Cisco Switches :: SE2010 - Does Firmware 3.0.2.0 Or 3.0.1.0 Has CLI Functionality
Jul 31, 2012
We just purchased this device and was curious if the firmware 3.0.2.0 or 3.0.1.0 has the CLI functionality like the Sx300 models with 1.1.2.0. I find it easier to configure via CLI then the WebUI.
View 3 Replies
ADVERTISEMENT
Apr 3, 2013
Region : Ukraine
Model : TL-WR1043ND
Hardware Version : V1
Firmware Version : 3.13.11 Build 121102 Rel.51321n
ISP : Volia
Is it possible to extend the functionality of USB in future firmware for data transfer? More detail about the problem [URL]can at least in beta partially implemented increase data transfer USB?I bought this router, and as all users lose .... With the Internet, download files faster than with external screw via USB.
View 4 Replies
View Related
Dec 15, 2011
With the new firmware (1.1.2.0) released for SG200 switches, is there CLI now?
View 4 Replies
View Related
Mar 2, 2012
Recently I brought SG 300-28.It came loaded with firmware ver 1.0.0.27.Can I upgrade it to ver 1.1.2.0 directly?
View 2 Replies
View Related
May 6, 2013
I have tried to update the firmware of my srw2016 but after this update my switch wouldn't start again.
It shows this message in my console:
Exit from boot menu. Continue with flow.
Preparing to decompress...
Image in address: 0x0 - Check Sum error!
Please download a new image.
Downloading code using XMODEM.
View 1 Replies
View Related
Jan 28, 2013
I did not know to update the boot software of my SRW2024 first, then update to 1.2.2b.I need to go back to the 1.0.0.86 firmware.
Is it downloadable and will it work (ie work backwards and then do it properly)? I know how to use hyperterminal and the xmodem protocol if need be.
View 9 Replies
View Related
Aug 13, 2012
I have just received a Cisco SF 200E-24P switch and need to upgrade the firmware. The current version is 1.0.0.12 an need to load the latest (or at least 1.1) to get CDP etc. However when I use the upgrade option in the switch I get an error of.Firmware Image download through HTTP failed. Wrong File Type.I have tried 3 different versions of the firmware and get the same error message each time.
View 4 Replies
View Related
May 8, 2013
I have downloaded the new firmware for the SG500. I see there are two files included in the download, a boot file (rfb) and regular firmware image (ros). I have looked and haven't seen anything about the rfb files. I know it is a boot file, but do not know if I should update the boot file first and then the firmware image or vice versa. Also, in my update screen on the SG500, the boot file option is greyed out.
View 1 Replies
View Related
Dec 12, 2011
We have Sg-300-28 serious switches(SRW-2024 k9-EU) and i want to upgrade switch with latest firmware, any info for latest firmware is used for the same ?
View 6 Replies
View Related
Jan 19, 2013
I'm trying to upgrade a switch SRW224G4 but without success. Model Name SRW224G4 Hardware Version 00.03.00Boot Version 1.0.0.06
I send the file via the XModem( SRW2xxG4_FW_1.2.3.0 ).
View 2 Replies
View Related
Nov 6, 2011
How do I get the actual firmware for SUBJ? On Cisco site only. 1.0.2 . However, As far as I know It have a 1.0.6 with lot of bug fixes.
View 1 Replies
View Related
Nov 11, 2012
I have just attempted to load the latest firmware on an SLM2008, everything appeared to work as expected BUT, the switch is no longer pingable on its static IP doesn't appear to have attempted get an address via DHCP. I have attempted power cycling the switch but it has made no difference. The switch is still switching but I have no management any more. What to do next ?
View 1 Replies
View Related
Mar 6, 2011
I want to remove the DD-WRT firmware from my router.It is a TP-LINK TL-WR740N V2.1 router.I want to set it back to its original firmware.
View 1 Replies
View Related
Mar 24, 2013
I have a SF300-24P switch running version 1.1.2.0 firmware. I want to get to the latest release (1.2.9.44) - can I upgrade directly to the latest code or do I need to step through all the versions in between?
