Cisco Switching/Routing :: WS-C4506-E / Module Status And Diagnostic Result Analysis
Mar 24, 2013
I installed WS-C4506-E 3 day ago. I discovered someting different module status Right at the end of the module ( WS-X4648-RJ45-E ) show red led. this is not port led i try to reset module several time. but it's same status. but this is operating now nomally I upload picture.. and this is module status and diagnostic result
Error code ------------------> 3 (DIAG_SKIPPED)
This Case is DOA(Dead of arrival ?
C4506#sh modChassis Type : WS-C4506-E
Power consumed by backplane : 0 Watts
Mod Ports Card Type Model Serial No.---+-----+--------------------------------------+------------------+-----------1 6 Sup 7L-E 10GE (SFP+), 1000BaseX (SFP) WS-X45-SUP7L-E ABCDE1234562 24 1000BaseX (SFP) WS-X4624-SFP-E ABCDE123456 6 48 10/100/1000BaseT (RJ45) WS-X4648-RJ45-E ABCDE123456
M MAC addresses Hw Fw Sw Status--+--------------------------------+---+------------+----------------+---------1 b0fa.ebe5.16c0 to b0fa.ebe5.16c5 1.1 15.0(1r)SG3 03.03.00.SG Ok 2 b0fa.ebc6.5b70 to b0fa.ebc6.5b87 1.2 Ok 6 10f3.1197.1490 to 10f3.1197.14bf 2.1 Ok
One of our Nexus 7000 modules failed and generated the status below. Could this possibly be a hardware issue?
# show module Mod Ports Module-Type Model Status --- ----- ----------------------------------- ------------------ ---------- 1 0 10 Gbps Ethernet XL Module powered-dn Mod Power-Status Reason --- ------------ --------------------------- 1 powered-dn Unable to power up card (Power_OK not set)
We have two 6509 switches with one WS-X6704-10GE module in each of them. There is an optical cable between the two switches plugged in WS-X6704-10GE module on both sides. When you shut down the port on one side the other port still stays as up and you need phisycally to unplug the cable to have it down. The same behaviour is seen no matter on which of the two switches you shut down the port, the opposite one always stays as up and only removal of the cable makes it go down.
The ports are configured quite simply:
interface TenGigabitEthernet1/1 switchport switchport trunk encapsulation dot1q switchport trunk allowed vlan 1-10 no ip address udld port
documentation on upgrading a WS-SVC-NAM-2-250S. I am looking to upgrade to 5-1-2 code if possible. I am only finding documentation for Prime version 3 NAM not version 2 that runs with 6500-SUP-720.
just found that on [URL], it stated that Cisco ASR 1000's management tool is Cisco Prime Network Analysis Module, which is same name as software that can be install in SRE of Cisco ISR G2 router for network analysis via web browser.
My question here is this mean Cisco ASR 1000 has built-in support for Cisco Prime Network Analysis Module, which has similar function as the one on Cisco ISR G2 router's SRE?
We are facing problem with Cisco IP phones which are connected to module WS-X4248-RJ45V.Phones are getting restarted and sometimes phones will not take power.Initially we suspected issue with power consumption, but we have enough power in the module.
I have two C4506 switches and I would like to create two L3 links between them by using only one physical link. I will then assign each L3 link to a different VRF.
I think I have two choices but I'm not sure however that the second one is possible...
--------------- 1st choice: creating two VLANs and two SVIs on each switch
interface Vlan10 ip address 10.10.10.1 255.255.255.252 ip vrf forwarding vrf1
interface Vlan20 ip address 10.10.10.5 255.255.255..252 ip vrf forwarding vrf2(code)
System returned to ROM by reloadSystem restarted at 00:36:52 UTC Sat Dec 10 2011System image file is "bootflash:cat4000-i9s-mz.122-25.EWA14.bin" cisco WS-C4506 (MPC8245) processor (revision 10) with 262144K bytes of memory.MPC8245 CPU at 266Mhz, Supervisor II+Last reset from Reload1 Virtual Ethernet interface144 FastEthernet interfaces2 Gigabit Ethernet interfaces511K bytes of non-volatile configuration memory.Configuration register is 0x2102
I am not getting interface up/down logs in my switch console through show logging command. Switch model cisco WS-C4506-E and IOS :- cat4500e-ipbasek9-mz.122-53.SG3.bin. I have done below mention configurations, we can't configure logging level beyond informational. [code]
Switch automatically restarts for no reason , I have upgraded the software.can not find fault. more crashinfo, see the following output:
HKZ-SSL-4-NAN-4506#more crashinfo:data Current Time: 5/27/2013 10:28:10 Last Power Failure: 05/08/2013 16:55:28 Last Reload Status: 00000000 Last Software Reset State: 00000301
We just replaced our Cisco 1240 AP in one of our shops with a Cisco 1141 AP. This is not controller based.
We use several wireless (infrastructure mode) auto diagnostic tools which connect to the AP. We also have many laptops which run the diagnostic software.
We had no problems with our 1240AP. With our 1141, we cannot connect to the wireless tools if both the laptop and the tools are connected to the 1141. If I connect one to the 1240 and one to the 1141, they can see each other and work fine. IF they are both connected to the 1141, they show up as connected in the AP, they can ping each other, but the software does not communicate.
The following error was seen on the switch and the Diagnostic Test Loop back failed following a new WS-6748-SFP module installation.Fabric in slot 5 detected excessive flow-control on channel 3 (Module 4, fabric connection 1)
Tried Hard reset of the module and still the error persist.
