Cisco VPN :: 2800 - Tunnel Not Coming Back Up After Power Cycle
Apr 15, 2013
Cisco 2800, 12.4(23b) router has two VPN tunnels to other Cisco devices.
Authentication uses certificates from a PKI CA server. Under normal circumstances all works fine, both crypto sessions up.
After a power cycle (having first saved configs) however, the crypto sessions are stuck in DOWN-NEGOTIATING.
The certificate on the router still looks valid.
The only way to get the sessions back up is to renew the certificate, which seems strange as the existing one appeared to be still valid.
View 5 Replies
ADVERTISEMENT
Aug 15, 2012
We have a Model WRT54GLWireless-G router. At least once a day it loses it's internet connection. All computers that are wired to the switch that is connected to it lose their internet as well as any wireless devices. I have to manually power-cycle the router to get internet back.
View 9 Replies
View Related
Nov 21, 2012
For some reason when I'm watching a HD video or I'm downloading a file, on my HP laptop my wifi decides to stop,disconnect and then start up again This never occurs on my iPhone iPad Xbox or any other laptops in the house.
View 1 Replies
View Related
Apr 17, 2011
I have the following equipment
1 x AIR-WLC-2106-K9 (IOS = 6.0.199.4)
4 x AIR-LAP1131G-E-K9 (IOS = 12.4(21a)JHB1)
All configued ok with 2 SSID's associated to 2 VLANS all operates as expected.However every few 2 to 12 hours the WLC crashes, locks up.Unabale to contact via telnet or browser, will not respond to ping.The LAPs remain up but the WLANS go off air etcOnly a physical restart of the WLC will bring it back.
View 14 Replies
View Related
Nov 14, 2012
I'm having a little issue with some Cisco Aironet1242ag WAP's. I receive a call at least twice a month stating that some of the WAP's are not giving out internet connection. What I always do is go to my patch panel and disconnect those WAP's not working and connect them back again so they can power cycle. These WAP's are connected to a Cisco3750g. Once the WAP's boot up, the users can connect to the WAP and connect to the internet.
I don't know if these WAP's are filling up with some information that causes the access points to not connect to the WAN.
View 7 Replies
View Related
Jun 13, 2012
recently bought a new Linksys EA3500 that is connected to my SB5120 cable modem. For two weeks it's been running smoothly but when my cable modem is in need of a power cycle.I power cycle both the router and modem but my connection is lost. it's after countless hours of messing with the two I'll get the connection back but I'm afraid it'll lose connection again, that and I fear I may have enabled bad options.
View 10 Replies
View Related
Nov 27, 2011
I have access controls setup on my DIR-825 which work fine until there is a power outage and my router comes back up.I am using Automatic Time Configuration and have the NTP server set to ntp1 [URL]When the router comes back up I checked to make sure the NTP server option is still enabled, and it is, however the current time is totally wrong.To fix this I had to go to the pull-down, select 'ntp1.dlink.com' and then save the settings. After this the time is correct again.This is as bad as not having the Automatic Time Configuration option at all, since I can't guarantee that the power won't go out. I do not have a UPS hooked up to back up the router, nor do I see why I should need one if the Automatic Time Configuration actually worked.know if there is a way of making the Automatic Time Configuration reliable so the time on my router is automatically corrected when the power comes back up?
View 3 Replies
View Related
Aug 1, 2011
It seems there's no way to reboot this device from the browser interface. You have to actually go and recycle the power by physically pressing the button.Plus, to setup Port Forwarding you have to reboot the modem.This is a major problem because it means you have to be on the premises to change things like the port forwarding. You setup it up, but have to reboot for it to take effect.
View 1 Replies
View Related
Jan 24, 2013
I have a Cisco 1841 Router with ADVANCE IPSERVICE IOS .The said router does not safe config, even after saving the config? As soon as the power cycled all the config will be lost? what can be done to correct this ?
View 1 Replies
View Related
Aug 27, 2012
We have some 1242 LAPs in a two 5508 controller setup working fine. All LAP are configured to obtain address from DHCP. After first join we usually change some configs like HOSTNAME, AP GROUP, PRIMARY AND SECONDARY WLC. After a software restart or a complete power off/power on the LAPs joins the primary controller and all configuration still there. We now add a 1142 LAP and is does not retain the configuration after a power off/power on cycle, but after a software restart there is no problem. The only way to retain the config is setting the AP with a static IP address.
We use WLC 7.0.116 and we see no errors in the LAP console.
