I have CiscoWorks 3.1.
1. When creating job or log file, these files are always stored in the default Path (inside LMSROOT) for RME for example...Could I change RME default Path to store these files in another location inside the Hard Disk?
2. Could I Configure CW-LMS to send all the reports to me by mail?
3. What is the Difference between Poll Interval time and Collection time inside RME?
after a certain period of time (ranging from 2 minutes to several hours) the unit keeps dropping the WAN connection, making the unit unaccessible from the WAN side. The strange thing is, that when the connection is dropped, the unit is perfectly accessible from the LAN side, the WAN LED is still on, status info shows the WAN link up, and packet trace shows broadcasted traffic on the WAN interface, so only the directed communication to and from the ISPs gateway (configured to fix IP) seems to be blocked for some reason. When this happens, then plugging the WAN cable to the Optional WAN port enables traffic again, but it is also dropped after some time, and then only power cycling the unit restores WAN connectivity.
Is there anyway to force the xbox inside the router to grab the same ip address everytime it comes on? Other than changing it on the console via a static ip? Xboxs dont like static Ip address and its getting annoying?
i am searching for the right SNMP-OID to poll the values of the CPU-load from a VSS (6509E)here a OID for VSS-Switch1 and a other OID for VSS-Switch2 values like cli-command "sh proc cpu" of the supervisor-module in slot 5.
I have two Nexus 7010 in the data center. I'm unable to poll SNMP data from one of the NEXUS 7010s. The other Nexus 7010 is working fine. I have compared the SNMP configurations, and they are identical. When I do "show snmp" on the non-working switch, I have SNMP packets in "Unknown Context name", not sure why. I have done show vdc and it matches the working switch output. Here is output of show snmp from the non-working switch: 133 SNMP packets input 0 Bad SNMP versions 0 Unknown community name 0 Illegal operation for community name supplied 0 Encoding errors 0 Number of requested variables 0 Number of altered variables 0 Get-request PDUs 0 Get-next PDUs 0 Set-request PDUs 0 No such name PDU 0 Bad value PDU 0 Read Only PDU 0 General errors 0 Get Responses 133 Unknown Context name0 SNMP packets output 0 Trap PDU 0 Too big errors 0 No such name errors 0 Bad values errors 0 General errors 0 Get Requests 0 Get Next Requests 0 Set Requests 0 Get Responses 0 Silent drops.
A customer has a wireless PTP bridge using a pair of 1410 bridges. The non-root bridge event log shows the RSSI polling information message indicating the link's signal strength; ie. -42 dBm. It updates every few seconds or so. The root bridge does not show this information in the event log. Both bridges have the event log configuration options set identically, all messages types are enabled. I can't find any reference to this in the documents. Is this by design? I thought that maybe a root bridge if it was set up as a multi-point might be overwhelmed if it was showing/scrolling RSSI from multiple non-roots.
I have a cisco 7600. It will send an icmp request every second. If the icmp response is not received, 3 consecutive icmp requests will be sent. SLA reachability down will be reported after all 4 icmp responses are not received. The following diagram illustrates my goal.
Sender --------------------------------------- 0 second -> 0 sec (1st icmp Request is sent out)-> 50ms (no response, send 2nd icmp after timeout)-> 50ms (no response, send 3rd icmp after timeout) -> 50ms (no response, send 4th icmp after timeout) 50ms Report SLA reachability down --------------------------------------- 1 second --------------------------------------- 2 second
Question: will the following configuration achieve my goal?
ip sla 100icmp-echo 10.32.24.1 source-ip 10.32.24.2timeout 50frequency 1
The various setup pages of the RV220W router have an auto-refresh interval. I can change the interval from the default 10 seconds to 60 seconds maximum.I cannot change the Dashboard to different than 10 seconds.Every time I try to work with these pages, they black out and refresh, stopping my work.How do I change the Dashboard auto refresh interval to 60 seconds?Can I change all the auto refresh intervals to 10 minutes?
I have 2 questions.Om my cisco 2811 (IOS 12.4(15) T9 IPBASE W/O Crypto) i am using 3 interfaces.And i have a pool of Global addresses: 200.x.z.97-200.x.z.126 255.255.255.0
FastEthernet 0/1 description WAN interfaceip nat outsideip address 200.x.y.253 255.255.255.0
I'm trying to configure hairpinning on my Cisco 887VA VDSL router, so all LAN users can connect to the server using SMTP port 25 which is also in the same LAN subnet, using external router address, which is assigned to dialer1 interface.Traffic comming in from outside works fine.
External IP: 1.1.1.1/29 PC address connecting to the server: 192.168.101.28 Server address: 192.168.101.200 IOS: 15.1.4M1
[code]....
I'm running tcpdump on the server on port 25 and... nothing happens. The traffic is not going through.One thing that I've notices in debug ip packet is this line:
s=1.1.1.1 (Vlan1), d=192.168.101.200 (Vlan1), len 52, rcvd local pkt
shouldn't source be internal vlan1 IP - 192.168.101.1?
After launching config collection job in LMS 4.2 I can't get job results and receive error message - Unable to get results of job execution for device. I've increased the job result wait time using option in Admin > Collection Settings ... , but nothing changed.Here are screenshots of error message and wait settings I used.
i have an issue with the lms 4.2 Topology Data Collection. After installation the Topology Data Collection was running normaly, but since first server reload the Topo Data Collect under Inventory > Dashboards > Device Status > Collection Summary is "frozen".Is there any option to stop this process elsewhere? I cannot find anything under jobs in running state or so. Clicking on Schedule only give me the option to start data collection, but lms always returns that the process is running.
After I upgrading all device packages, inventory collection failure to complete. All devices stuck on pending state and at the end of the job all devices are under not attempted and job result description ses " Timed out. Make shure that ICServer is running". I made sure that ICServer is running.