We just recently purchased a 3945 ISR G2 router and have a SRE-910 module (with two hard drives) configured in a Raid 1. We are running a stand-alone version of ESXi on the service module and I'm trying to figure out how to monitor the status of the Raid on the drives (along with other health issues). SNMP has revealed nothing so far and even opening a support case for which MIB's to use has proved fruitless. All the documents I find on monitoring the modules say to use LMS which is now Cisco Prime. I've downloaded the trial copy, put in the SNMP settings and scanned the router. I get device results and it shows that I have the SRE-910 module installed, but I get no other configuration / device informaiton from the module itself.
I tried to create a new Monitoring template using the NAM health as the base template (which I'm assuming this is the correct template). Unfortunately, when I actually try to deploy the template against the discovered router, I get an 'Unexpected end of list' error which makes me assume I'm still doing something wrong.
After inserting a RSP720-3C-10GE in module 6 and running the show module command display the following [code]what is the meaning of the UnKnown on the oline diag status ?
The problem is WiSM module not coming in OPER-UP status , it’s in Started-Keepalive status.I did run debug wism events on cat6509 and seeing below logs:
[code]...
It’s receiving garp request from controller and assign ip to controller but then keepalive time expired and it’s put the controller in started-keeplaive status.
We recently connected a RPS 2300 to our switch WS-C3750G-48PS-E with IOS c3750-ipservicesk9-mz.122-53.SE2.bin.However i do not see any RPS details in the"show env" output.I believe i should get the RPS Name and its Serial and the port number in the output, but i am not finding it in the output. I did reload the switch but still couldnot get this udpated.
We had to transport one of our 4948 10 GE to another Data Centre and when we got it there and tried to power up its System Status LED was red and we cannot even get console to the device.
We can try to see if the switch is completely dead and needs replacing or is there something we can do to get it back up and running again?
I have recently installed 4 3560 (WS-C3560X-48T-S) Switches. At first the switch comes up, indicating all connected ports with a green LED. Whenever i unplug a cable and plug it back in, the status LED will stay off. The same thing happens when I push the mode button and cycle throgh the different modes, i lose certain LEDs.
I'm using 12.2(53)SE2, another user reported the same issues under 12.2(55)SE1 .
Below memory status alerts of are seen on our syslog server for Nexus 7K switch(Default VDC).
PLATFORM-2-MEMORY_ALERT_RECOVERED: Memory Status Alert : CRITICAL ALERT RECOVERED PLATFORM-2-MEMORY_ALERT_RECOVERED: Memory Status Alert : MINOR ALERT RECOVERED PLATFORM-2-MEMORY_ALERT_RECOVERED: Memory Status Alert : SEVERE ALERT RECOVERED
Memory threshold Not created on Nexus. Can we ignore this alert or does it impact our current network traffic?
I have installed and configured 2 new WS-3750E-24TD in the last 30 days, that have software version 12.5(50)SE2-universalk9, on our flat Development LAN (currently 7 existing WS-3750E-24TD with 12.5(35)SE2-universal)The new switches have shutdown, 1 has shutdown twice and I just had the other one shutdown on the weekend, all the status lights on the left are lit up but no port lights are on, I am not able to console in to the switch all I can do is cycle power. I am planning on upgrading all switches to the latest software release universalk9-mz.150-1SE
could this problem be a version incompatibillity between the switches?
In my 6513 switch chassis we have two Supervisor Engines 720 one is marked Active other as Hot. what is the diffrence in their mode as by name I suppose that Active one is currently in use and Hot one is in standby mode.They are showing in this manner.
I enabled the "no service password-recovery" command on my C2960 switch. All seems to work as discribed. Only issue I have is --- which show command is used to reveal if the password-recovery feature is enabled of disabled as the command doesn't show up in the running config after you enable it ?
NOTE: The command does show up in the C2960 switch in config t mode (unlike the IOS router 2800 series), but doesn't show up in the running-config after you enable or disable it.
On the 2800 series routers (latest IOS) in config t mode the command does not show up but if you type "no service passowrd-recovery" the command function correctly and it does list it in the running configuration.
On a 4500 switch having a single sup engine, another sup engine was installed to act as redundant one.the redundancy mode was changed to sso, thereafter the secondary sup was prompted to be reset.
After it came back up again, the redundancy status still shows as RPR in operation mode.
I have a really weired thing happening on 6509 device with one of my customers.The device has a SUP 2 (MSFC2) with version 12.2.18SXF17B.
any VLAN interface once administratively down or simply down shows on "show interface status" output as VLAN.While it supposed to show "Routed". However once the port is up it is shows "routed" like it should.
i have a cisco router (3900 series) and a add on module (4 x 1 Gig port module). For some reason i cant seem to port channel them and cant do routing (can set an ip address on those ports). I can do port channel and routing on on-board ports. Do i have to enable any commands to do this ?
Was wondering if anyone has ever hot ADDED, not swapped, an expansion module in a 5548up. Is a switch reboot required?I looked at the H/W install guide and it does not mention anything.
My C6506 USING ws-sup720-3B, i upgrade the IOS to the latest release of 12.2(33) SXJ1 IOS version. After upgrade and reload the machine got one module cannot be detect..WS-X6416-GE-MT, 16 port 1000mb MTRK ethernet module. The version of this are:
-HW 1.0 -FW 5.3 (1)1 -SW 8.5 (0.46) RFW
Question 1: Any tools available on cisco to check out the hardware/software compabiity feature?
Question 2: Any release note, compability matrix table etc resources.