I have a Ethernet module (SM-ES3G-16-P) installed in a 3945 router and noticed during first boot no licenses are active at all. I would assume at a mimimum ipbase would be active. With this module, does static routing work with just ipbase?
Example:
interface g0/1
no switchport
ip addr 192.168.254.2 255.255.255.0
We have Cisco 3945 Router with SM-ES3-24P Switch Module. when we tried to configure routing in Router and Layer 3 ports on Switch module, the inter-communicaiton is not working?
how we can use routing in 3945 with SM-ES3-24P module?
I have one 3945 router with SM-ES3-16-P module with SL-ES3-16-IPS. I am not seeing any license for this module in CLI output of my router. How do I add license for this module and activate. do I need IP Service IOS for this module
RouterModelIOSModuleR1Cisco 3945 Integrated Service Routerc3900-universalk9-mz.SPA.151-1.T.binNME-AIR-WLC12-K9 R2Cisco 3945 Integrated Service Routerc3900-universalk9-mz.SPA.151-4.M1.binNME-AIR-WLC25-K9
The issue that we are experimenting is that, although the module's interfaces are up and HSRP in correctly configured, the show standby summary displays that the Active router is local in both routers. We also have some GigabitEthernet in the routers and they are correctly running HSRP. Does the WLC Modules physically support HSRP?
I've a 3945 with SM-ES3G-24-P module installed and tried to configure some routing but it doesn't work .
1. L3 interface on the switch modules (with ip address configured) 2. OPSF on the router with connected interface redistribute (which includes the switch module L3 interfaces)
I don't see any of the switch module L3 interfaces routes in the router, not even the connected interface.
SM ----- int g0/1 no switchport ip add 1.1.1.1 255.255.255.0
Router --------- int g0/0 ip add 2.2.2.2 255.255.255.0 router ospf 1 redistribute connected network 2.2.2.2 0.0.0.0 area 0
We just recently purchased a 3945 ISR G2 router and have a SRE-910 module (with two hard drives) configured in a Raid 1. We are running a stand-alone version of ESXi on the service module and I'm trying to figure out how to monitor the status of the Raid on the drives (along with other health issues). SNMP has revealed nothing so far and even opening a support case for which MIB's to use has proved fruitless. All the documents I find on monitoring the modules say to use LMS which is now Cisco Prime. I've downloaded the trial copy, put in the SNMP settings and scanned the router. I get device results and it shows that I have the SRE-910 module installed, but I get no other configuration / device informaiton from the module itself.
I tried to create a new Monitoring template using the NAM health as the base template (which I'm assuming this is the correct template). Unfortunately, when I actually try to deploy the template against the discovered router, I get an 'Unexpected end of list' error which makes me assume I'm still doing something wrong.
I was wondering if I could use the CISCO3945 Integrated Gigabit Ethernet WAN ports for routing, I need to enable BGP and I was willing to use one of those ports.
I'd like to establish a more robust border router/switch redundancy plan and would like to know if this seems like it would be reliable.I'm looking at using a couple of 3945 routers and 3750 switches in the configuration shown below.
The article found at [URL] outlines the config between a single switch and router but I am looking at doing this with dual routers and switches.
We are having problems with a two router 3945 in HSRP and a switch 2960.The two routers are connected to the switch 2960 through differentes ports. The problem is that we loose connection between the router and the switch.When we excute the command: show cdp neighbor at router, it shows nothing.If we try to make ping to the 2960 switch it is no reachable.If we make ping to the other router 3945 it is not reachable.All other function of the router are o.k.We are attaching the IOS of the routers and switch 2960 and a document in which make reference to a BUG in which mention about arp overwrite due arp attack which produce DoS.
Trying to set-up a p2p link between a L2 fast ethenet module (within a 2900) to a 6506.Have created a subinterface SVI on the 2900 and put the fast ethernet port in the respective VLAN. However on 6506, am I correct in thinking I can do a no switchport and just create a L3 interface? Do I need to put the 6506 in the same vlan and the fast ethernet module and create a L3 SVI on it? As it's not a trunk port between the 6506 and the fastethernet module, the packets won't be tagged?
