Cisco WAN :: Ios 12.4 Power Inline Time Range?

Feb 4, 2013

i have a ip-cam that is connect with power inline on my cisco router, i want to scheduler a reboot daily, of this ip-cam is there a posibility to use a daily time (time-range) to shutdown the interface and back up, or shutdown de inline power on this interface and back up ? i have ios version 12.4

View 4 Replies


ADVERTISEMENT

Cisco Switching/Routing :: WS-C3560-48PS-S Show Power Inline But No Power Available

Apr 14, 2013

We have two switches of the same model (WS-C3560-48PS-S) that are not providing PoE. I'm trying to remotely determine what the cause of the issue is.
 
Here is some output.
 
Hostname#show power inlineAvailable:0.0(w)  Used:0.0(w)  Remaining:0.0(w)
Interface Admin  Oper       Power   Device              Class Max                            (Watts)--------- ------ ---------- ------- ------------------- ----- ----Fa0/1     auto   off        0.0     n/a                 n/a   15.4Fa0/2     auto   off        0.0     n/a                 n/a   15.4Fa0/3     auto   off        0.0     n/a                 n/a   15.4Fa0/4     auto   off        0.0     n/a                 n/a   15.4Fa0/5     auto   off        0.0     n/a                 n/a   15.4Fa0/6     auto   off        0.0     n/a                 n/a   15.4Fa0/7     auto   off        0.0     n/a                 n/a   15.4Fa0/8     auto   off        0.0     n/a                 n/a   15.4Fa0/9     auto   off        0.0     n/a                 n/a   15.4Fa0/10    auto   off        0.0     n/a                 n/a   15.4(code)

View 1 Replies View Related

Cisco Switching/Routing :: No Inline Power On A 4506-E Port?

Oct 24, 2010

We have just purchased and installed a 4506-E chassis.  It contains a supervisor, two POE blades and 3 non-poe blades.  Version is 12.2(53)SG1.  Anyhoo, one of the ports isn't providing power to an IP phone.  We can plug the phone into any of the other POE ports and it works fine.  Is there a way to test an idividual port for POE problems?  What could the problem be?  The port works for normal data but will not provide power.

View 12 Replies View Related

Cisco Switches :: Not All SG300 Ports Supplying Inline Power?

Feb 26, 2012

Essentially, not all ports on our brand new SG300-28P switches provide Inline Power to our older 7900 series phones. I can connect the phone a couple ports down and it usually powers up, but not always. Often I can also connect an 802.3af device to one of the troublesome ports and it will received power, however I am noticing there are some ports that now refuse to supply PoE at all?
 
This is equipment that has been running perfectly fine for several years now, on C3524 PWR XL switches. I can also tell you that this is not isolated to one switch, but all 5 of our SG300 access switches. And, yes, the firmware has been updated to 1.1.2.0.

View 5 Replies View Related

Cisco Switching/Routing :: No Power Inline Commands On 1921?

Jan 27, 2013

I am running a 15.1 or so version of the IOS on a 1921 router. I have plugged in the external PoE injector into the router, and the PoE light on the front of the case is lit green. I have no options in the IOS to enable power on the EHWIC ports. I have most licenses enabled, including data and security.

View 6 Replies View Related

Cisco Switching/Routing :: Power Inline From PoE Blade (4548 / 4648)

May 3, 2010

I have a LAP-1142 connected to one of our PoE blade in our 4506 switch, it used to work fine with the following power consumption:
 
Interface Admin  Oper            Power(Watts)     Device              Class                            From PS    To Device                    --------- ------ ---------- ---------- ---------- ------------------- -----
Gi4/3     auto   on         21.5       20.0       AIR-AP1252AG-A-K9   3
 
However, we had power issue on Apr 28, so it failed and we saw from the log below:
 
Apr 28 13:57:38.990: %C4K_ETHPORTMAN-3-INLINEPOWEROVERDRAWN: Inline powered device connected on port Gi4/3 exceeded its hardware protection threshold.Apr 28 13:57:39.694: %PM-4-ERR_DISABLE: inline-power error detected on Gi4/3, putting Gi4/3 in err-disable state After the power restored later, the other LAP connecting with the same blade restored without any problem, except this one:
 