View 1 Replies
View Related
May 5, 2011
I just purchased and installed this switch. It has firmware version 1.0.0.19 with boot version 1.0.0.1. I want to update te firmware to 2.0.0.8. Perhaps I am not doing something correct because when I try to update it I receive an error message that tells me the file is an illegal software format. Here is what I did. Under file format went to update firmware select http, update the chose the 2008.ros file. Start the upgrade but it fails.
View 1 Replies
View Related
Jan 4, 2012
We just upgraded our Sg300 series switches to the new IOS so we can get CLI access. The upgrade went fine but it seems we have two login prompts, the first being completely unnecessary as you can just hit return to get by it. IE here is the progression:
1. Connect SSH
2. Receive a "login:" prompt. Anything can be entered here, including just return
3. Login banner is displayed
4. Username Prompt is then displayed. Valid username required
5. Password Prompt displayed - Valid password required
6. Now at CLI 1. Connect SSH
I am trying to get rid of that first login prompt (IE Step 2) as it is causing issues with our configuration software. I have tried every line and authentication command I can think of, the only thing that gets rid of it is using none authentication which obviously we can't stay with. how did you get around it?
View 2 Replies
View Related
Jun 15, 2012
we are looking to use the new firmware's DHCP server feature to setup different DHCP scopes for 5 different VLANs configured on the switch. I see where to turn this on and setup the scope however I can't clearly see where I can assign the specified scope to each VLAN on the switch.
View 6 Replies
View Related
Jan 27, 2012
I am using the CISCO SG300-28 with firmware version 1.0.0.27. I enabled RADIUS authentication and accounting. Authentication is working but there are no accounting requests/replys (Accounting on, accounting off, accoun ting start, accounting stop) when running RADIUS in debug mode. I also did a packetcapture and there are no accounting packets.
So i updated the firmware image up to version 1.1.2.0. When I now want to configure accounting in RADIUS settings then there isn't any option to set an accounting port.
Ich checked the data sheet of the switch and it says that accounting is supported:
===============================================
802.1X: RADIUS authentication and accounting, MD5 hash; guest VLAN; unauthenticated VLAN, single/multiple host mode and single/multiple sessions [URL]
===============================================
I did a second packet capture with the new firmware image and there are still no accounting packets.
The RADIUS server is configured correct for accounting because when using another NAS like a WLAN-AP with DD-WRT accounting is workings. It is working with pfsense Captive Portal (an open source firewall and routing solution with a hotspot portal).
View 4 Replies
View Related
Apr 9, 2013
we are looking to use the new firmware's DHCP server feature to setup different DHCP scopes for 5 different VLANs configued on the switch. I see where to turn this on and setup the scope however I can't clearly see where I can assign the specified scope to each VLAN on the switch.
View 1 Replies
View Related
Jul 27, 2011
I've been having a problem with a brand new SG300-10 switch that I posted about yesterday. I checked the firmware and it was at 1.0.0.27 and the lastest is 1.1.0.73. So I backed up the current firmware and loaded the 1.1.0.73 version and it seem to be CLI based only, with no web GUI.
If so is there an easy way to reload the 1.0.0.27 using the CLI? There is nothing in the CLI docs that I can see unless it's buried.
The release notes for 1.1.0.73 don't say it's CLI only either, maybe something just went wrong but the CLI seems to be functional.
View 2 Replies
View Related
Oct 20, 2012
what is the process of updating firmware on a SGE2010.
I would usually use TFTP - but, I can't see the TFTP command on these SGE2010's
View 1 Replies
View Related
Jun 22, 2012
After performing a firmware upgrade on an SG300-20 switch from ver 1.1.0.73 to 1.2.5.70 the switch now boots up with the following error and resets:
30-Aug-2011 10:47:33 %L1Mngr-F-PARAMTOOLONG: csco-sb parameter %s is too long.
The attached file contains a full output of the console boot process. I have tried loading different versions from the console, but all produce the same error.
View 8 Replies
View Related
May 10, 2011
Have an SRW2024 that I was updating firmware and it got interrupted. Now I can't access the switch from either console or IP. Switch will not pass traffic. Is there a way to get this switch completely reset so I reconfigure and use it again?
View 1 Replies
View Related
Aug 31, 2012
I have a problem. Yesterday I have upgraded both my SG300-20 switches to firmware v1.2.7.76. Now I cannot login on of my switches, unknown username and password. I am absolutly sure I have the password, because they are the same and I just upgraded it. I have re-booted the switch, but without any luck.
