embedded in the line card physically?

View 4 Replies View Related

Cisco Switching/Routing :: 4507 R + E Chassis With Classic Line Cards?

Jan 8, 2012

Client has Cisco 4507R+E chasis with SUP- 7L-E and he has WS-X4418-GB line card in stock can this line card work with E series chassis

View 2 Replies View Related

Cisco Switching/Routing :: 10G Line Cards Supported With 4503 SUP2+TS?

Nov 30, 2011

I need a 10G support on 4503 chassi with SUP II plus TS.Is any of the 10G line cards i.e. 4712 or 4606 supported on SUP II plus TS on 4503?

View 4 Replies View Related

Cisco Switching/Routing :: 6509 - Multiple Line Cards Down After Config

May 28, 2013

I recently changed the entire configuration on two 6509 switches, and the fibre modules on slot 7 and 8 have gone down on BOTH switches. It would be easy to say that its a hardware fault but I cannot understand how module 7 and 8 can go down on both switches. Initially I thought it maybe due to IOS bug 22-33.SXI2a.bin" so I upgraded it to s72033-advipservicesk9_wan-mz.122-18.SXF12a.bin but it still down.These are the actions I have carrried out to try resolve the issue:
 
- Reverted back to orginal configs but no luck
 
- Tried to use "power enable" command but the status light on both modules seems to turn red and then go off again.
 
- I have also tried to put one of the fibre modules into a different slot but no joy
 
- Upgraded the IOS from 22-33.SXI2a. to 122-18.SXF12a
 
I am sure that hardware fault cannot occur on BOTH modules 7 & 8 on BOTH switches after config change.The error in the log shows that modules "failed to bring online because of registration timer event". I understand this means that it is unable to download the image within the allocated time. [code]

View 7 Replies View Related

Cisco Switching/Routing :: 4500-E Series Line-cards Supported On 4507R?

Mar 25, 2013

I wonder are 4500-E series line cards (i.e. WS-X4648-GB-RJ45, WS-X4748-UPOE+E and WS-X4606-X2-E) supported on 4507R chassis? Datasheet says "Classic line cards may be deployed in both classic and E-Series chassis with either classic Cisco Catalyst 4500 Series supervisor engines or with the Cisco Catalyst 4500E Series Supervisor Engine." But it says nothing about E-Series line-cards being (or not) supported on classic chassis (like 4507R).

View 3 Replies View Related

Cisco Switching/Routing :: 6509 Configure QoS On Gig Line Cards That Have 1P3Q8T Queue Structure

Nov 3, 2011

I previously put this is the 'Video over IP' discussions group, which is not getting any response.I have a 6509 and need to configure QoS on gig line cards that have 1P3Q8T queue structure. I've already got the mls qos configured, and have the correct class maps built for Voice, Video, and Signalling.(I'm not doing autoqos). I have only four classes; voice, video, signalling, and default (best effort).I need to configure the commands on the individual gig ports for the appropriate bandwidths as shown below:
 
1. 300 VoIP G711 calls x 100kbs/call = 30mbs of priority queue  DSCP = EF (46) CoS = 5
2. 150 Video conference calls x 1.5mbs/call = 225mbs  DSCP = CS4 (32) CoS = 4
3. 450 Signalling x 13kps/call = 5.8mbs (round to 6mbs) DSCP = CS3 (24) CoS = 3
4. Default class is not marked  DSCP & CoS = 0

View 1 Replies View Related

Cisco Switching/Routing :: N7K-148GT-11L And N7K-F132XP-15 / Virtual Port Channel On Different Line Cards?

Jan 4, 2012

It is possible to add interface from different line cards reference ( for example N7K-148GT-11L and N7K-F132XP-15 ) to a vPC ? I ask you because I try it and I have the following error :
 
command failed: port not compatible [Capabilities FabricPath]

View 1 Replies View Related

Cisco Switching/Routing :: Putting PoE Line Cards Into An Existing 4506 (older Version)?

Jan 13, 2012

I have a number of existing 4506 chassis type switches (the older non -E version) that I would like to roll out IP phones to. Instead of replacing the entire chassis, I would like to just replace the line cards in the switches with WS-X4548-GB-RJ45V. What or how much power supplies should I have in each switch to be able to power the 5 poe line cards (each port per line card will power an ip phone)?