Interface Admin  Oper            Power(Watts)     Device              Class                            From PS    To Device                    --------- ------ ---------- ---------- ---------- ------------------- -----
Gi4/3     auto   on         16.6       15.4       Ieee PD             3

View 13 Replies View Related

Cisco Switching/Routing :: PoE Error On 6500 / Inline Power Module

Feb 12, 2012

Cisco IP phones attached to a Moduke in one of my Cat6500 access Switches suddenly went down. Upon closer  inspection of the Switch Sys log, I observed the following Sys log error messages:   [Module 9 is experiencing the following error: Inline Power Module - PS Voltage bad. ]A sh Mod output indicates the PoE daughter card and Main Module are "ok" - see attached output. It appears issue is related to the the actual Power Supply module and not the blade module and installed PoE Daughter card. I am inclined to open a TAC case for a PS replacement, but wanted to see if this can be resolved without a hardware replacement. At this time all 48 IP phones attached to this module are out of Service.

View 2 Replies View Related

Cisco Switching/Routing :: 3560v2 / Ws-c3560v2-48ps-s (inline Power Failure)

Jul 22, 2012

I have a switch 3560v2 with an IOS 12.2(50) SE1.All the lights ON and console error message below:POST: inline power post failed for port 0 up to port 15.Then, the system hanged and all lights (indicator) ON.

View 5 Replies View Related

Cisco Firewall :: 1941 - URL Filter Time-Range?

Apr 3, 2011

Just wondering if it’s possible to add a time-range for certain url filter policies on a cisco 1941?

View 1 Replies View Related

How To Power Off A Router On Given Time

Aug 17, 2011

I'm just wondering here, is it by any chance possible to power off a home network router on a given time? You know, perhaps schedule the up- and down times, when it's on and when it's supposed to be off.

View 13 Replies View Related

Cisco WAN :: 2960 - Power Off After Periodic Time?

May 22, 2011

One of my client useing 2960 switch but now face a problen after periodic time power off automaticaly. sometime cooling fan only run. Power of after 10 min or 3/4 hours and after power off it can get any power again. after 10/15 hours when power on then its works again but some times. whats is the problem hardware or software.

View 4 Replies View Related

Router Resets Itself Every Time Power Goes Out?

Sep 7, 2012

I use an adsl router to make a wireless network in my room.I keep the network hidden and also keep a password. The problem is, the power goes out twice a day for a minuite, and my router automatically resets itself when the power comes back on. Because of this I have to keep going to the router settings, set up a password and hide the network twice a day.

View 1 Replies View Related

Cisco Firewall :: ASA 5510 - Time Range / Allow Single Port During Business Hours Only

Apr 1, 2012

I'm new to an ASA 5510 running 8.4(3) and am trying to figure out something regarding time ranges in ASDM. I simply want to allow a single port during business hours only (I'm not concerned about open sessions needing to be closed). So as an example I add a rule something like:
 
(RULE1 on the internal interface) SRC=INTERNAL DEST=ANY SERVICE=RDP ACTION=PERMIT with a time range set for weekdays 8:00-16:59. I did a test after 5pm on a weekday and was still allowed to do RDP to a server (from INTERNAL), and after using the packet trace tool saw it was still passing through due to a rule a couple lines down (rule 4) that allowed a port range that happened to include port 3389. So my question is if I specify an "allowed" time range and someone attempts access outside that time range, why doesn't it drop it right there? I guess I'm assuming that anything outside the "allowed" time range would be dropped but that doesn't seem to be the case. I'm also assuming the rule base is processed top to bottom.

View 2 Replies View Related

D-Link DIR-825 :: Using NTP Server But Time Not Correct After Power-cycle?

