Cisco Switches :: GBIC Compatible With SR224G?
Sep 4, 2011Can I use a Cisco GBIC (p/n 30-1301-02) in SR224G?
View 2 RepliesCan I use a Cisco GBIC (p/n 30-1301-02) in SR224G?
View 2 RepliesImagine I have from customer side SFP-10G-LR GBIC.Then circuit to be deployed is 1310nm, Metro. My question is, if I will receive 100Mbps from such circuit, is this 10 GBIC compatible with 100Mbps? 10GBASE-LR SFP+ transceiver module for SMF, 1310-nm wavelength, LC duplex connector )
View 3 Replies View RelatedThe switch has been set to Level 3 Routing. Port 27 has been in use as a Fiber Transceiver with no problems for several weeks. This week I tried connecting a second Fiber Transceiver to Port 28, and it would not work.
Swapped the physical GBIC modules in the ports, and the situation remained exactly the same: Port 27 works, Port 28 would not work.
Connected to the copper-part of the combo Port 28, it immediately connected and worked fine.
Connected an external Fiber Transceiver Box in place of the GBIC in Port 28, and it immediately connected and worked fine.
Swapped the new Fiber jumper (Port 28) with the existing Fiber jumper (Port 27), and the new connection came up immediately and worked fine. The existing connection would not work when connected to Port 28.
By "not working", I am not able to ping across the connection. The link light comes on and blinks. The transmit/receive statistics show as if data is processing on this switch, but on the other side of the Port 28 connection, the switch shows Transmit traffic, but no Recieve traffic.
I am interesting if GLC-SX-MM sfp modules are compatible with following switches: SG500X-48-K9-G5 and SG200-18.
View 7 Replies View RelatedLooking through the logs of our SF300 switches I am seeing errors for SNTP:
%SNTP-D-NTPBADVER: NTP server version not compatible
We have two NTP servers listed, both are MS Windows 2008 R2 domain controllers. The actual time on the switches seems to be correct but we are still receiving these errors?
Are 300 Series switches compatible with pre-standard PoE detection in old Cisco phones? They don't seem to be (a 7902G won't power on when connected to an SF302-08MP with firmware version 1.1). Is any special configuration needed on the switch to enable this detection?
View 2 Replies View RelatedI need to replace an older 3560 with a new 2960-S and am wondering if the SX SFPs I already have will be compatible with the 2960-S. [code] I cannot find any way to get the part numbers of the SFPs.
View 7 Replies View RelatedI am going to connect two Catalyst 2948G switches, and I want to know what the best GBIC is to use to do so. A link to a cable I could order would be great, or a brand and model number.
View 3 Replies View RelatedI have an interesting problem. I have a 6509 that I'm trying to swap the GBIC on. The switch is already using a GLC-SX-MM GBIC and it is up/up and passing traffic, but we are getting some errors and suspect it may be faulty.
I want to replace the GBIC with one of the identical model - a GLC-SX-MM. It was brand new, never been opened. When the new GBIC is plugged in the link light on the switch goes completely off (not amber) and the port goes into a down/down (not connect) state. There are no messages in the logs at all. It's like it doesn't even see it. If you plug the old GBIC back in then the link comes back up. I tried a different port with the same results.Thinking that the new GBIC may be faulty (even though it was brand new) I tried a second GLX-SX-MM, also new. That one does the same thing.
At that point I thought there might be a problem with that switch, so I tried the GBICs on the other 6509 in that pair. The other 6509 is running the same hardware and software. The GBICs will not work there either. If you move the old, suspected faulty GBIC from 6509-2 to 6509-1 then that it works.
The solution would seem to be that I have two faulty GBICs, but I'm having trouble persuading myself that I have two new ones, straight out of the package, that are both bad. Are there any other things to check on the switch? Here's the pertinent information:
switch#show ver
Cisco IOS Software, s72033_rp Software (s72033_rp-ADVIPSERVICESK9_WAN-M), Version 12.2(33)SXI3, RELEASE SOFTWARE (fc2)
<snip>
cisco WS-C6509-E (R7000) processor (revision 1.3) with 458720K/65536K bytes of memory.
Processor board ID SMG1109N3BK
SR71000 CPU at 600Mhz, Implementation 0x504, Rev 1.2, 512KB L2 Cache
[code]...
I have 3 switches
Catalyst 2960
Catalyst 3750
Hp procurve 1410 24g
I want to link them using fiber as they are almost 50 meters apart. What connectors should I use and what fiber optic cable can be connected to those connectors.I have found these connectors and cables on internet will these work
GBM-7000-S85 - 1000Base-SX, multi-mode, 550m, 850nm GBIC transceiver
SC to SC Multimode Duplex High Speed Fiber Optic Ethernet Patch Cable 62.5/125
I've inherited a network. It looks to have been setup as 10/100 originally, using Netgear FSM726S switches with fibre connecting the switches. The fibre to copper conversion is mainly achieved with 10/100 media convertors rather than GBICs - not sure why - though there are some GBICs in use. Some of the "key" switches have been upgraded to Cisco Catalyst 2960G switches, but nothing else has been touched, so most of the network still runs at 100MB.
View 1 Replies View RelatedIm trying to determine the serial number of Gbics already installed and running on a Catalyst 2950 switch. Is there a specific command to do so? There is a command on Catalyst 4506 that gives all info regarding the Gbic ("show idprom interface gi 1/1") Is there something equivalent for 2950?
View 4 Replies View Relatedis there a command that gives me the model and serial number of the GBIC modules inside the modules of the Cisco 6500 (IOS)?
