Cisco Switching/Routing :: 3925ISR Backing Up IOS And Configurations From Ether-switch Module
Jul 10, 2012
I am trying to research the possiblity of backing up IOS and configurations from an Etherswitch module, and being able to store the files onto the Host Router's flash (3925 ISR). and then being able to recover that IOS and configuration, in case I have to replace the Etherswitch Module.
I have one 3945 router with SM-ES3-16-P module with SL-ES3-16-IPS. I am not seeing any license for this module in CLI output of my router. How do I add license for this module and activate. do I need IP Service IOS for this module
I try to connect a cisco blade switch 3020 to Nexus 2232 with etherchannel, but when I connect the second link a obtain flapping on vlans. [code] why the vlans are flapping ? it's something wrong on the config ? [code]
I have 4 cisco 2960 switches to which many users are connected. No vlans are the only default vlan 1 is there. Now I want to make ether channel on switch 1 whcih has 24 fast etherenet ports. Can I make port 1- 8 as one ether channel which are connected to users or i can only make ethere channel of ports that are connectd to other switchs. If I can, how the other switchs will comnicate with the switch ports bundalled in the ether channel in switch 1.
I have version 2 ssh configured on a Cisco 4507r-e. Unable to sync archives with CiscoWorks. V2.99 is unsupported on CiscoWorks. Does CiscoWorks need to be updated or does the switch?
cat4500-ipbasek9-mz.122-52 LMS 3.2 # show run ip ssh version 2 #show ip ssh SSH Enabled - version 2.99
Suffered a big outage on the network, the fix was to reload the module 3 on the 6509 switch, we had these errors on the log %CONST_DIAG-SW1_SP-3-HM_PORT_TEST_FAIL: Switch 1 Module 3 TestUnusedPortLoopback Port(s)[24,46] failed. System operation continues.in the end, we reloaded the card and it was all ok. is there anything I can do to check the card / or any deeper logs? would that error cause the card to crash?
I'm trying to set up a 2951 with a 24 port switch module. I want the ports to act similiarly to the ports on an 881 router - where I assign the VLANs on the router and I set the VLANs to the switchport interfaces.I would like to be able to create the VLANs on the router portion of the 2951 and then, enter the switch module and configure the Ports to the VLANs but, how do I logically connect router to the switch? Is it an internal logical interface - meaning how are the VLANs getting from the router to the switch?
We have supplied Cisco Swtch 2960 with gig SFP modules. It is working fine. However, when I do a show inventory it show proper part no. for the switch chassis but for the GLC T module it shows as unspecified in the PID column.
I have a problem with a newly bought ws-x4548-rj45v+ i've plugged in the module but when i do show modules all , it show as unsupport
Power consumed by backplane : 0 Watts Mod Ports Card Type Model Serial No.---+-----+--------------------------------------+------------------+-----------1 2 Supervisor IV 1000BaseX (GBIC) WS-X4515 JAE1048GAXQ2 48 10/100/1000BaseT (RJ45) WS-X4448-GB-RJ45 JAB064806WN3 48 10/100/1000BaseT (RJ45) WS-X4448-GB-RJ45 JAB063005DB4 0 Unsupported module WS-X4548-RJ45V+ JAE1545056U M MAC addresses Hw Fw Sw Status--+--------------------------------+---+------------+----------------+---------1 0007.0e64.f880 to 0007.0e64.f881 5.2 12.2(20r)EW1 12.2(46)SG Ok2 000b.5fa4.da20 to 000b.5fa4.da4f 1.0 Ok3 0009.e844.d760 to 0009.e844.d78f 1.0 Ok4 ccef.4815.9bf0 to ccef.4815.9c1f 2.0 Unsupport
My questions is can a 4 port PoE switch module (EHWIC-4ESG-P) and a 8 port switch module (EHWIC-D-8ESG) be used at the same time in a Cisco 1941 router?
I have a laptop with a single physical NIC which I have used the advanced management tools to create two virtual NICs (say vlan 10 and vlan 20) and both are on the same subnet (say 192.168.4.x). One NIC is for normal TCP/IP traffic and one is for broadcast/multicast traffic (I have some custom software that requires this to be the case and works fine on an older laptops with built-in physical NIC and PCMCIA XIRCOM NIC). The dual NIC laptop communicates with a dual NIC server via a Cisco 2811 router (which has a 16 port switch module at the back) and has vlans set up so.