Nov 27, 2011

I have access controls setup on my DIR-825 which work fine until there is a power outage and my router comes back up.I am using Automatic Time Configuration and have the NTP server set to ntp1 [URL]When the router comes back up I checked to make sure the NTP server option is still enabled, and it is, however the current time is totally wrong.To fix this I had to go to the pull-down, select 'ntp1.dlink.com' and then save the settings. After this the time is correct again.This is as bad as not having the Automatic Time Configuration option at all, since I can't guarantee that the power won't go out. I do not have a UPS hooked up to back up the router, nor do I see why I should need one if the Automatic Time Configuration actually worked.know if there is a way of making the Automatic Time Configuration reliable so the time on my router is automatically corrected when the power comes back up?

View 3 Replies View Related

Cisco Wireless :: WLC 4400 / Reducing Power Transmission On Multiple LAP At One Time?

Apr 10, 2012

I'm trying to modify the power transmission control of multiple Lightweight Access Points (1131 AG E K9) at one single time on WLC 4400 or WCS.It is effectively possible to configure the power transmission per LAP and in global on WLC 4400 but i need to configure it per group of LAPs =i.e group X of 10 LAPs will have a power Threshold of X -dBm and group Y of 15 LAPs with Y -dBm.

View 3 Replies View Related

Cisco Wireless :: Normal Boot Time For Aironet 1130AG With Power Injector?

Jun 1, 2012

I have installed an Aironet 1130AG and utilized a power injector for the power source.  I have the settings configured correctly in IOS, but the AP takes about 7 minutes to come on (illuminate LED status lights) once the Ethernet cable is connected. Is this 7 minute power-on delay normal when using POE?  I am used to the instanteous "on" that usually comes with Cisco products being connected directly to the AC adapter. 

View 5 Replies View Related

Cisco Wireless :: WAP321 Time Resets To 1999 On Reboot / Power Loss

Jan 25, 2013

I have 3 WAP321, all set to uk time zone, all the settings restore apart  from the time, on reboot that defaults back to 1999 despite NTP server  listed, interestingly have to manually reset time to present before NTP  will update it.

View 1 Replies View Related

Cisco Wireless :: 4402 - Setting Update Time For Auto Tx Power Level Assignment

Dec 1, 2011

We have a WLC 4402 controlling 40+ LWAPs.  Is there a way to keep Tx power level assignment dynamic, but set the time of day it does it?  I'd like to minimize user impact.  (Firmware v. is 7.0.116.0)

View 2 Replies View Related

Cisco :: LMS 4.2 Device Inline Edit

Jul 15, 2012

In previous versions of LMS, I navigated to RME - Devices - Inline Edit to increase the snmp timeout.  I haven't been able to locate the same process in LMS 4.2. Where I can locate this feature?

View 1 Replies View Related

Cisco Application :: Installing 294 Inline At A Site

Apr 8, 2012

I have a new deployment I am working on.  I am unclear on the Inline setup. One location is configured as a trunk between the router and the switch, with voice and data traffic going through it. We will be installing a 294 inline at this site.What impact will it have on voice traffic?  We are using G0/0 for management, not the Inline interfaces. Is that any additional configuraiton needed to inline if done this way? I didn't get prompted for vlan ID, or anything like that during the setup as an accelerator.Are these setup with default optimizations out of the box, or is there additional programming needed once they are online?  I found where to build custom applications, but wonder if there is anything needed to be done once they are online for default traffic.

View 1 Replies View Related

Two Inline Routers But No Internet Access

Jul 17, 2011

I am having issues getting my (now former) routers to have internet access. They also kept seeming to become unresponsive when trying to change the settings and continual resets were necessary. 2 of them have now lost a battle with a sledgehammer and before I acquire a new one I want to know if my laptop is somehow infecting these routers, because 3 of them had similar symptoms before they met their fate with a 12 lb sledgehammer.This is in an apartment complex. Next to the cable modem, there is a Netgear router. This router has 4 outputs with ethernet cable going to 3 different apartments, one of them is mine which is in a separate building 200 hundred feet away. Rather than run an ethernet cable this distance, I made a reflective enclosure installed it under a carport and broadcast a signal to my apartment, and this worked great for 3 years. When the router next to the cable modem failed and was replaced, my personal router would no longer transmit the internet to my apartment.

