After launching config collection job in LMS 4.2 I can't get job results and receive error message - Unable to get results of job execution for device. I've increased the job result wait time using option in Admin > Collection Settings ... , but nothing changed.Here are screenshots of error message and wait settings I used.
I'm having an issue with LMS 4 where it's failing to collection configuration from devices.
The following is the status of your Scheduled Config collection job:
Job ID : 1045 Status : Job Failed(111) Description : System config collection job
[Code]....
I researched through this forum and found a thread where the ConfigMgmtServer server wouldn't run. Looking at the processes it says that this service is running normally.
i have an issue with the lms 4.2 Topology Data Collection. After installation the Topology Data Collection was running normaly, but since first server reload the Topo Data Collect under Inventory > Dashboards > Device Status > Collection Summary is "frozen".Is there any option to stop this process elsewhere? I cannot find anything under jobs in running state or so. Clicking on Schedule only give me the option to start data collection, but lms always returns that the process is running.
After I upgrading all device packages, inventory collection failure to complete. All devices stuck on pending state and at the end of the job all devices are under not attempted and job result description ses " Timed out. Make shure that ICServer is running". I made sure that ICServer is running.
I have Cisco Works LMS 4.0 on Win 2K8 64 bits on VMware EXs. I am facing issue with reference to Inventory Collection, my 10% devices (including Routers & Switches) Inventory collection is failed and give me error (Device sensed, but collection failed). I increase the SNMP timeout 10 sec, 30 sec, 60 sec and even 100 sec the result be the same.
I have a problem with the User Tracking and Data Collection on LMS 4.0.1 . I think It crashes every time or freezes. I Have this error if I lunch UT Acquisition :
Failed to start acquisition: Construction of XML data required for UT IS in progress. Please try After Some Time.When scheduling a CM data collection, I have this error: Data collection IS Already in progress.
I detected an error in ani.log line 12266: Exception in thread "Discovery" java.lang.AbstractMethodError: com. cisco. nm. ani. server. topo. Port Channel.portIfIndex ()
I successfully changed the name of the CiscoWorks server last week with the tool hostnamechange.pl.
A customer of mine have 2 VSS systems for wich IC times out during collection when trying to read from flash on them. From the ICserver.log
[ Thu Dec 13 16:45:19 CET 2012 ],WARN ,[Thread-20],com.cisco.nm.rmeng.util.logger.XDILogger,67,com.cisco.nm.xms.xdi.pkgs.SharedInventoryCatIOS.FlashAGI_CISCO_FLASH_Mib,g$eval,70,com.cisco.nm.xms.xdi.pkgs.S
LMS 4.0.1 installed on Windows Server 2008 R2 Standard with SP1. Created Inventory collection job, but couple of hours later, it is failed with all devices Not Attempted. Increased SNMP timeout on 10 sec, started again for only 1 device - collection failed again. I am attaching pdshow and ICServer file.
we have installed LMS 3.2 when i try to run data collection it shows "Notified server to run campus data collection", but status of data collection is idle.
If i restart the server and try to run data collection it runs properly one time.
Each time i have to restart the server for data collection.
We have LMS4.0 monitoring 100+ devices. In that collection we have 2 4506e switches. The switches are identical,but one is inventoried successfully and the other always fails.Both have verified their credentials. The 4506e failing inventory is the only device not being inventoried.I looked at other post and increased snmp timeout with no effect.
Does two separate SCE 2000 devices can share a collection manager, or do they each need a separate CM? If they can share, is there any special setup on the CM itself?
The problem is that the syslog collection suddently stops receiving logs and writing them into the syslog.log file
I have checked the following:
- Packet sniff to make sure that logs are being received on the server's NIC interface - Checked the UDP port 514 is bound to the crmlog process. - Checked the crmlog is running.
When i restart the server, the syslog connections works for a week or two and save the received logs in the syslog.log file, but after that it suddenly stops collecting log again, all the above points stays valid (service running, UDP Port...)
I have attached the LMS's modules versions installed on the server.
Usually the configuration files are fetched once every week. Lately, the Scheduled Config collection job is failing for all the devices. I have tried to “sync Archive” from LMS 3.2 on some devices but nothing happens. The switches out there are C3750, 2960, 2950, 3550, 3650 and some routers.The server is Win Ser 2003.
I reinstalled CiscoWorks LMS (Windows 2008 R2) updated th LMS with all availible devicepackages and imported all devices with a xml bulk import of the former installation. Now I am frustrated.... because after the reinstallation LMS has problems collecting the inventory data.The inventory collection for one local device (Cisco WS-C3560-8PC-S) starts and nevers stops.... I have to stop the ICserver to stop the inventory collection.
I have only 4 of nearly 1800 devices where it was possible to collect the inventory information.All the rest is supposed to unreacheable...Reports> Inventory>Management Status>Unreachable Devices.But if I take one of the devices which is reported to be unreacheable and do a device diagnostic (Monitor> Troubleshooting Tools> Troubleshooting Workflows) says it is reacheable...