View 6 Replies View Related

Cisco Switching/Routing :: Install Line Cards (WS-X4548-GB-RJ45 / Chassis WS-C4510R-E) On Chassis Ws-6504-E?

May 15, 2012

we need to install a line cards (WS-X4548-GB-RJ45, chassis WS-C4510R-E), on a chassis Ws-6504-E.where I can find information about compatibility?

View 2 Replies View Related

Cisco Switching/Routing :: Configure NAT On A 4510R+E?

Dec 22, 2012

I notice that NAT is not possible Cisco Catalyst 4500e series. Is there any other ways to configure NAT? Currently we have 2x Catalyst 6509 and we're migrating to the 4510e and there's NAT in the 6509s. I was thinking of re-using the 6509s and connect to the 2 new 4510e in a meshed trunking layout with MST (Layer 2) and OSPF/EIGRP (Layer 3) protocols turned on.

View 1 Replies View Related

Cisco Switching/Routing :: Netflow On Cat 4510R+E With IOS-XE?

Feb 11, 2012

I am trying to figure out the Flexible Net-flow on Cat 4510R+E Switch running IOS-XE code. My Neflow flow software is manageengine 7.X. I am able to see the netflow interfaces but the traffic itself is not displayed. On the Switch I can see the netflow exporter statistics counter being incremented thereby confirming as being exported.

View 2 Replies View Related

Cisco Switching/Routing :: 4510R Can Still Use OM3 Patch Cable

Jan 21, 2008

We have a new building, and I told the cable company run OM3 cable from second floor to 1st FL data closet because we have 4510R SupV-10G at each floor.However, the cable company ran a regular fiber cable instead of OM3 mistakenly. My questions, can I still use OM3 patch cable??  Second questions, can I still have the 10Gig performance??

View 3 Replies View Related

Cisco Switching/Routing :: 4510R - SUP V-10GE Uplink

Jan 28, 2013

I have a two Cisco 4510R each with two sup V-10GE redundant. The code on these sup modules are 12.2(31r)SG3. I need some assistance in getting this setup worked out. I have all four of the 10GE populated with appropriate optics. I setup a link from one 4510R to the other using these interfaces. From the documentation I found I had to use Tengi1/1 and Tengi2/2 as the redundant pair. I plugged the up link into these ports. The Tengi1/1 (active supervisor) links up and works fine. But when I look at the ports port Tengi2/2 it isn't showing link or active. Now port 2/1 (nothing plugged into it) is showing as active.
 
Now is the redundancy supposed to be 1/1 and 2/1? If so, the switch is in production, when I move the connection over from 2/2 to 2/1 will it cause a outage? The reason for this is I now have a system with a 10G port and would like to utilize one of the other 10G ports. Is that possible? Or does it have to be a lag/redundant up link to work (say to another switch)?

View 2 Replies View Related

Cisco Switching/Routing :: Catalyst 4510R+E Supervisor 7-E SSO Not Available

Sep 22, 2011

I'm working on deploying a new 4510R+E for our organization.  This is my first experience with a modular switch.  I'm trying to enable SSO, however in the redundancy configuration mode, the sso command is not available.  Is SSO only available with certain software images / licensing levels? [code]

View 2 Replies View Related

Cisco Switching/Routing :: 4510R E High Cpu Utilization On One Core

Dec 13, 2011

We have cisco 4510R+E switch with IOS-XE Software Version 03.01.01.SG RELEASE SOFTWARE (fc1).Our this switch is having two core & one core is always going to about 90% to 98% cpu utilization while other core is showing normal (about 5% to 10%),we check with-This switch is gateway of our LAN.

View 6 Replies View Related

Cisco Switching/Routing :: Wireless APs Are Not Coming Up Of New Catalyst 4510R-E PoE

Sep 10, 2012

We have recently purchased Catalyst 4510R-E with two PoE line cards. When we connected Cisco Wireless APs to Cat4510 PoE ports it did not come up. These WAPs are working fine on other Cisco switch with PoE ports so there is no issue with WAP. We have received two CAT4510 and on both two slots are populated with PoE line cards and on both switches WAPs are not coming up. PC/desktops are working fine on these ports.Is there any configuration required on Cat4510 to enable PoE feature.