View 1 Replies
View Related
Dec 25, 2011
while ago, I got a virus that tried to mimic windows activity center. Since then, I have use malwarebytes anti malware, ccleaner and microsoft security essentials to scan and remove the virus.Usually what happens is that I will be using firefox, and all of a sudden most of my programs would exit, and one of those fake virus scanners come up (Microsoft security essentials also turns off if that is important). I open the task manager, and identify the program. I open explorer (as i can't open mbam, or mse) and delete the file. While it is in the recycle bin, I can open mbam (for some reason, it asks what program to open mbam with, I just pick mbam from the list) and I scan, and remove the threats. Then I empty the recycle bin, and use ccleaner to fix the registries. Lastly, I use mse to scan the computer.Everything works for a while until it comes back again....and again....and again. I've tried the same steps in safe mode and again in regular mode. It's still happening.
View 9 Replies
View Related
Jan 20, 2011
I've setted the unit in BRIDGE MODE, and attached on it 3 LAN devices, 1 PC Desktop, 1 NAS WDBE and 1 HP printer ... OK all config process was right and all my units talk togheter via AP Netgear DNG2000, and so i can use for instance the printer with my laptop too connected in WI-FI N. Now usually, In the night I turn off all my devices (DAP included), and when in the morning I need only the printer used by my laptop, obviously I turn on ROUTER - BRIDGE - PRINTER - LAPTOP but NOT the DESKTOP ... and so the DAP can't reconnect automatically to the router (both the lights AP/BRIDGE are on and fixed) ... I turn on the PC and the BRIDGE reconnect to the world .... BUT I DON'T WANT turn on everytime the desktop !
1) all gears has fixed IPs
2) DHCP server deactivated on the AP main router (DNG2000)
3) no WPS used, only WPA2-PSK (AES) personal keys on all gears
once that DAP-1522 is connected to the router .... all work fine (also when I turn off the DESKTOP).so the workaround is never turn-off the DAP ? I can't believe ... and who will save the energy planet
View 2 Replies
View Related
Jun 11, 2012
I've just bought a pair of WAP121 for testing and validation. I've set it up properly (user/password, IP, management vlan, NTP, SNMP, 802.1x, etc). So far, so good, everything worked as expected. I've downloaded the configuration to my PC, and also saved it to startup-config. I've powered off the unit, went for a coffee, and powered it back. All my settings were lost.
Tried to restore settings from the file downloaded to my PC, but no luck. After reboot, it was factory clean, no trace from settings in the backup file. I've set it up again by hand, power cycled it, and the **** thing reloaded to default settings.
Faulty unit, I thought, so I opened the other one I have, and repeated the whole thing, but same results. Test were made using the power adapter supplied but also tried with a catalyst 2960 with PoE.
View 3 Replies
View Related
Dec 9, 2012
When our DSL modem drops its connection, even momentarily, the RV220W requires a power cycle before the computers on the LAN can browse again. When I connect to the router, the WAN Information displays the word Connecting, rather than Connected.
We have a DSL modem connected to the router, the router connected to an ethernet switch, and our small business pc's connected to the switch.
Firmware on the router is 1.0.4.17
View 4 Replies
View Related
Jan 19, 2013
I have an E1200 and if a device - such as my tablet or laptop - is left unused for a period of time - say for 4 or 5 hours - they won't reconnect to the router unless I do a power cycle/reset on the router.
View 5 Replies
View Related
Feb 22, 2013
We have configured Cisco 3750X POE series switchs with Stack.WS-C3750X-48P each with Redundant 1100W & 715 W PSU's. They are configured with Stack-Power in Sharing mode and the switches are Smart Stacked as well.IP Phone and Access points are connected its working in last two years,
Now we are facing some issue on Cisco IP Phone and Access point, When i have problem if unplug (disconnect & Reconnect) the IP Phone from Switch port,Power is not comming on switch port.Plug it into another switchport of the same Switch it may not power in any port.I tried shut & no shut and reconfigured on switch port , I have verified multiple switch ports same issue on the switch I have changed cable.
View 2 Replies
View Related
Apr 6, 2012
Having a strange issue here with an 7606-s chassis equipped with two sup720's, and two regular line cards. There is only one power supply, PWR-2700-AC. I recently builded this setup and powered it on last week for the first time. It ran fine for about 20 minutes while suddenly the chassis powered down.
I've checked the back of the chassis and noticed that the power supply had it's 'input ok' and 'power fail' led lit. I toggled the power switch and waited half an hour to power it on again. This time only 1 minute of joy. My first idea was the PSU due to the power fail led so I had it swapped by the supplier for another. Unfortunately, when I powered it on today, it didn't change a thing, still unexpected power downs.
So I've checked the following documentation: [URL] and followed the suggestion to power the chassis on without any modules in the slots. So I did that and it ran for 8 minutes only. However, the fan tray did respond properly when I removed the small thermal module in the upper right by increasing the fans to full speed.
Following above documentation, it points to the chassis (there is not much left). Now the real question comes, isn't there anything else that could be the cause of this?