What I want is for the single NIC laptop (with two virtual NICs) to be able to also communicate with the server. Basically, one NIC is for normal traffic and one is for multicast/broadcast traffic. All three machines need to be able to talk to each other using the NIC for normal traffic and both laptops must be able to receive broadcasts from the server. What is the best way to configure the router to handle the trunking/tagging? Most configuration documentation I read has two complete subnets for the two virtual NICs. Note that all three machines use static IPs and are part of a workgroup so no DNS and domain servers etc.
Trying to find some documentation as to whether there are any other steps for inserting this new module in our N7K. We have 2 blades in already and 2 Sups in 5 & 6. I'm assuming its like the 6500s, where we just slide it in and the OS configures the global parms for it and the default VLAN.
We having a VSS switch (9 slot chasis) with ios "s72033_rp-ADVENTERPRISEK9_WAN-M), Version 12.2(33)SXI4", slot 7-9 are currently free. We wanted to install WS-X6708-10G-3C module on slot 7. Once we installed the module it didnt come, after waiting for 15-20min again we removed and inserted, but module didnt come up and we could see following logs on the console:
Jan 12 08:57:40.146: %ISSU-SW2_CFC2-3-ERP_AGENT_SEND_MSG: client/entity send failed; error code is timeout *Jan 12 08:57:40.330: %ISSU-SW2_SPSTBY-3-ERP_AGENT_SEND_MSG: client/entity send failed; error code is timeout Jan 12 08:57:40.146: %ISSU_ERROR-SW2_CFC2-3-START_NEGO_FAILED: ISSU NTI Client(2040): failed to start negotiation (ISSU_RC_CLIENT_ENTITY_DOES_NOT_EXIST_IN_PEER)
[code]....
Afer some time VSS switch didnt response to console commands and all the users in access switches were not able to reach the gateway (VSS). Then the problem disappeared once we rebooted both the switches in VSS.why the VSS switch become non-responsive?
can i use any downlink port of the C4500-X switch as uplink without the need of the network module?i need to connect that switch to C6500E backbone without getting the network module, is that OK or i must get the network module?
how this switch module works in 2911 router? I have two 2911 routers in HSRP configuration for redundancy with crossover cable between switch modules. OSPF running on routers.If active router loses its power and then comes back again, it boots first, its internal link to switch module comes up and it starts to forward packets to switch module. The switch module starts to boot only after router is ready. So I have outage of about 3-4 minutes. For our real-time applications it is way too long.
any way to start booting of the switch module before router gets ready?I understand I can boot it manually, but it is only after router is ready. Only way to get around it I found is to disable internal link and use router interface to connect to the switch module.
After a power problem at our data centre we find Module 11 of our Cisco 6513 Core Switch in PWR Down state.Show Module 11 returns: Status: PWRDownShow Power Status Module 11 returns: OperStatus Off (Module Reset due to an exception or user request).The command: Power enable Module 11 was issued and returned the following: %PM_SCP-SP-1-LCP_FW_ERR: System resetting module 11 to recover from error: Linecard received system exception. Errcode = 2509000001.%OIR-SP-3-PWRCYCLE: Card in module 11 is being powercycled Öff (Module reset due to exception or user request%C6KPWR-SP-4-DISABLED: Power to module in slot 11 set off (Module Reset due to exception or user request),We have restarted the switch twice. The module is currently not passing traffic causing downtime to services.
switch catalyst 4500 with ios cat4500e-universal.SPA.03.02.00.XO.150-2.XO.bin. I need to configure modules 3 and 4 of supervision, the problem is that I need the 4-port module 3 are active but only the first turn on both the module 3 and the first port on the module 4. [code]
I have a 3925 Router with a 48 port switch module (part number SM-D-ES3G-48-P). I have no problem accessing the 3925 Router, but when I go into the 48 port, I get an error that reads
Error Hardware not supported by firmware. Try loading a newer software instead. System Resetting...