View 15 Replies View Related

Cisco Switching/Routing :: 4510R-E With Dual SUP V / 10GE IOS Upgradation

Sep 23, 2012

We have CORE switch model : Cisco WS-C4510R-E with dual SUP 5 - 2 10GE. [code] Now We want to upgrade this IOS to the upgraded version.

View 3 Replies View Related

Cisco Switching/Routing :: How Much Power Required From Utility Or UPS For 4510R Switch

Nov 13, 2011

We have one switch 4510R which could have total 300 cisco GE color phone connected. That means 300x15.4=4620W. Considering the 89% effiency for the PoE line cards, that means each line card needs 5191W input power from chasis power supply. Based on the 6000W power supply specs, only up to 4800W is allocated for PoE purpose. But we need 5191W from power supply which redundant mode can't offer. We don't want to go with combined mode. So should we add external power shelf to add more power?Another question will be how much power we need from utility or UPS. For example, the efficency of cisco power supply is 75% and we use two 6000W power supplies in redudant mode. Then we need 8000W. The voltage is 220V. Then the AMP we need is 36.4A from UPS or utility power.

View 2 Replies View Related

Cisco Switching/Routing :: High CPU Utilization On 4510R Switch With Dual SUP V -10G

Feb 14, 2012

We have a problem of igh CPU Utilization in Cisco 4510R-with dual SUP V-10G modules.
 
Cisco 4510R switch is the CORE switch and have 30 no's of VLans. It was running PVST/PVST+ previously. But Now we have migrated to MST. But after upgradation the CPU utilization reached alomst 98%.

View 2 Replies View Related

Cisco Switching/Routing :: 4510R+E - Dual Sup 7e Software / ROMmon Upgrade?

Jun 1, 2011

We have some 4510R+E with dual sup 7e that have experienced problems recently.  One of the sup 7e's crashed with a "critical software exception":
 
#show verCisco IOS Software, IOS-XE Software, Catalyst 4500 L3 Switch Software (cat4500e-UNIVERSALK9-M), Version 03.01.01.SG RELEASE SOFTWARE (fc1)
<snip>
ROM: 15.0(1r)SG1
<snip> Last reload reason: Critical software exception, check bootflash:crashinfo_iosd
  
So I thought I'd upgrade to IOS-XE 3.2.0SG to hopefully resolve the issue.  I was reading the software release notes and it says:
 
If you are upgrading to 3.2.0SG, you must upgrade your ROMMON to 15.0(1r)SG2.If they have dual supervisors, first upgrade your software to 3.2.0SG, then upgrade your ROMMON to15.0(1r)SG2 to avoid the resets uplinks issue (CSCtj54375). 

And from the ROMMON release notes it says:
 
Download the cat4500+e-promupgrade-150_1r_SG2 program from Cisco.com, and place it on a TFTPserver in a directory that is accessible from the switch that is upgraded.The cat4500+e-promupgrade-150_1r_SG2 program is available on Cisco.com at the same location from which Catalyst 4500 system images are downloaded. 
 
So I have several questions:
 
The only promupgrade file I can find is cat4500-e-ios-promupgrade-150-1r-SG2  (which doesn't appear to be the same as cat4500+e-promupgrade-150_1r_SG2 ). Where the correct file is?Since I have dual supervisors, it says I should upgrade the software, then the ROMMON.  If I can do that (run the new software with the old ROMMON) why am I bothering to upgrade the ROMMON in the first place? (update, ok, I see the new ROMMON gives me enhanced crash info and will allow future upgrades without bringing down both supervisors at the same time).When these were ordered/installed, the licenses were all mixed up (I wasn't involved with that   ).  So the MDFs have dual sup 7e with ipbase and the IDFs have single sup 7e with enterprise services. Obviously, we want the enterprise services in the MDF so we can run OSPF and the ipbase in the IDF.  But, OSPF seems to be running just fine in the MDF on ipbase.  Are the licenses not enforced on these platforms?  The release notes for 3.2.0 say ipbase doesn't support OSPF.  So if I upgrade the MDF switches, will OSPF suddenly stop working? 
 
