Cisco Switching/Routing :: Upgrading Supervisor In Cat 4500?

Feb 20, 2012

I have a 4510R-E chassis which currently has a single supervisor 5 installed.
 
We are now looking at upgrading the supervisor to a Sup6. Now the question is this, can I install the Sup6 into the redundant cpu slot and then perform a failover to get the new switch working without any noticable downtime.
 
I'm not sure what having a Sup V and a Sup 6 in at the same time will do to the backplane.
 
Otherwise I have to take the switch down and then install the card and software manually.

View 2 Replies


ADVERTISEMENT

Cisco Switching/Routing :: Upgrading Catalyst 4500 Series Supervisor

Jan 8, 2012

Does a new Cisco Catalyst 4500 series supervisor 7L-E model WS-X45-SUP7L-E is backward compatible with a Cisco Catalyst 4500 series chassis model 4507R? I've checked on Cisco website for that Supervisor and it shows only new chassis models WS-C4507R+E and R-E, but what about old type of chassis? We need to upgrade that Supervisor as it's out of line, but we don't really want to buy a new chassis as well as it's going to be very pricy.

View 6 Replies View Related

Cisco Switching/Routing :: Cat 4500 Supervisor 7-E Is Rebooting

Apr 24, 2013

I'm having a trouble with a 4510R+E switch.  The WS-X45-SUP7-E supervisors are constantly rebooting, and we can see a 'critical software exception reload' reason. We have checked the logs
 
______ uptime is 5 weeks, 1 day, 19 hours, 3 minutes
Uptime for this control processor is 37 minutes
System returned to ROM by reload

[Code]....

What can we do to solve this incident?. Everything was working fine, and suddently the problem arose.

View 7 Replies View Related

Cisco Switching/Routing :: QoS Catalyst 4500 7E Supervisor

Apr 15, 2012

I am trying to understand the implicit limit to the priority queue. I know you can define an explicit policer but if you don't I can't find out what the rate limit really is.

View 5 Replies View Related

Cisco Switching/Routing :: Upgrading Supervisor Engine On 4006?

Nov 3, 2011

I have an older 4006 with a Supervisor II+.  We now need OSPF support, which the Sup II+ does not provide.  I have access to a Supervisor III (WS-X4014), which will provide OSPF support.  Question is, are there any gotchas to shutting down the switch, replacing Supervisor Engines and then powering up?  What about the flash card?  On my current system, it appears that I am only using bootflash: , which is where the IOS resides (see below).  Since my startup config is in nvram and my IOS is in bootflash, what's the purpose of the flash card in slot0: ?  and where does NVRAM and bootflash actually live on a 4006 ( on the Supervisor Engine?)
 
sh bootvar
BOOT variable = bootflash:cat4500-ipbase-mz.122-31.SGA11.bin,1;,1;
CONFIG_FILE variable does not exist
BOOTLDR variable does not exist

[Code].....

View 5 Replies View Related

Cisco Switching/Routing :: 4500 Standby Supervisor Not Detected?

Nov 25, 2011

I have issue with my 4510 switch which has got two supervisor engine in single switch.
 
I am trying find the root cause but not able to ....
 
Standy supervisor engine is not detecting ....
 
In show module and bootvar output also , there is error saying " Standby is not up "
 
show module ouput :
 
Switch-4510#show moduleChassis Type : WS-C4510RPower consumed by backplane : 40 WattsMod Ports Card Type Model Serial No.---+-----+--------------------------------------+------------------+-----------1 6 Sup V-10GE 10GE (X2),

[Code].....

View 11 Replies View Related

Cisco Switching/Routing :: 4500 Supervisor Engine Error

Mar 16, 2012

On an existing 4500 switch with a single sup 6-E, another sup 6-E is added. But the second sup6-E comes up as synchronised with active and in a few minutes time, reloads again. the software is 12.2(44) is the same on both sup engines. the redundancy sso output shows that slot6 is disabled.

View 1 Replies View Related

Cisco Switching/Routing :: 6509 Crash When Upgrading Supervisor Card

Nov 23, 2011

Problem I have encountered when upgrading a Cisco 6509 chassis with a new supervisor card from Sup2 to Sup 720b. The 6509 loads and then crashes completely, and when rebooted reloads into rommon.The same upgrade was performed on a similar switch with no apparent problems.
 
[code]....

View 4 Replies View Related

Cisco Switching/Routing :: Core 4500 Series Supervisor Engine?