View 1 Replies
View Related
Feb 6, 2012
We have problems on central firewall with restricting traffic coming from remote office from IPsec. (The network sheme is attached) All branch offices are connected to central asa though IPsec. The main aim is to rule access from branch offices only on the central firewall, NOT on each IPsec tunnel According to the sheme:172.16.1.0/24 is on of the branch office LANs10.1.1.0/24 and 10.2.2.0/24 are central office LANThe crypto ACL looks like permit ip 172.16.1.0/24 10.0.0.0/8 the aim is to restrict access from 172.16.1.0/24 to 10.1.1.0/24 When packets are generated from host 10.1.1.10 to 172.16.1.0/24 all is ok - they are dropped by acl2 When packets are generated from 172.16.1.0/24 to 10.1.1.10 they are not dropped by any ACL - the reason is stateful firewall - traffic bypasses all access lists on a back path I thought that TCP State Bypass feature can solve this problem and disable stateful firewall inspection for traffic coming from 172.16.1.0/24 to 10.1.1.0/24, but it didn't work.The central asa 5500 is configured according to cisco doc [URL]
access-list tcp_bypass_acl extended permit tcp 172.16.1.0 255.255.255.0 10.1.1.0 255.255.255.0
!
class-map tcp_bypass_map
description "TCP traffic that bypasses stateful firewall"
match access-list tcp_bypass_acl
[code].....
View 4 Replies
View Related
Jul 12, 2011
Only because we want to updeate A/C system in server room, we need to know what Cisco 2800's the power usage and heat output are. It is on the racks and can't see its spesc.
View 1 Replies
View Related
Jan 12, 2012
i am trying to set up a tunnel connection between twO 2800 routers A<->B
1) destination ip is-204.x.x.x-ROUTER A2) source ip is 166.x.x.22-ROUTER B The router B has the modem connected to GE0/1 whose interface ip is 166.x.x.22 The ip-forward-protocol nd is configured as below
ip route 204.x.x.x 255.255.255.255 166.x.x.21
Also tunnel 1 configuration,isakmp policy are configured properly when i run show crypto isakmp sa it shows MM_NO_STATE,i checked the preshared key on both ends and they are same.whenever i remove the ip address of the interface Ge0/0 and ip route i can ping the 166.x.x.21 which is the modem gateway.when i revert back the configuration to the above ,the ip 166.x.x.21 cannot be pinged,the dsl connection is live though.ways to fix this so that i can make this tunnel state to QM_IDLE?
View 1 Replies
View Related
Oct 3, 2011
Any problem/issue with using 28VDC to power the 2811 router. The spec calls for a 24VDC power.
View 1 Replies
View Related
Nov 22, 2012
I am having a hard time trying to configure DMVPN with the tunnel being sourced via a loopback interface. All routers are Cisco 886 routers which don't have L3 ports.That is why I used SVI interfaces, and have configured the L2 ports (Fa0, Fa1, etc.) with the command switchport access vlan.The problem is that I am receiving Invalid SPI error's only on the Hub router and I have no clue what could be the problem, because they use exactly the same parameters for IPsec. [code]
View 1 Replies
View Related
May 5, 2011
Equipment Cisco1921, HWIC-1ADSL, 2 x GB Ethernet interfaces (Only one used for local LAN) Software IOS Version 15.1(1)T2..I have been asked to configure this router to provide an IPSEC tunnel back to our central office.We have been provided with an ADSL business class 7MB service from Telecom Italia, they have presented the circuit to our office with no terminating equipment (wires only). Telecom Italia have provided us with some IP addressing information as follows (I will not disclose the entire IP address) [code]
I can see that the packet count is increasing both inbound and outbound on the ATM interface. I have read many documents and tried many different way to try and get this resolved, I even logged a call with Cisco but no dice.
View 5 Replies
View Related
Nov 8, 2012
I have a Linksys E2500 and recently the power led light on the back of the router started blinking. The router itself seems to be working fine. I can access the router and the router seems to be assigning the IP addresses fine. I did look up the issue on the knowledge base and tried all the solutions but the light is still blinking. Not sure what to do anymore.
View 5 Replies
View Related
Oct 10, 2012
I'm able to build my tunnel but unable to RDP nor ICMP back to the internal network.
VPN Client IP: 192.168.200.200
INTERNAL IP: 172.17.130.200
my configuration is below:
HOME-ASAFW02(config)# wr t: Saved:ASA Version 8.4(4)!hostname HOME-ASAFW02domain-name hsd1.nj.comcast.netenable password ViPq56cvd3SGvB08 encryptedpasswd 8bcozHCAwCqA5BmN encryptednames!interface Ethernet0/0description OUTSIDE-Connectionswitchport access vlan 2switchport protected!interface Ethernet0/1description INSIDE-Connectionswitchport protectedspeed 100duplex full!interface Ethernet0/2description WiFi-LinkSYSswitchport access vlan 3switchport protected!interface Ethernet0/3shutdown!interface Ethernet0/4shutdown!interface Ethernet0/5shutdown!interface Ethernet0/6shutdown!interface Ethernet0/7shutdown!interface Vlan1description INTERNAL-Networknameif insidesecurity-level 100ip address 172.17.130.129 255.255.255.128!interface Vlan2description OUTSIDE-Link-to-ISPnameif
[code]....