The IP Base image does not support enhanced routing features such as Nonstop Forwarding (NSF) , BGP, Enhanced Interior Gateway Routing Protocol (EIGRP), Open Shortest Path First (OSPF), Intermediate System-to-Intermediate System (IS-IS), Virtual Routing Forwarding (VRF-lite) and policy-based routing (PBR).

View 1 Replies View Related

Cisco Switching/Routing :: 4510R L3 / Make Active Sup6 In Slot 6 Which Is Currently Standby Sup In Chassis

Mar 25, 2013

I have cisco 4510R L3 switch with installed 2 Sup on slot 5 and 6. the current active Sup is in Slot5 i want to make active Sup6 in slot 6 which is currently standby sup in chassis. Is there any way to make standby Sup to ACTIVE without reloading any of the Supervisor. however there is two way as per my understanding -

1. we can reload the active Sup so that standby Sup will take charge. - (redundancy reload shelf)

2. we can focefully switchover the state of Sup's by (redundancy forcefully swithover) but in above both cases reload will be performed by one of the supervisor. which i don't want.

View 2 Replies View Related

Cisco Switching/Routing :: Radius Server Command Missing From Global Configuration Mode 4510R

Feb 22, 2013

I came across an interesting issue and thought I would see if anyone else has encountered it before contacting TAC.I have two Cisco Catalyst WS-4510R-E switches with a single Supervisor V module in each chassis.  Both Sup cards are now running 12.2(54) SG1; ipbasek9 firmware; yes, I plan to move both switches to 15 code but that's another story.  Anyways, prior to the upgrade the one switch was running 12.2 (33) code; I suspect the code was never upgraded; running ipbase non - K9 code.  The other switch was running 12.2(44) with K9 prior to upgrade to 12.2(54). 

View 2 Replies View Related

Cisco Switching/Routing :: Radius Server Command Missing From Global Configuration Mode 4510R-E

Apr 23, 2012

I have two Cisco Catalyst WS-4510R-E switches with a single Supervisor V module in each chassis.  Both Sup cards are now running 12.2(54) SG1; ipbasek9 firmware; yes, I plan to move both switches to 15 code but that's another story.  Anyways, prior to the upgrade the one switch was running 12.2 (33) code; I suspect the code was never upgraded; running ipbase non - K9 code.  The other switch was running 12.2(44) with K9 prior to upgrade to 12.2(54).  With the background set, one switch reports the following:SwitchA (config)#r?radius-server  redundancy regexp represourc rmon route-map router.

View 4 Replies View Related

Cisco Switching/Routing :: 4510R-E / Unable To Create A Port-channel And Apply Auto-qos For VOIP

Sep 15, 2011

I have a 4510R-E chassis with SUP7-E running IOS XE version 3.01.01.SG.  I am unable to create a port-channel and apply auto-qos for VOIP.If I configure auto-qos on the physical interfaces, I get this message when I try adding them to the port channel:
 
"The attached policymap is not suitable for member either due to non-queuing actions or due to type of classmap filters."
 
Auto-qos is not an available command in the port-channel interface configuration, but if I try adding the service policies that were created by auto-qos to the port channel manually, it lets me apply the input policy but on the output policy I get this message:
 
"A service-policy with queuing actions can be attached in output direction only on physical ports."
 
With the input policy applied to the port-channel interface, I tried addign the output policy to the  physical ports and I got this message:
 
"A service-policy with non-queuing actions should be attached to the port-channel associated with this physical port."
 
Is there a way to get the auot-qos policies applied to the port-channel properly?

View 3 Replies View Related

Cabling / Cards :: How To Add New Phone Line

Jul 14, 2011

I want to add a new phone line to a small office in a hotel. They have avaya phone system and they are currently using 6 or 7 phone lines. From the avaya wires are run to the 66 block and from there to the outlets. So i think i can connect a cable from the avaya to the 66 block and it automaticaly give an extension number, but how do i add a phone line number to that connection?

View 5 Replies View Related







Copyrights 2005-15 www.BigResource.com, All rights reserved