View 1 Replies
View Related
Oct 7, 2012
Using the SGE 2010 for Microsoft NAP with 802.1x auth for switch access, which led to a few issues
What i have: An SGE 2010 48 port switch, firmware 3.0.0.17 Firmware upgrade: In order to ensure im not having problems due to old firmware, i tried to upgrade using ros_ls1_bp_ge_bx-3020.ros in order to move to 3.0.2, when uploading the file via TFTP, the upload completes and thats it, nothing happens.Restarting the device: As part of the upgrade process, i thought i might of had to reboot, so i rebooted, and found that all my settings were wiped clean, as if a factory reset had been performed.... and add further to pain, the backup of settings that i had taken do not seem to want to re-apply.NAP support: So i have tested my NPS (radius) server with NTRadping.exe and all is good, however i cannot get the SGE2010 to talk to it.... the authenticator state in the web interface is always listed as initialising.... im not sure if this is a simple incompatibility (hence the attempt at a firmware upgrade), a tag that needs to be set on the radius side or a switch misconfig.
1) how on earth do you upgrade the firmware?
2) why are none of my settings being saved when the device reboots ?
View 2 Replies
View Related
Apr 16, 2013
I have a question regarding SG300 series small business switches.If I switch between the two possible images, will the configuration get lost or is the configuration the same independent of which image I choose?
View 1 Replies
View Related
Jul 28, 2009
I have a switch SRW224G4 from Linksys and doesn't work now after an firmware upgrade!
Simple, here the result when I try to install the firmware "ls_106-12216.ros" or "SRW224G4P_SRW248G4P_image_v1020.bix" that came from your web site!
Here the result for "ls_106-12216.ros"
Calculating file's checksum...OK
Erasing FLASH ->>>>>>>>>>>>>>>>>>>>>>>>>>
[Code].....
View 12 Replies
View Related
Aug 14, 2011
I believe the SRW series is the same basic hardware as the SG300 series.Is there a way to upgrade the firmware on the SRW series using the SG300 firmware?
The SG300 firmware is much more usable. Also I'd rather have consistency as we have the older SRW2024/48 and the newer SG300 switches.
View 2 Replies
View Related
Dec 12, 2012
with TFTP upgrade SRW2xxG4_FW_1.2.3.0.ros and WEB interface after the restart, the switch will not start, display HyperTerminal link. You can also restore the switches do not?
View 1 Replies
View Related
Jan 3, 2012
I have downloaded the ros file, but can't find how to apply it. I know this information must be out there, but can't find it.
View 2 Replies
View Related
Mar 28, 2013
I installed the 1.3.0.59 on a couple of SG300-28Ps. On the Status and Statistics page, the PoE indicators no longer lit. Physically, on the front of the switch, they did still light. I didn't yet reboot to factory defaults to see if that clears it, because I don't feel like entering the config again this early in the morning. But I am willing to test that, if needbe.
When reverting the image back to 1.2.9.44 (tested) or possibly earlier, the ip default gateway must be re-entered (if it was configured). Even if ip-default gateway x.x.x.x shows up correctly on a 'show run', the switch will not obey it, and on the IPv4 settings page it will report the operational default gateway as blank. This came as a surprise becauset he switch suddenly wouldn't talk to the VPN anymore.
Logging onto the switch locally, going to the IPv4 settings, ticking the radio button back on User Defined and typing it back in cleared that up. It appears this cropped up because the syntax for specifying the default gateway changed in 1.3.x but it's still odd that the config shows correctly in console but not in the gui.
View 19 Replies
View Related
Nov 2, 2011
choosing Ios for a funcionality.
We need to upgrade Ios in a 6509, the reason for we need to upgrade IOs is that we need implement the command xconnect in a interface. The current version of Ios not suport this comand.
How do we select the new IOS that suport this command?, ..we see a long list of IOS in the software download section of 6509, but not sure which one to choose..
View 2 Replies
View Related
Oct 19, 2010
With lms 3.2 during installation we can choose what to install i.e. not install DFM or IPM.
How can we do this in the new release 4.0 of the LMS bundle. I saw no options for it during installation of the new server.
View 3 Replies
View Related