View 11 Replies View Related

Cisco Application :: ACE 4710 Inline VS One-armed Based

Apr 3, 2012

I have 2 basic questions I am having doubts about it and would love to have some clarifications:
 
1) I configure in one ACE4710 (running 4.2.2) context a bridged interface and in another context the same interface, like here below : [code] Then I move to the Juniper context and I try to create an interface (either L-2 or L-3) but it doesn’t work: [code] So if I configure an interface as bridged in one Context, I cannot configure it in another context??
 
 2) If I want to migrate in context Microsoft from One-armed to inline (L-2 bridged), can I migrate one service at the time ( I.e. the config i showed above for context Microsoft, would it work also for one-armed based???)

View 1 Replies View Related

Cisco AAA/Identity/Nac :: 1.1.1 / Unable To Register ISE Inline Posture Node

Oct 19, 2012

i'm stuck at registering inline posture node to primary node. I doing fresh install both ISE appliance using version 1.1.1, patched all 3 available patach version after install. AD and DNS were perfectly configure, ping using hostname able to resolve Everything  set, so both PSN and iPEP generate CSR and ready to let CA server to  signed. But anyway this is the outcome i get Error message "Unable to  authenticate. please check server and CA certificate."

01. - What certificate template to be use primary node and inline posture node?  I  having problem the CA certsrv won't show computer template for inline  posture node. can i use web server template and on the extension include  client autthenticaiton andserver authentication on this case?
 
- What certficate template use for primay node CSR?
  
02. According to Cisco ISE user guide 1.1.1, it mentioned "Creating certificate trust list in Primary ISE Node"
 
So  first action is importing Root and CA certificate . my rootCA.cer  import to certification operation certifcate store, while CSR  generated then Bind CA certificate. question, should i check anything like "Tust for client authentication" checkbox or any other option to be check? How about Inline Posture node, should i export the CA certificate and import to primary node's certificate store?

View 3 Replies View Related

Cisco AAA/Identity/Nac :: ISE-3315 / Procedure To Join ISE Appliance Become Inline Posture Node

Oct 17, 2012

I would like to ask, given that i got 2 units of ISE-3315 appliance, one need to be primary node for admin-policy service-monitoring, another unit then become Inline posture node.For the preparation on line posture node, what shoud i do on it?
 
01. For the unit ready to become inline posture node, so I just boot it, install the OS from sractch (using version 1.1.1), then start the initialize setup etc, like Normal setup?
 
02. Before i regieter, what is the deployment nodes i should select for inline posture node unit? provided the admin-policy service-monitoring will become primary node, and registration for inline posture node will be next action.

View 10 Replies View Related

Cisco Switching/Routing :: 3750 - Power Stack Has Unbalanced Power Supplies

Jun 9, 2013

I am receiving the following error on 3750 stack switches. have already verified the power status and found ok.
 
IOS used: Cisco IOS Software, C3750E Software (C3750E-UNIVERSALK9-M), Version 12.2(55)SE3, RELEASE SOFTWARE (fc1)

211540: Jun 10 10:45:17.935 UTC: %PLATFORM_STACKPOWER-4-UNBALANCED_PS: Switch 4's power stack has unbalanced power supplies
211541: Jun 10 10:46:18.045 UTC: %PLATFORM_STACKPOWER-4-UNBALANCED_PS:

[Code]....

View 1 Replies View Related

Cisco Switching/Routing :: Stack-power 3750x / FRU Power Supply Is Not Responding

Sep 4, 2012

After stacking two 3750X switches, with four equal power-supply's, with StackWise and PowerStack , still got the next message every few hours %PLATFORM_ENV-1-FRU_PS_ACCESS: FRU Power Supply is not responding (gn4m-rt1p08-04-2)( note that the message revers to the second switch in the stack ) although the stackwise and powerstack on the switches is oke and are working correctly. !
 
