Cisco WAN :: Catalyst 6500 - Lawful Interception Sip-401 And Sip-200
Feb 21, 2011
Does SIP-401 module for 12000 series router supports LI IOS software, or that function can be activated only with sip-600. Can I run Lawfull Interception with sip-401 module on 12406 router ??
and can SIP-200 module for Catalyst 6500 run lawfull interception ios and be used for that purpose ???
View 1 Replies
ADVERTISEMENT
Jun 4, 2013
Are there any best practices for preventative maintenance on Catalyst Chassis switches. Looking to build a PMI schedule for a customer. Or is there evidence not to perform it at all. Things like re-seating line cards, cleaning fan exhausts, etc.
View 1 Replies
View Related
Feb 1, 2012
I have to config Lawful Intercept on 7600, IOS version 12.2(33)SRC6. Every step have be taken by "Cisco 7600 Lawful Intercept Configuration Guide".Such as: [code] So, config failed? or these objests should be created? or something?
View 2 Replies
View Related
Oct 29, 2012
I have 2x6500s series catalyst core switch. i configurated vss. all them are working normal. but i have one problem. some of my servers link is down sometimes. I configurated server links as etherchannel.at etherchannel not both of links down only one link down.this modules i used to connect servers to core switch. modules 3 and 7 slot.
View 7 Replies
View Related
May 4, 2011
Two days ago, a brilliant guy inserted a different ios in a Cisco Catalyst 6500 and erased the original ios. I have twice downloaded the original ios by xmodem (too much time!) and both of them, when I reload the 6500, it doesn't work: I have the following message:
loadprog: bad file magic number: 0x0 boot:cannot load "bootdisk:s72033-ipservicesk9_wan-mz.122-18.SXF11.bin"
Second time, when the ios uploaded, I checked the sup-bootdisk: and the flashboot: and both have the wrong ios listed, but it wasn't there: I've tried to delete it and squeeze it, but had a message saying "can't delete because the ios is not there" or something like this. I finished formatting both (flashboot: and sup-bootdisk:), tftp the ios, double-checked the bootloader, compared with other identical 6500 and reloaded again, just to find the same message I've written before.
Supervisor 720 PFC3B. Slots for disk0 and disk1 are broken or I can't read them from the rommon.
View 10 Replies
View Related
Jun 21, 2012
We are facing an issue with the NAM3.Version: 5.1(2-patch4)
we can not login using the GUI. when we try to login we are getting the following warning:
Initializing database. Please wait until initialization process finishes.(see attachment)
we have rebooted the NAM3 module but the issue is not solved. the NAM3 module is running on 6500 Series Switch.(Cisco Catalyst 6500 Series Network Analysis Module (NAM-3)
View 5 Replies
View Related
Mar 16, 2012
i have a question regarding egress queuing on cat6500 modules. e.g. WS-X 6704 has 1p7q4t is egress-modell. my goal is to limit the priority queue to 15% of the available bandwidth. i can put weights on the wrr-queues and limit their ressources: "wrr-queue bandwidth 50 20 15 0 0 0 0." but this isn´t possible for the priority-queue. only available command is "priority-queue queue-limit 15" but this only restricts the buffer to 15%.
at the end of the day i want to prevent that the wrr-queues don´t have remaining bandwidth when the priority-queue is saturated.
is there an easy way to restrict the bandwidth of the priority queue or do i have to implement additionally some kind of policing?
View 5 Replies
View Related
Nov 28, 2012
I set up Catalyst6500 Quad-SUP VSS system.I have a problem with slow BGP convergence(80sec) on VSS switchover.Each chassis has a bgp peer and "bgp graceful-restart" is disabled.I investigated BGP behavior with "debug ip bgp events" and "debug ip bgp update".I found that BGP process waited a peer to reply until timeout and after the timeout BGP table was calculated.I guess this timer makes the convergence slow.How can I adjust this timer value ?
View 7 Replies
View Related
Oct 5, 2011
Side Catalyst 6509 : cata6#sho running-config interface gigabitEthernet 8/15 Building configuration...
Current configuration : 224 bytes
!
interface GigabitEthernet8/15
switchport
[Code].....