Jun 19, 2012

Our company will go to buy a core switch 4503. What is the difference between the Catalyst 4500 E-Series Supervisor 7L-E and the Catalyst 4500 E-Series Supervisor 7-E?

View 1 Replies View Related

Cisco Switching/Routing :: 4500 Requirement For NSF / SSO Commands On Standby / Active Supervisor

Apr 22, 2012

I went through the configuration guide for 4500 series switches for NSF/SSO for failover between Sup's. I just wanted to know that that are we supposed to run the SSO command on both of the supervisors? Secondly, are we only supposed to run the nsf process under EIGRP on the secondary supervisor and routing peers and not on the primary supervisor?

View 2 Replies View Related

Cisco Switching/Routing :: Configuration Module Supervisor Switch Catalyst 4500

Jun 4, 2012

switch catalyst 4500 with ios cat4500e-universal.SPA.03.02.00.XO.150-2.XO.bin. I need to configure modules 3 and 4 of supervision, the problem is that I need the 4-port module 3 are active but only the first turn on both the module 3 and the first port on the module 4. [code]

View 1 Replies View Related

Cisco Switching/Routing :: 4500 - Redundant Supervisor 7-E - Use All Uplink Ports At Same Time

Dec 15, 2011

I know in the past on earlier models of the supervisors that you couldn't use all eight uplink ports(4 on each supervisor) simultaneously when you have two supervisors on the chassis.  Is this the same case for the 10Gb uplinks on the supervisor 7-E on the 4500 chassis?  I tried doing my research but couldn't find an answer.

View 3 Replies View Related

Cisco Switching/Routing :: Upgrading Memory For Redundant Supervisor Modules Nexus 7K18?

Mar 6, 2012

I have a doubt about upgrading Memory in Redundant Supervisor Modules Nexus 7K18, i read the Cisco Nexus 7000 Series Hardware Installation and Reference Guide, and the process for upgrading the memory in redundant supervisors do not says that i can have a lose of service, but it also says that both supervisor modules must have the same amount of memory for redundancy to work;If the switch has two supervisor modules, both must have the same amount of memory. If you upgrade the standby supervisor module to 8 GB of memory, you must then switch the active supervisor to standby and upgrade the new standby supervisor to 8 GB of memory.

View 1 Replies View Related

Cisco Switching/Routing :: Upgrading Catalyst 4500 Power Supplies?

Sep 19, 2012

If I'm upgrading dual redundant power supplies in a Catalyst 4507 from 1000W (data) to 1400W (data), can it be done without taking the switch through a power cycle? I'm guessing no as I read that the switch will not recognize a 1400W PSU in bay 2 if there is still an original 1000W PSU in bay 1.

View 2 Replies View Related

Cisco Switching/Routing :: Upgrading Software Image On Catalyst 4500?

Dec 31, 2012

I just received a new 4510R+E switch with CAT4500e SUP7e Universal Image cat4500e-universal.spa03.01.01.sg.150-1.x01.bin software imag with License Level ipbase. We specified in the order to receive CAT4500e Universal Crypto Image with License Level ipbase. I have since requested and received the latest CAT4500e Univeral Crypto Image cat4500e-universalk9-spa.03.04.00.sg.151-2.sg.bin. Is there anything other that just installing the new image that must be done to allow me to use the Crypto Image? Would this upgrade do anything to change my License Level ipbase?

View 1 Replies View Related

Cisco WAN :: 4500 Switches With Supervisor 6E-L

Jun 8, 2011

we got 2 Cisco 4005 Switches with IOS 12.x. t.Now we have two new Cisco 4500 Switches with Supervisor 6E-L.But i dont really understand the new syntax / configuration method of ios 15.

View 2 Replies View Related

Cisco WAN :: Catalyst 4500 E-Series Supervisor Engine 7L-E?

Aug 12, 2012

I have a strange issue with 4500 E chassis loaded with SUP 7L-E which always remains in ORANGE LED status, also the uplink ports interface is down and the line protocol is down  but when i execute the command sh int gig1/5 it show me the media type sfp but there is no red laser light seen in the sfp transiever,The below command is configured for the uplink gig port on the SUP engine.hw-module uplink select gigabitethernet?

View 10 Replies View Related

Cisco WAN :: 4500 Standby Supervisor Continuously Rebooting

Feb 26, 2012

We seem to be having an issue with one of our 4500's, our standby supervisor is continuously rebooting: [code]

I have replaced the supervisor board but the issue still persists. [Code] ......