Config  : Stack-power in power-sharing mode/strict With CLI on the switch : All the power supply's and stack-power details, prio look OK.
 
Only: LMS prime /inventory/cisco-view/configure/power supply status  result :  some power supply's are marked as disabled.with the command  > power supply 2 slot a off/on I manage to get the status back to "normal", but after a few hours some power supply's are again marked as "disabled".
 
Looks like SNMP en IOS difference from opinion.
 
Hardware
WS-C3750X-24S-S
C3KX-PWR-350WAC
 
Software
15.0(2)SE
C3750E-UNIVERSALK9-M

View 5 Replies View Related

Cisco Wireless :: 1252 - WCS Reports AP Draws Low Power - With Correct Power Injector

Jul 21, 2011

I keep getting alerts from our WCS stating that our 1252s are drawing low power. Now I am aware that they require enhanced PoE (up to 20W) but as we only have standard PoE in that building we purchased the 1252 series power injectors to go with them.
 
However, even with the correct power injectors the WCS still reports the draws low power error.
 
Is this a bug? Running WCS 7.0.172 at the moment.
 
Forgot to say we are using the PWR-INJ4 and the injector status is enabled and you see the injector MAC address when you drill in to the AP status.

View 9 Replies View Related

Cisco Switching/Routing :: 6500 - Power-Redundancy Mode Combined And Power Fail

Feb 28, 2011

I have a 6500 chassis with 2 power supplies. At the moment  I am using the default configuration:
 
power-redudancy mode redundant
 
The problem is that an inserted module is in "power deny" state due too insufficient power.
 
I know, that It's not a good idea to change into combined mode (loss of redundancy), but my customers requested this anyway.
 
So I will change to combined mode. So here's the 1 million dollar question: "Which modules will go into power deny, if one of my power supplies fails?"
 
The 6500 config guide states:
 
"Power supply is removed withredundancy disabled
• System log and syslog messages are generated.
• System power is decreased to the power capability of one supply.
• If there is not enough power for all previously powered-up modules, some modulesare powered down and marked as power-deny in the show power oper state field."
 
Well, do you know if there's any way to configure some kind of priority? E.g. I definetly don't want by 10Gig Module or WiSM module to be in power deny. Can i statically make sure, those module will be powered on for sure? Like: "power enable module slot_number" How is this calculated? Or is random?

View 3 Replies View Related

Cisco Switching/Routing :: 3750X Stand Alone Secondary Power Supply Act As Pool Of Power

Apr 4, 2012

In a stand alone 3750x switch configuration, can the secondary power supply only act as a redundant power supply (active/standby), or can it become a "pool" of power similar to power sharing mode for StackPower (somewhat active/active)?  I understand there is no stack involved here but I'm curious if this functionality is possible.

View 1 Replies View Related

Cisco Firewall :: ASA 5512-X - Automatic Power-on After Power Failure?

Dec 5, 2012

how can I enable an automatic power-on after a power failure on an ASA 5512-X?

View 5 Replies View Related

Cisco WAN :: 2621 / Time-Based Access Lists Using Time Ranges?

Jan 4, 2011

I have one 2621 router i want to creat time base access list so that one of my subnet user(10.128.194.0 255.255.255.128) use only internet between 11am to 2pm.

View 15 Replies View Related

Cisco Wireless :: WAP321 Lost Time - Cannot Sync With Time Server

Jul 8, 2012

I just bought a WAP321 Wireless AP. I wonder why it cannot sync with our time server automatically. Every time I reboot it, the system time become "Fri Dec 31 1999 12:00:00 UCT".  I have to do the sync manually by clicking on the "Save" button under the menu Administration > Time Setting.

View 5 Replies View Related

Dell :: How To Enable Automatic Power-on After Power Failure On ASA 5512-X

Mar 3, 2013

how can I enable an automatic power-on after a power failure on an ASA 5512-X?

View 12 Replies View Related







Copyrights 2005-15 www.BigResource.com, All rights reserved