View 6 Replies
View Related
Apr 26, 2012
Any step-by-step configuration guide of how to enable DAI on Cisco Catalyst 6500 Series Switches.
View 1 Replies
View Related
Mar 7, 2013
I was asked to mount ACESMs on each of the CAT6K switches of a VSS cluster (one ACESM on each individual switch).On a non-VSS environment, the "svclc module <slot> vlan-group <group>" command is used to bind the VLAN group to the module on a certain slot. But now I am facing a VSS scenario, I will need to combine switch and slot in order to reference each of the individual modules...
How do I "index" each of the ACESMs in a VSS cluster? ¿Is there an extension of the aforementioned command to be able to combine switch and slot information?
View 1 Replies
View Related
Dec 12, 2011
What is used DDR memory on DFC on linecards for Cisco 7600 or Catalyst6500? I thought that DFC has copy of TCAMs from PFC. That PFC only has TCAMs, and it doesn't have DRAM on itself?
I've been said that if I have full BGP table in memory on supervisor on 6500 (that should be DRAM on RP on MSFC) that I also need 1GB additional memory on DFC on linecards? Is this true? But that should implied that DFC also has copy from MSFC not only from PFC, is this correct?
View 5 Replies
View Related
Apr 30, 2013
I need to configure QoS (voice and video) for Catalyst 6500 series switches with Supervisor 2T modules and DFC4 linecards.
Is this radically different from what we do int he Sup32 and 720s? I was looking at some templates online, such as
[URL]
But I don't see anything for the new Supervisor 2T?
View 3 Replies
View Related
Mar 19, 2013
document which explians normal booting sequence in a 6500 Switch running IOS. What I am looking for is in which order the image is loaded in SUP, RP, SP etc
View 1 Replies
View Related
Dec 20, 2011
I got problem with wake on LAN software.. The software unable to ON all pc's remotely if sitting under different vlan. Everything is ok if using the same vlan. Below are the network diagram & switch configuration.
Layer 3 switch Intervlan routing configuration
ip forward-protocol udp 7
!
interface Vlan4
description vlan Client-WOL
ip address 172.22.51.253 255.255.254.0
ip access-group Deny_HTTP_Vlan1 in
ip helper-address 172.20.1.246
[code].....
After configured all the switches with the above setting, the software still cannot wake all the pc's using LAN. Base on sniffing, i can't find UDP port usage by the software. Attached here with print screen from wireshark.
View 7 Replies
View Related
Sep 21, 2012
1. We now have SupA & SupB in the chassis, due to some mistake we have same IOS version but different feature set on them, although we configured redundancy mode sso, in the "show redundancy" we see Operating Redundancy Mode = rpr due to Software mismat, we now need to fix them as same feature set image, if I use "copy sup-bootdisk0:/xxxx slavesup-bootdisk0:/xxx", then write memory, does this cause any service/network interuption?
Available system uptime = 1 year, 1 week, 4 days, 9 hours, 21 minutes
Switchovers system experienced = 2
Standby failures = 0
Last switchover reason = active unit removed
[code]....
2. We did a failover test with this status, found that if we triggered supervisor failover, all modules will reload thus the services if interupped. How about after we make the Operating Redundancy Mode as sso, will this behaviour shows again? Or a stateful failover will happens, then modules no need reload?
3. We are using OSPF as our L3 routing protocol, after reference to the configuration, nsf should be enabled, we want to ask in the OSPF-domain nsf should be configured in all OSPF-enabled router or only 6500 which have dual-sup?
4. We also found that the interfaces(3 * Gig & 2 * TenG) in Standby supervisor cannot be use even enabled & configured, is it because we are running rpr mode now or will be the same even change to sso? Before customer have some older supervisor in 6500 non-e chassis, and they can use the standby supervisor interfaces as traffic forwarding, they use rpr-plus mode before, how about in sso mode?
View 6 Replies
View Related
May 5, 2013
"How to display the EOBC error counters in the Catalyst 6500 series switches and a definition of the EOBC interface" document here on support forum stays that The Ethernet Out of Band Channel (EOBC) is a half duplex channel that services many functions, which include the Simple Network Management Protocol (SNMP) and the packets that are destined for the switch.