View 6 Replies View Related

Cisco Switching/Routing :: 6509 / 4900 - Network Down Cause Switching Supervisor With Redundancy

Jan 11, 2012

we've had an issue with our network, we have 2 6509 connected with redundancy, which are connected with 2 x 4900 Switches, from which are connected to a ESX Chassis for visualization, the thing is that the ESX stopped working, and the 4900 switches, and the main core were suffering from overload, they hang on it very well, in order to stop the overload, one of the links to the ESX Chassis were disconnected from one of the 4900 switches. The CPU usage from the 4900 and the core(6509) went down below 40%, and then they started to migrate the virtual servers from the chassis to another 2 chassis that were added right after. They were actually working well, but suddenly the 6509 changed to the other supervisor after everything was OK. We were wondering what could have been the cause of this, maybe the virtual servers migrations, maybe the overload from the ESX ? We also had a few question, is there any need to reload the cores every few months as a planned task ? Because the cores have been up for more than 1 year. And also is there any kind of of tool to monitor the CPU status, or the status overall from the cores or the switches ?

View 3 Replies View Related

Cisco Switching/Routing :: Supervisor Engine 720 Errors

Apr 18, 2013

i have a standalone SUP720, no traffic is passing through it. only one port connected for remote telnet, its kind of backup device.today i checked its log, and there are some wiered message.is it a software bug or my SUP has gone bad? [code]

View 24 Replies View Related

Cisco Switching/Routing :: 6500 What Happens When A Supervisor Fails

Feb 3, 2010

We've been mocking up a test lab to test VSS on two 6500's.  Each 6500 has one sup720 and a 6708-10ge blade and we've established the two 10ge links between the two chassis; the first from the each chassis' sup and the second from each 6708.My question is, what happens when the supervisor fails on one of the chassis?

View 10 Replies View Related

Cisco Switching/Routing :: Supervisor 7-E / 7L-E Port Numbering

Jan 30, 2013

How the port numbering would be on Sup 7-E and Sup 7L-E? I mean, on Sup-6E and Sup-6LE, if I used a twin-gig converter, I used ports gi3/3,gi3/4,gi3/5 and Gi3/6 [If the sup is in 3rd Slot]. I know there are now 4 ports on the Sup 7 which can either be used as Gig ports or TenGig ports. So, how will the port numbering change ?

View 1 Replies View Related

Cisco Switching/Routing :: Supervisor 7L-E USB Port Is Not Working?

May 1, 2012

Nothing happens when we plug a USB Flash Drive into an SUP7L-E USB port.

View 4 Replies View Related

Cisco Switching/Routing :: VSS With 4 Supervisor Engine 2T-10GE

May 6, 2013

We have a scenario with 2 chassis, both with 2 supervisor Engine 2T, we try to make a configuration of VSS with the chassis and would link to know if is possible have 2 supervisor on chassis one and 2 supervisors on chassis 2 with VSS?
  
Router#sho switch virtual redundancy
My Switch Id = 1
Peer Switch Id = 2
Last switchover reason = active unit removed
Configured Redundancy Mode = sso
Operating Redundancy Mode = sso

[code]....
 
would like to use the second supervisors for obteind the local redundancy en chassis 1 and 2, this is possible?
 
the actually version on four supervisors is: s2t54-ipservicesk9-mz.SPA.150-1.SY3.bin

View 6 Replies View Related

Cisco Switching/Routing :: Catalyst 6500 / QoS For Supervisor 2T?

Apr 30, 2013

I need to configure QoS (voice and video) for Catalyst 6500 series switches with Supervisor 2T modules and DFC4 linecards.
 
Is this radically different from what we do int he Sup32 and 720s? I was looking at some templates online, such as
 
[URL]
 
But I don't see anything for the new Supervisor 2T?

View 3 Replies View Related

Cisco Switching/Routing :: Catalyst 4510R+E Supervisor 7-E SSO Not Available

Sep 22, 2011

I'm working on deploying a new 4510R+E for our organization.  This is my first experience with a modular switch.  I'm trying to enable SSO, however in the redundancy configuration mode, the sso command is not available.  Is SSO only available with certain software images / licensing levels? [code]

View 2 Replies View Related

Cisco Switching/Routing :: 6509 Supervisor IOS Upgrade

Oct 16, 2012

We are trying to upgrade the IOS on one of our 6509 switches. We have two 720 10GE supervisors running in SSO. Our procedure is reload the standby supervisor with the new IOS. We understand that you can only use one console connection when in RPR mode so we rely on the active supervisor giving us information that the standby unit is up and running.
 