I know that the wrong IOS is installed on the switch, but the problem is that this is an endless loop. The switch resets then comes back to the same error. How to get the switch out of this loop so that I can load the correct IOS.
I have a supervisor blade, (VS-S720-10G-3C), in a 6513 that is faulty and needs replaced. Do I need to replace the IOS on the new supervisor blade to make sure it is the same as the IOS image that is on the Active supervisor module, or will it synchronize automatically?
In the synchronization process, the active supervisor engine checks the standby supervisor engine run-time image to make sure that it matches its own run-time image. The active supervisor engine checks three conditions:
# •If it needs to copy its boot image to the standby supervisor engine # •If the standby supervisor engine bootstring needs to be changed # •If the standby supervisor engine needs to be reset
I was reading the above documentation that mentioned the active supervisor should copy the image if it detects a newly installed standby supervisor blade with a different image, is this correct or was it referring to synchronizing the configuration file?
I have a 1941 that I am going to deploy with a HWIC-D-9ESW switch module (I only need 3 switch ports but need the PoE). I am going to hang a 1262 autonomous AP off one of the ports but I need to configure MAC address port-security so that only that AP can pass traffic. I know the switch modules are 'almost' exactly like a switch for commands but I can't seem to enable or configure any port-security settings. Is port-security no available on the switch modules?
We are working with a contractor to upgrade our network, and I heard from them that the 5596/5548 might not need the Layer 3 module for our inter-VLAN routhing. They have yet to give me an answer.
We do have a few static routes on our current layer-3, core switch too.
Recently I have faced following problem in my office, We have purchased two new Dell Server Power Edge R910 with built-in 10GB FC Network card. Service tag of this two servers are given bellow. 1. 7D94C2S 2. 6D94C2S You can can Check specification of this two server from dell website{ URL}
We have two CISCO switch and model is given bellow: Brand: CISCO Model: WS-C3560E-12SD
We want to connect server to switch through FC cable and both switch have SPF module. But when we connect server to switch, link do not establish even switch and server port light become off. Then we have tested the following things: 1. Connect server to server through FC cable, it is okay. 2. Connect switch to switch through same FC cable, it is okay.
I have 6 of these WS-CBS3012-IBM modules that need to be configured but I cannot access the USB console port. I was told I could just get any DB9- to- USB cable and that would work. I did buy a DB9-to-USB cable and it did not work. I looked up the installation guide for this module and it just said the console cable is DB9-to-USB but with no part number.
I was configured ether channel between two cisco 2960s series switches. It is working properly. I was replaced two cables in etherchannel. Now one link working remaining link is down(both cables are working cables only). Below are ether channel details.
running ether-channel mode on. I have a 3120G Blade Switch (stacked). The blade switch connects to the blade servers (internal). Gi1 /0/1 connects to eth0 and gi2/0/1 connects to eth1 on the blade server. [code]
The issue is when is shutdown eth0 on the server, the corresponding interface on the switch (gi1/0/1) does not go down, show up and running.
I have a problem with x4648-rj45V+E module, which is not forwarding frames/packets in my 4507E switch. I have done the diagnostic and the module test is passed. When i try to ping from one PC to another in the flat network, icmp is not forwarding. Even i cannot see the mac addresses in the mac address-table. But i can ping to my management port in the sup module?
I want to connect WS-C2960S-48TD-L switch to WS-X6708-10G-3CXL module in Cisco WS-C6503-E switch. WS-X6708-10G-3CXL is C6K 8 port 10 Gigabit Ethernet module with DFC3CXL which requires X2 module. on the otherhand, WS-C2960S-48TD-L requires SFP+. Now is it possible to interconnect these two switch interfaces if I use LIU in between. or does WS-X6708-10G-3CXL module supports CVR-X2-SFP+ to use SFP+ transceivers.
I came across a Catalyst 6509 switch configuration and have noticed some strange thing on the ether channel configuration side, it appears that it have interface port-channel 2 and port-channel 2A, what was that mean? its the ether channel not forming and joined together?
What wrong with the below configuration that cause it to automatic created another port-channel (2A) interface in this case?