Previously i were thinking that EoBC used only for SCP and SLP protocol. In addition i found other article (but not on cisco site, heh) where stays that The Results bus is a control plane, while the C (EoBC) bus is more of an "admin plane", thus you will never see data packets (such as CDP, SNMP, etc.) going over the R or C bus.
So there is a big contradiction between those two statements. How to prove one of those and if first one right, what meaned under the packets that are destined for the switch in it? SCP and SLP or other traffic as well?
View 3 Replies
View Related
Apr 22, 2013
I am migrating services from SUP720-3B to VS-SUP2T-10G= and moving to a VSS configuration between a pair of Cat6506 distribution layer switches. I need to enable QoS on these switches, primarily to trust dscp and also to prioritise voice traffic. The autoqos feature works for some ports but does not work on port-channel interfaces and port-channel member interfaces. How can I apply the qos settings for these interfaces in line with what auto qos would normally provide. My line cards are as follows:
Civic_6506VSS#sho mod
Mod Ports Card Type Model Serial No.
--- ----- -------------------------------------- ------------------ -----------
1 4 CEF720 4 port 10-Gigabit Ethernet WS-X6704-10GE
[Code].....
View 1 Replies
View Related
Apr 22, 2012
we have applied route-map on vlan interface in the form:
ip access-list extended TEST
permit ip 172.16.1.128 0.0.0.127 172.16.0.0 0.0.255.255
route-map TEST permit 10
match ip address TEST
set ip next-hop 172.16.111.1
interface Vlan11
ip policy route-map TEST
The problem is in the traffic matching by the rule - there is matches not only for 172.16.0.0/16 prefixes but for the whole traffic in that VLAN.
View 1 Replies
View Related
Jan 23, 2011
The diagram below is the configuration we are looking to deploy, that way because we do not have VSS on the 6500 switches so we can not create only one Etherchannel to the 6500s.Our blades inserted on the UCS chassis have INTEL dual port cards, so they do not support full failover.
Questions I have are.
- Is this my best deployment choice?
- vPC highly depend on the management interface on the Nexus 5000 for the keep alive peer monitoring, so what is going to happen if the vPC brakes due to:
- one of the 6500 goes down
- STP?
- What is going to happend with the Etherchannels on the remaining 6500?
- the Management interface goes down for any other reason
- which one is going to be the primary NEXUS?
Below is the list of devices involved and the configuration for the Nexus 5000 and 65000.
Devices
· 2 Cisco Catalyst with two WS-SUP720-3B each (no VSS)
· 2 Cisco Nexus 5010
· 2 Cisco UCS 6120xp
· 2 UCS Chassis
- 4 Cisco B200-M1 blades (2 each chassis)
- Dual 10Gb Intel card (1 per blade)
vPC Configuration on Nexus 5000
TACSWN01
TACSWN02
feature vpc
vpc domain 5
reload restore
reload restore delay 300
[code]...
View 22 Replies
View Related
Oct 11, 2011
I want to know the difference between the software that is Modular and the one that is not. What are the pros and cons ?
CAT6000-SUP32 IOS ADVANCED IP SERVICES SSH or CAT6000-SUP32 IOS ADVANCED IP SERVICES SSH (MODULAR)
View 1 Replies
View Related
Jun 5, 2012
I tried to configure netflow without success.
Setup is the following.
Cisco Catalyst 6509 with Sup720-10GE IOS 12.2(33)SHX7. There are around 30 L3 vlans configured on the switch. I'm only interested for the traffic on one L3 vlan which is the connection to wan cloud.
I wanna see only the traffic that goes to and come from the wan. On other Catalyst where I have routed interfaces i successfully configured netflow. I read a lot in the forums and documentations but i didn't find the right one.
View 1 Replies
View Related
Dec 10, 2012
Catalyst 4500 or 6500 VSS Capabilities?
View 6 Replies
View Related
Aug 10, 2012
Is there functionality difference in Supervisor Engine 2 and Supervisor Engine 2T for Catalyst 6500 ?
View 3 Replies
View Related
Dec 15, 2011
Its possible FTTx on a 6500 ?
View 2 Replies
View Related
Jul 16, 2012
one of the most widely deployed switches in the world. The "Swiss Army knife of network", can do routing, switching, security, wireless and almost everything that you would want your core switch to do. Remember to use the rating system to let Akshay know if you have received an adequate response.