The problem we have is that when we do a "show Module" on the switch the online diagnostics for the standby supervisor comes back us unknown. [code] We believe the active supervisor can see the standby supervisor because when we save the configuration we get a message saying that the config is sync'd with the standby router. We have a TAC case raised to investigate. We are upgrading from 12.2(33) SXI1 to 12.2(33) SXJ3

View 1 Replies View Related

Cisco Switching/Routing :: Catalyst Supervisor 32 NVRAM Location?

Feb 10, 2013

I have a Sup32 that I suspect has faulty NVRAM (e.g., I am unable to "wr mem" on the device - it states resource is busy but no other active connections exist). Prior to replacing the supervisor engine I'd like to take a crack at formatting NVRAM to see if it resolves the issue. This supervisor does not have a CF card installed, thus no Disk0:. Within the CLI, I am presented two options with the "format" command - bootflash: and sup-bootflash:. Bootflash: does not have any data on it, however, sup-bootflash: contains my IOS image. I believe that both of these locations are simply directories within NVRAM.

View 3 Replies View Related

Cisco Switching/Routing :: 6509 How To Configure VSS With Two Different Supervisor Engine

Oct 1, 2012

I have configured the VSS in two cisco 6509-E series with only one supervisor engine, but if i configured with two supervisor engine. it is going to common mode. One supervisor engine is 3c and 3cxl.

View 2 Replies View Related

Cisco Switching/Routing :: 6509 Adding A Redundant Supervisor?

Feb 10, 2012

I would like to add a redundant supervisor to my core 6509. Is this tricky to do? I know they have to be running the same IOS. I am worried if I put the new supervisor in it will write over the exsisting running config.

Catalyst 6000 supervisor 2 (Active)    WS-X6K-S2U-MSFC2
Policy Feature Card 2       WS-F6K-PFC2
Cat6k MSFC 2 daughterboard  WS-F6K-MSFC2

View 4 Replies View Related

Cisco Switching/Routing :: Catalyst 4006 Supervisor Engine Led Red

Nov 28, 2011

we got a problem with our cat4006 coreswitch. The led on the supervisorengine is red, and several errors are appearing in the message log. [code]

View 1 Replies View Related

Cisco Switching/Routing :: 6509 Supervisor Upgrade With FWSM?

Oct 8, 2012

We are planning to upgrade the IOS on our two 6509E supervisors in the next few weeks. We currently run IOS 12.2(33) SXI1 and are upgrading to 12.2(33) SXJ3. At the moment the two supervisors are in SSO mode and after reading many articles it says that when the images are different on the two supervisors they are in RPR mode. When you then reload the active supervisor it will reboot all the line cards.
 
1. Is above correct? Will my line card reload?

2. We also have a FWSM installed, When/If the line cards are rebooted does the FWSM also reboot?

View 1 Replies View Related

Cisco Switching/Routing :: Catalyst 6500 Dual-Supervisor 720-10G-3C?

Sep 21, 2012

1. We now have SupA & SupB in the chassis, due to some mistake we have same IOS version but different feature set on them, although we configured redundancy mode sso, in the "show redundancy" we see Operating Redundancy Mode = rpr due to Software mismat, we now need to fix them as same feature set image, if I use "copy sup-bootdisk0:/xxxx slavesup-bootdisk0:/xxx", then write memory, does this cause any service/network interuption?

Available system uptime = 1 year, 1 week, 4 days, 9 hours, 21 minutes
Switchovers system experienced = 2
Standby failures = 0
Last switchover reason = active unit removed

[code]....
 
2. We did a failover test with this status, found that if we triggered supervisor failover, all modules will reload thus the services if interupped. How about after we make the Operating Redundancy Mode as sso, will this behaviour shows again? Or a stateful failover will happens, then modules no need reload?
 
3. We are using OSPF as our L3 routing protocol, after reference to the configuration, nsf should be enabled, we want to ask in the OSPF-domain nsf should be configured in all OSPF-enabled router or only 6500 which have dual-sup?
 
4. We also found that the interfaces(3 * Gig & 2 * TenG) in Standby supervisor cannot be use even enabled & configured, is it because we are running rpr mode now or will be the same even change to sso? Before customer have some older supervisor in 6500 non-e chassis, and they can use the standby supervisor interfaces as traffic forwarding, they use rpr-plus mode before, how about in sso mode?

View 6 Replies View Related