I am having issues (nothing new there) I have a bad IOS on a switch module, and the config is set to boot to that IOS, and as such I get a nasty boot loop, I am trying to figure out how to get into rommon but all the documentation I can find for this just says go into rommon and never tells me how to get there on a switch module that thinks it has a good IOS. (The IOS is for our normal service module but this one is an odd-ball switch)
Does the Network Module "C3KX-NM-1G" and "C3KX-NM-10G" for Cisco Catalyst Switch 3750X Comes with a transciever like GLC-SX-MM or SFP-10G-SR or do I need to order in seperately.
Suffered a big outage on the network, the fix was to reload the module 3 on the 6509 switch, we had these errors on the log %CONST_DIAG-SW1_SP-3-HM_PORT_TEST_FAIL: Switch 1 Module 3 TestUnusedPortLoopback Port(s)[24,46] failed. System operation continues.in the end, we reloaded the card and it was all ok. is there anything I can do to check the card / or any deeper logs? would that error cause the card to crash?
I'm trying to set up a 2951 with a 24 port switch module. I want the ports to act similiarly to the ports on an 881 router - where I assign the VLANs on the router and I set the VLANs to the switchport interfaces.I would like to be able to create the VLANs on the router portion of the 2951 and then, enter the switch module and configure the Ports to the VLANs but, how do I logically connect router to the switch? Is it an internal logical interface - meaning how are the VLANs getting from the router to the switch?
i have configure new ACE 30 module on top of 6500 core switch , the issues am facing whenver i want to access to https://ACE_IP and after i enter the user name and the password , it's forwared me to the follwoing page: is there anything should i configure to avoid this page ?
We got a new Cisco 2911 router (CISCO2911/K9) with a switch module (SM ES2-16-P) on it. Everything works fine after the configuration except for the power. We got 4 WAP that we will connect to the switch module that needs power. So the switch module with POE doesn't give any power out.
We have supplied Cisco Swtch 2960 with gig SFP modules. It is working fine. However, when I do a show inventory it show proper part no. for the switch chassis but for the GLC T module it shows as unspecified in the PID column.
I have a problem with a newly bought ws-x4548-rj45v+ i've plugged in the module but when i do show modules all , it show as unsupport
Power consumed by backplane : 0 Watts Mod Ports Card Type Model Serial No.---+-----+--------------------------------------+------------------+-----------1 2 Supervisor IV 1000BaseX (GBIC) WS-X4515 JAE1048GAXQ2 48 10/100/1000BaseT (RJ45) WS-X4448-GB-RJ45 JAB064806WN3 48 10/100/1000BaseT (RJ45) WS-X4448-GB-RJ45 JAB063005DB4 0 Unsupported module WS-X4548-RJ45V+ JAE1545056U M MAC addresses Hw Fw Sw Status--+--------------------------------+---+------------+----------------+---------1 0007.0e64.f880 to 0007.0e64.f881 5.2 12.2(20r)EW1 12.2(46)SG Ok2 000b.5fa4.da20 to 000b.5fa4.da4f 1.0 Ok3 0009.e844.d760 to 0009.e844.d78f 1.0 Ok4 ccef.4815.9bf0 to ccef.4815.9c1f 2.0 Unsupport
My questions is can a 4 port PoE switch module (EHWIC-4ESG-P) and a 8 port switch module (EHWIC-D-8ESG) be used at the same time in a Cisco 1941 router?
I have a laptop with a single physical NIC which I have used the advanced management tools to create two virtual NICs (say vlan 10 and vlan 20) and both are on the same subnet (say 192.168.4.x). One NIC is for normal TCP/IP traffic and one is for broadcast/multicast traffic (I have some custom software that requires this to be the case and works fine on an older laptops with built-in physical NIC and PCMCIA XIRCOM NIC). The dual NIC laptop communicates with a dual NIC server via a Cisco 2811 router (which has a 16 port switch module at the back) and has vlans set up so.