View 12 Replies
View Related
Sep 20, 2011
Can i know cisco 2800 router can support how many site-to-site ipsec tunnel without vpn module?
View 2 Replies
View Related
Apr 27, 2013
I have a Linksys WRT54G2 v1 router which is having a daily problem of connectiing to the Internet on my home wireless LAN. My temporary solution is to disconnect the power from the router for about 15 seconds and plug it back in .... and all is well.... at least for another day or so.The real problem is that instead of properly connecting to IPv4 address 192.168.1.100 ..... it randomly connects to Autoconfiguration IPv4 address 169.254.29.54 When this problem occurs the SSID list shows both my 192 connection as well as a public network with no Internet connection?
I've used this router for several years without a problem until I recently bought a new Canon wireless MG5320 printer which initially had problems connecting to my LAN. After a telco with tech support the printer works fine but now I am now experiencing the Autoconfig address problem.My LAN consist of the WRT54G router, a Motorola cable modem, a Lenovo laptop running Win7 64bit, a Hp desktop running Win7 64bit and the Canon wireless printer. (all connected wirelessly)
View 2 Replies
View Related
Nov 25, 2012
I have a Cisco 8510msr that is connected back to back with a 7206vxr across a 155Meg connection.I receive lots of Output drops on the 7206vxr interface facing the atm switch. When I do the following command:-
kwdair9#sh atm int atm 1/0Interface ATM1/0:AAL enabled: AAL5 , Maximum VCs: 4096, Current VCCs: 27 Maximum Transmit Channels: 0Max. Datagram Size: 4528PLIM Type: SONET - 155000Kbps, TX clocking: LINECell-payload scrambling: ONsts-stream scrambling: ON797522 input, 881483 output, 203946630 IN fast, 223768062 OUT fast, 0 out dropVBR-NRT : 110288 Avail bw = 44712 <====
I only have 44megConfig. is ACTIVEkwdair9# I only get 44Meg of the available 155Meg.There is no QOS on the router and the only commands I can find that vaguely see that refer to QOS are on the ATM switch:-
atm address 47.0091.8100.0000.0007.0d87.b201.0007.0d87.b201.00atm router pnnino aesa embedded-number left-justifiednode 1 level 56 lowest redistribute atm-static?why this is acting like a DS3 link and not a 155Meg link?
View 4 Replies
View Related
Dec 4, 2011
What cable I need to connect two 2951 back to back through a HWIC-4T1/E1 card ?
View 1 Replies
View Related
Apr 11, 2013
I have two site that has a copper wire ( 2 wire) connection between each router ( No Telco in between ). Now I want to use 1921 router with HWIC-4SHDSL-E card to connect these two site together. Can I use attach configuration to make the connection reference from the diagram ?
View 1 Replies
View Related
Nov 25, 2011
I have 2650XM router and 2620 Router Both routers have built in WIC T1 CSU/DSU cards
2620Router --
2620Router#sh int se0/0
Serial0/0 is down, line protocol is down
Hardware is PQUICC with Fractional T1 CSU/DSU
Description: DTE side
MTU 1500 bytes, BW 1544 Kbit, DLY 20000 usec,
reliability 255/255, txload 1/255, rxload 1/255
Encapsulation HDLC, loopback not set
[code]....
My question is that cisco website says there are two type of cable connections for this type of config --which are --T1 CSU/DSU ConfigurationSet one CSU/DSU to clock source internal, and the other CSU/DSU to clock source line. The linecode, framing, data-coding, and timeslots must be set the same on both CSU/DSUs.Four-Wire 56k CSU/DSU Configuration For my network connection which type of config i should use??Secondly i try to connect these ports by normal crossover cable it did not work.So for this type of connection i know i need T1 cross over cable-- which has RJ 48 connections at both sides.I check cable from ebay which is RJ45 RJ48 cross over -- will this cable work in my router to router connection.
View 5 Replies
View Related
Oct 19, 2012
I have 1 2611xm router and 1 2801 router. For my own lab purpose, i want to configure them back to back to support voice services. I don't know what configuration will be required at each end. in 2611xm, i have NM-2V and its also detecting the card, so i hope it will work ? also what commands i need to run on both ends .
View 1 Replies
View Related
Jan 8, 2013
I would like configure two router (e.g. 1921) back to back via a 2 pin copper wire. Can I use HWIC-4SHDSL-E card to do it? What is the configuration I can use?
View 7 Replies
View Related