I have Cisco Works LMS 4.0 on Win 2K8 64 bits on VMware EXs. I am facing issue with reference to Inventory Collection, my 10% devices (including Routers & Switches) Inventory collection is failed and give me error (Device sensed, but collection failed). I increase the SNMP timeout 10 sec, 30 sec, 60 sec and even 100 sec the result be the same.
I have a problem with the User Tracking and Data Collection on LMS 4.0.1 . I think It crashes every time or freezes. I Have this error if I lunch UT Acquisition :
Failed to start acquisition: Construction of XML data required for UT IS in progress. Please try After Some Time.When scheduling a CM data collection, I have this error: Data collection IS Already in progress.
I detected an error in ani.log line 12266: Exception in thread "Discovery" java.lang.AbstractMethodError: com. cisco. nm. ani. server. topo. Port Channel.portIfIndex ()
I successfully changed the name of the CiscoWorks server last week with the tool hostnamechange.pl.
A customer of mine have 2 VSS systems for wich IC times out during collection when trying to read from flash on them. From the ICserver.log
[ Thu Dec 13 16:45:19 CET 2012 ],WARN ,[Thread-20],com.cisco.nm.rmeng.util.logger.XDILogger,67,com.cisco.nm.xms.xdi.pkgs.SharedInventoryCatIOS.FlashAGI_CISCO_FLASH_Mib,g$eval,70,com.cisco.nm.xms.xdi.pkgs.S
I'm having an issue with LMS 4 where it's failing to collection configuration from devices.
The following is the status of your Scheduled Config collection job:
Job ID : 1045 Status : Job Failed(111) Description : System config collection job
[Code]....
I researched through this forum and found a thread where the ConfigMgmtServer server wouldn't run. Looking at the processes it says that this service is running normally.
LMS 4.0.1 installed on Windows Server 2008 R2 Standard with SP1. Created Inventory collection job, but couple of hours later, it is failed with all devices Not Attempted. Increased SNMP timeout on 10 sec, started again for only 1 device - collection failed again. I am attaching pdshow and ICServer file.
we have installed LMS 3.2 when i try to run data collection it shows "Notified server to run campus data collection", but status of data collection is idle.
If i restart the server and try to run data collection it runs properly one time.
Each time i have to restart the server for data collection.
We have LMS4.0 monitoring 100+ devices. In that collection we have 2 4506e switches. The switches are identical,but one is inventoried successfully and the other always fails.Both have verified their credentials. The 4506e failing inventory is the only device not being inventoried.I looked at other post and increased snmp timeout with no effect.
Does two separate SCE 2000 devices can share a collection manager, or do they each need a separate CM? If they can share, is there any special setup on the CM itself?
The problem is that the syslog collection suddently stops receiving logs and writing them into the syslog.log file
I have checked the following:
- Packet sniff to make sure that logs are being received on the server's NIC interface - Checked the UDP port 514 is bound to the crmlog process. - Checked the crmlog is running.
When i restart the server, the syslog connections works for a week or two and save the received logs in the syslog.log file, but after that it suddenly stops collecting log again, all the above points stays valid (service running, UDP Port...)
I have attached the LMS's modules versions installed on the server.
Usually the configuration files are fetched once every week. Lately, the Scheduled Config collection job is failing for all the devices. I have tried to “sync Archive” from LMS 3.2 on some devices but nothing happens. The switches out there are C3750, 2960, 2950, 3550, 3650 and some routers.The server is Win Ser 2003.
I reinstalled CiscoWorks LMS (Windows 2008 R2) updated th LMS with all availible devicepackages and imported all devices with a xml bulk import of the former installation. Now I am frustrated.... because after the reinstallation LMS has problems collecting the inventory data.The inventory collection for one local device (Cisco WS-C3560-8PC-S) starts and nevers stops.... I have to stop the ICserver to stop the inventory collection.
I have only 4 of nearly 1800 devices where it was possible to collect the inventory information.All the rest is supposed to unreacheable...Reports> Inventory>Management Status>Unreachable Devices.But if I take one of the devices which is reported to be unreacheable and do a device diagnostic (Monitor> Troubleshooting Tools> Troubleshooting Workflows) says it is reacheable...
The inventory does not appear in the "Collector Status"?
Data collection runs forever (since this morning). Also an reboot of the LMS server didnt work. Checked all processes and ani.log -OK. After reboot, the time stemp for Toplogy changed from 8:00 to "Not Available"
Inventory Collection24019 Apr 2012, 12:15 CEST IdleScheduleConfig Archive24016 Apr 2012, 16:24 CEST IdleSchedule
i have all of my music/ films on PC running windows 7 (might upgrade to 8) i would like to be able to browse my collection on a tablet (using it as a remote) and be able to play it through my stereo / tv. i would like this done with as few wires as possible none would be best im guessing i will need some from the pc to the stereo and tv
On our CiscoWorks 2000 installation, running on Solaris with LMS3.2 and RME4.3.1, we noticed a few weeks ago, that the job "Inventory Collection" needs more and more time to finish. At the moment the job execution time is as high as 8 hours, compared to 3 hours before. When we look at the network traffic during job execution, we see after the collection phase (~3h) several hours with no traffic together with a very high CPU load. I mean to remember that this job used to complete around 15 minutes after data collection phase. Restarting the application and rebooting the system didn't work.When we look in to the IC_Server.log, we find devices with a completion time of over 20'000 seconds. Increasing from day to day. [code]
Affected devices are Cisco Nexus 5548P. We tried to delete/add these devices. That works for a few days, then the runtime starts to increase again.
Are we hitting a bug? And is it possible, as a workaround, to exclude devices from only the Inventory Collection?