What I want is for the single NIC laptop (with two virtual NICs) to be able to also communicate with the server. Basically, one NIC is for normal traffic and one is for multicast/broadcast traffic. All three machines need to be able to talk to each other using the NIC for normal traffic and both laptops must be able to receive broadcasts from the server. What is the best way to configure the router to handle the trunking/tagging? Most configuration documentation I read has two complete subnets for the two virtual NICs. Note that all three machines use static IPs and are part of a workgroup so no DNS and domain servers etc.
Trying to find some documentation as to whether there are any other steps for inserting this new module in our N7K. We have 2 blades in already and 2 Sups in 5 & 6. I'm assuming its like the 6500s, where we just slide it in and the OS configures the global parms for it and the default VLAN.
We having a VSS switch (9 slot chasis) with ios "s72033_rp-ADVENTERPRISEK9_WAN-M), Version 12.2(33)SXI4", slot 7-9 are currently free. We wanted to install WS-X6708-10G-3C module on slot 7. Once we installed the module it didnt come, after waiting for 15-20min again we removed and inserted, but module didnt come up and we could see following logs on the console:
Jan 12 08:57:40.146: %ISSU-SW2_CFC2-3-ERP_AGENT_SEND_MSG: client/entity send failed; error code is timeout *Jan 12 08:57:40.330: %ISSU-SW2_SPSTBY-3-ERP_AGENT_SEND_MSG: client/entity send failed; error code is timeout Jan 12 08:57:40.146: %ISSU_ERROR-SW2_CFC2-3-START_NEGO_FAILED: ISSU NTI Client(2040): failed to start negotiation (ISSU_RC_CLIENT_ENTITY_DOES_NOT_EXIST_IN_PEER)
[code]....
Afer some time VSS switch didnt response to console commands and all the users in access switches were not able to reach the gateway (VSS). Then the problem disappeared once we rebooted both the switches in VSS.why the VSS switch become non-responsive?
can i use any downlink port of the C4500-X switch as uplink without the need of the network module?i need to connect that switch to C6500E backbone without getting the network module, is that OK or i must get the network module?
how this switch module works in 2911 router? I have two 2911 routers in HSRP configuration for redundancy with crossover cable between switch modules. OSPF running on routers.If active router loses its power and then comes back again, it boots first, its internal link to switch module comes up and it starts to forward packets to switch module. The switch module starts to boot only after router is ready. So I have outage of about 3-4 minutes. For our real-time applications it is way too long.
any way to start booting of the switch module before router gets ready?I understand I can boot it manually, but it is only after router is ready. Only way to get around it I found is to disable internal link and use router interface to connect to the switch module.
I am trying to research the possiblity of backing up IOS and configurations from an Etherswitch module, and being able to store the files onto the Host Router's flash (3925 ISR). and then being able to recover that IOS and configuration, in case I have to replace the Etherswitch Module.
After a power problem at our data centre we find Module 11 of our Cisco 6513 Core Switch in PWR Down state.Show Module 11 returns: Status: PWRDownShow Power Status Module 11 returns: OperStatus Off (Module Reset due to an exception or user request).The command: Power enable Module 11 was issued and returned the following: %PM_SCP-SP-1-LCP_FW_ERR: System resetting module 11 to recover from error: Linecard received system exception. Errcode = 2509000001.%OIR-SP-3-PWRCYCLE: Card in module 11 is being powercycled Öff (Module reset due to exception or user request%C6KPWR-SP-4-DISABLED: Power to module in slot 11 set off (Module Reset due to exception or user request),We have restarted the switch twice. The module is currently not passing traffic causing downtime to services.
switch catalyst 4500 with ios cat4500e-universal.SPA.03.02.00.XO.150-2.XO.bin. I need to configure modules 3 and 4 of supervision, the problem is that I need the 4-port module 3 are active but only the first turn on both the module 3 and the first port on the module 4. [code]
I have a 3925 Router with a 48 port switch module (part number SM-D-ES3G-48-P). I have no problem accessing the 3925 Router, but when I go into the 48 port, I get an error that reads
Error Hardware not supported by firmware. Try loading a newer software instead. System Resetting...
I know that the wrong IOS is installed on the switch, but the problem is that this is an endless loop. The switch resets then comes back to the same error. How to get the switch out of this loop so that I can load the correct IOS.