Akshay might not be able to answer each question due to the volume expected during this event. Remember that you can continue the conversation on the Network Infrastructure sub-community LAN, Switching and Routing discussion forum shortly after the event. This event lasts through July 27, 2012. Visit this forum often to view responses to your questions and the questions of other community members.
View 22 Replies
View Related
Jul 21, 2012
how to safely remove the WiSM2 from the Catalyst 6500 series switch? According to the documentation "Catalyst 6500 Series Wireless Services Module 2 Installation and Verification Note":
To remove the WiSM2, perform these steps:
Step1 Shut down the module by one of these methods: In privileged mode from the router prompt, enter the hw-mod module mod shutdown command. NoteIf you enter this command to shut down the module, you must enter the following commands in global configuration mode to restart (power down, and then power up) the module: Router# no power enable module modRouter# power enable module mod If the module does not respond to any commands, press the SHUTDOWN button located on the front panel of the module.
Step2 Verify that the WiSM2 shuts down. Do not remove the module from the switch until the POWER LEDis off.
But, in the case of Step1 (1st methods) I do not see a option "shutdown" in the command "hw-mod module 3"...
All I prompted to enter is: c6500#hw-module module 3 ?
boot Specify boot options for the module through Power Management Bus control register
reset Reset specified component
simulate Simulate options for the module Is it hidden options?
IOS version of c6500 is 12.2(33)SXJ1
In the case of Step2 (2nd methods) there is not any button on the front panel of the module?
And yet, it is better to remove the module configuration manually or use the command module clear-config prior to removing the module?
View 14 Replies
View Related
Apr 12, 2012
Is it possible to modify conf with snmp on ace module like others 6500 catalyst ?Is ace answer to snmpset cmds ?
View 1 Replies
View Related
Nov 15, 2011
how to identify which modules are supported by cisco catalyst 6500. is there any OID which can give us the information
View 2 Replies
View Related
Jun 29, 2012
I want to know what is this process used for on a catalyst 6500 ? we have got following message in the crash file, probably due to CSCsv77354
Jun 30 16:06:47.099 UAE: %SYS-6-STACKLOW: Stack for process ACE HAPI running low, 0/6000
View 3 Replies
View Related
Mar 24, 2013
cisco WS-C6509-E Core switch with IOS "s72033-ipservicesk9_wan-mz.122-18.SXF11"
i have 2 question
Q.1 i want to upgrade this switch what is the latest IOS ver. supported by this module ?
Q.2 i need to enable http server on this switch when i run this comman it's accsebt but i cant get http work
View 1 Replies
View Related
Mar 26, 2012
Is it possible to issue eigrp leaking routes on catalyst 6500 running IOS 12.2-33SXI9 on gigabitethernet interfaces? or is there another way to acomplish this?
View 10 Replies
View Related
May 23, 2012
I has a issue about etherchannel beetwen 02 Catalyst 6500 switch, i need your comment about it. if you had any similar experience:
1.- On Catalyst Switch 6500-1: I configured interface port-channel 4 and associated it to G6/29 and G6/30 interface Port-channel4description IUU1_Gn1_HLIMSGSN01_Port_channel_6_29_6_30switchportswitchport trunk encapsulation dot1qswitchport trunk allowed vlan 406,408switchport mode trunkswitchport nonegotiatelogging event link-statusload-interval 30mls qos vlan-basedmls qos trust dscp!
2.- On Catalyst Switch 6500-2: I configured interface port-channel 4 and associated it to G6/29 and G6/30
interface Port-channel4
description IUU2_Gn2_HLIMSGSN01_Port_channel_6_29_6_30
switchport
switchport trunk encapsulation dot1q
switchport trunk allowed vlan 407,409
[code]....
and i see output "show interface Po4A" up up on switch-1, "show interface Po4B" up up on switch-2
5.- In the show running-config not appear configured Po4A and Po4B. it only show on outputs
6.- Po4A and Po4 was not configured on neither switches, my question is why appear Po4A and Po4B on switch-1 and switch-2 respectively? and why Po4 appear in down down.
7.- I solved this issue by shutdown and not shutdown to the interfaces on both routers, currently all is OK.
View 4 Replies
View Related