The inventory does not appear in the "Collector Status"?
Data collection runs forever (since this morning). Also an reboot of the LMS server didnt work. Checked all processes and ani.log -OK. After reboot, the time stemp for Toplogy changed from 8:00 to "Not Available"
Inventory Collection24019 Apr 2012, 12:15 CEST IdleScheduleConfig Archive24016 Apr 2012, 16:24 CEST IdleSchedule
i have all of my music/ films on PC running windows 7 (might upgrade to 8) i would like to be able to browse my collection on a tablet (using it as a remote) and be able to play it through my stereo / tv. i would like this done with as few wires as possible none would be best im guessing i will need some from the pc to the stereo and tv
On our CiscoWorks 2000 installation, running on Solaris with LMS3.2 and RME4.3.1, we noticed a few weeks ago, that the job "Inventory Collection" needs more and more time to finish. At the moment the job execution time is as high as 8 hours, compared to 3 hours before. When we look at the network traffic during job execution, we see after the collection phase (~3h) several hours with no traffic together with a very high CPU load. I mean to remember that this job used to complete around 15 minutes after data collection phase. Restarting the application and rebooting the system didn't work.When we look in to the IC_Server.log, we find devices with a completion time of over 20'000 seconds. Increasing from day to day. [code]
Affected devices are Cisco Nexus 5548P. We tried to delete/add these devices. That works for a few days, then the runtime starts to increase again.
Are we hitting a bug? And is it possible, as a workaround, to exclude devices from only the Inventory Collection?
I have an LMS 3.2.1 server running user tracking collection starting at 11:30am. We also use InterMapper to monitor switches. Right around the time UT collection is running, InterMapper starts to alert about "No SNMPv2c response".
When I do an Inventory Collection, the job doesn´t work with some devices and I have to restart the server. The job doesn´t fail but the log ICServer.log doesn´t got any information and it works for hours and hours and when it finally stops I can see that devices are not attempted.
I have done some succesfull Inventory Collections with Cisco 3750 switches and 805 routes. I have tried witch Cisco 2811 routers and 2950 and 2960 switches but it doesn´t work.
I have tried to update my LMS4.0.1 but it doesn´t find any actualization. However, in the Cisco download page there are some patches.
I have 3560-24PS-S (ios version 12.2(35)SE1) that have high CPU (almost 100%) use at every inventory collection (each sunday) or polling (each day 6 a.m) during 2 or 3 minutes.
I read on the forum, that this could be due to some mib object polling failure, and could, perhaps, be solved by upgrading the ios version or configuring view preventing the poll of the problematic object.
But what view to configure ?Is there well known MIB objects to filter ? Which ones ? I did not see any bug related to my IOS version and this behavior in the bug toolkit ... I join some sh commands (unfortunately done when no problem). I will try to obtain the output of the sh command when the pb occurs.
2 Nexus 5020 (SysObjId 3.719) brings internal error in inventory collection as following:"RICS0001: Internal Error, unable to process the collected data from the device".whereby 2 other devices from same type, same sysobjid are working well. SDT from v401 shows this device as supported.
1. When creating job or log file, these files are always stored in the default Path (inside LMSROOT) for RME for example...Could I change RME default Path to store these files in another location inside the Hard Disk?
2. Could I Configure CW-LMS to send all the reports to me by mail?
3. What is the Difference between Poll Interval time and Collection time inside RME?
I have larger numbers of WS-C3560X-24/24P/48 Cisco switches with1000BaseSX SFP GIBCs installed per switch in my network and they are all added to my DCR just fine. However, when i generate an inventory hardware report GBICs and GBICs serial number is not showing up. Is there any special settings i need to make?
I am position to migrate from CatOS 6509 switch to native IOS 6509 switch. long time ago, there was some site to convert automatically based on copy and paste onto the tool, but i can not find.
Does anybody know how to convert CatOS configuration to Native IOS configuration ? It is not IOS change, but it is configuration convert.
I have webcams that need port 8081 opened and I did that, everything worked fine until my DIR655 jammed up and power cycling it and the modem 3-4 times DID not make it work: no internet access and it was definitely a DIR655 problem. So, out with the paperclip to do the big reset, causing me to lose my configuration. When "most" of it came back up with my new config (I had screen prints), all was okay EXCEPT the webcams. Addresses and ports were all configured properly, address was fixed too on the client computer rather than use DHCP. I had a DNS relocation service running (DYNDNS) for the WAN side, but that address (My IP) didn't change either. I tried EVERYTHING. Finally, I realized in all my screwing around that I had enabled UPnP in my application, something I hadn't done before, but did this time as a desperation move. UPnP had always been checked off in the router. So.....I REMOVED my port forwarding and virtual server settings (either one worked before), and voila, everything working, Is this a normal occurrence, that if you have UPnP running, that this auto configuration overrides any manual configuration?