View 7 Replies View Relatedactually i have problems with the connection between a Cisco 3750 and P750 server, the Cisco Gbic is X2-10G-SR and the card of the server is 10 Gigabit Ethernet-SR PCI Express Adapter, both uses 850 nm wavelength but i cant see link between the two cards, the physical connection is with a fiber cable with a conector SC in the server and LC (cable adapter) in the switch.
View 1 Replies View Relatedi have a cisco switch CISCO Catalyst 2960S 48 GigE, 4 x SFP LAN Base WS-C2960S-48TS-L for this i need a 1GB GBIC Connector. need right GBIC connector module and ather details
View 1 Replies View RelatedI know there are some line cards on the 6500 that do not play well with each other when trying to setup an etherchannel using two different line cards on the same chassis. I always thought it was line cards of different type, i.e. 6400 with a 6700 but these two line cards are exactly the same model with the same code level.
1) Are the error messages below from this incompatibility between line cards and etherchannel creation?
2) How to fix if the answer to #1 is yes?
3) What line cards work with which for etherchannel creation?
I have a Cisco WS-C6513 switch, with a couple of GBIC module cards in it. I am trying to display the part number (or model number) of the modules which are inserted into this module card. How to do that? I don't want to schedule down-time to pull the module(s) - just to read the label! :-)
This shows me info for the "module card": sh module 9 But this doesn't work: sh module 9/6
I am trying to get a C2960-8tc-L linked to a sge2000p via the Gbic ports using GLC-SX_MM gbics but having no luck.Are these compatible and should I need to configure anything?
View 1 Replies View RelatedWe have a 6509 Sup2 at our ISP edge with fiber connection to ISP. I am planning on replacing the 6509 either with 7206VXR-GE2 or ASR 1002.
How do I find out what GBIC is installed on my Sup2 right now where Fiber cable is connected?What GBIC/SFP will be compatible for this on 7206VXR or ASR1002?If I use SFP do I need to change the cable connector?
I am having problems configuring a 4900. I have entered the following commands:
hw-module module 2 port-group 1 select gigabitethernet
hw-module module 2 port-group 2 select gigabitethernet
hw-module module 2 port-group 3 select gigabitethernet
hw-module module 2 port-group 4 select gigabitethernet
However no matter what I try, it never sees the GLC-SX gbics I have in the TwinGig converter.
PERSW001#sh interfaces status mod 2
Port Name Status Vlan Duplex Speed Type
Te2/1 inactive 1 full 10G No X2
Te2/2 inactive 1 full 10G No X2
Te2/3 inactive 1 full 10G No X2
[code]....
Is there any command to display the GBIC in the switch because I need to replace 3550 but I have no exact part number
the model is WS-C3550-24-SMI
and try
sh inventory
sh hardware
sh diag
sh module
Everything is in the title...When I plug a GBIC adapter on a port, my switch reload automatically..! Is it normal, because I did it during production and It disconnects some users.
View 0 Replies View RelatedThe module WS-X4306, support fibber fiber single mode ó fiber multi mode? what GBIC is for fiber single mode or fiber multi mode?
View 1 Replies View RelatedI am trying to connect a SF200-48 switch via Mini-GBIC MGBLX1 fibre module to a Cisco 3750 switch with a GLC-SX-MM fibre module installed both running a 1000 Mbps. When connected together they do not enable. Are there compatibility restrictions or is it that the Mini-GBIC modules cannot be used to uplink to a LAN?
View 2 Replies View RelatedI have a Cisco Router 881 with c880data-universalk9-mz.150-1.M7.bin IOS file. I want to upgrade to the latest IOS c880data-universalk9-mz.152-4.M2.bin. But when I upload the file, it appears the message The selected file c880data-universalk9-mz.152-4.M2.bin is not compatible with this router model.
View 4 Replies View RelatedI have a customer with an ACS for Windows version 3.3. I know the ACS is End-of-support, but if I could do Authentication for a WLAN with a Controller 5508 Softwareversion 7.0.116.0 and how?
View 3 Replies View Relatedcompatible LAN driver for M2N-MX SE PLUS
View 4 Replies View RelatedI wanted to confirm if the NM-2W is compatible with 3845 (says it is compatible) and 3945.I wanted increase WIC density in these routers to install ISDN HWIC-4B-S/T 4-port ISDN BRI High-Speed WAN Interface Card.However, i am not sure if these cards are compatible on the NM-2W. Is there any other NM* module that can extend WIC density on those routers.
View 1 Replies View Relatedjust a quick one, is the power brick for 877 compatible with 871?
View 6 Replies View RelatedI have a desktop PC running WinXP I recently got a laptop running Win7. I Set both of them up with the same workgroup name, and now my XP machine can see and access my laptop, but my lap can't see my XP machine. If it makes any difference, I can remote into my XP from my laptop, but that's not what I need.
View 3 Replies View RelatedI have wireless N router and just got wireless G usb adapter... but i dont get it to work.... can i manage to get it working or i need another adapter?
View 2 Replies View Relatedone side Catalyst 6500 module with X2-10GB-SR= otherside WS-C2960S-48FPD-L.
is both end compatible with each other.
i have confussion in my layout network design if this device working properly if i put this to my netwok. i want to config my router with 3 different subnet and in switch area i want to create 3 vlans with different subnet on each. may question is, is this posible for this kind of router to route my vlan network? here is the IP address i want to add in IP Table.
View 2 Replies View Related