Jan 20, 2013Is there a command that can be used to view what type of SFP module that is installed in Catalyst 3750 switch?
View 6 RepliesIs there a command that can be used to view what type of SFP module that is installed in Catalyst 3750 switch?
View 6 RepliesI am switching a switch connecting to the ASA5550 tomorrow. My current switch is using fiber connecting to the ASA. The new one only support copper. If I switch between fiber to copper on the ASA (change media-type command on interface) will it cause a down time? I have VPN tunnel on the ASA and don't want the session to reset.
View 2 Replies View RelatedI have Cisco Catalyst 2901 switch with Sup engine which have CatOS installed. I want to know that can I install Cisco IOS in this switch.
View 1 Replies View RelatedCould you provide me the main differences between SG500 and Catalyst 3750 command set?
View 2 Replies View Relatedswitch catalyst 4500 with ios cat4500e-universal.SPA.03.02.00.XO.150-2.XO.bin. I need to configure modules 3 and 4 of supervision, the problem is that I need the 4-port module 3 are active but only the first turn on both the module 3 and the first port on the module 4. [code]
View 1 Replies View RelatedWhat other command can be used to debug packets on a 3750 switch ?
View 2 Replies View RelatedWorking on my CCNA w/ live equip, I accidentley deleted the hardware IOS- yes, beginners mistake. Upon bootup, I do not get a command prompt. I tried the recovery procedure(hold mode button before power up) recommended by Cisco to no avail. My issue is I use SecureCRT & the charaters/font is ineligible. Here is an example of what I see when typing; "þæb Bûÿÿûýÿ¿¿ÿÿ". Currently, the SYST indicator is blinking & I have no access.
View 3 Replies View RelatedI have a Catalyst 3750 I want to add to an existing stack (same models) through the stackwise port We use some complex QoS and other features on our network, and I'm not sure how much configuration I need to do on the new switch before adding it to the stack. Since this is going into an existing setup?
View 9 Replies View RelatedI have a cisco 3750 swicth which i want to load a new ios to but unfortunately there's no enough space on the flash. This means that i need to backup the cureent (old) ios to my tftp server but the command keeps failing. It always gives 'No such file or directory' error .The free space on the flash is 8mb and my new ios is about 11mb.I also went inside the directory where the old is and inputed the same copy command but to no avail.Below are some of the command failure on the swicth:
[code]....
In my ongoing project i need to monitor cisco 3750-X port status (uplink/downlink) i.e. whenever there is some problem at a specific port. I need to monitor it through an OPC server and right now what i am doing is as follows: i am using Kepserver and i have added SNMP driver in it for that purpose i am not a networking expert but what i have learnt till now is that SNMP agent (that resides in switch) delivers the status of MIBs to SNMP manager ( which in my case is kepserver (opc server)) for the above purpose i am adding IF-MIB to monitor OID 1.3.6.1.2.1.2.2.1.8 (which shows port statuses) but when i add that in OPC server then it indicated that this OID is not available in the Switch ( it might be disabled) so i need to ask if there is any way to enable OID's in a switch,
View 0 Replies View RelatedI have got a new 48port Cisco catalyst 4948 switch, which I configured as a VTP client and connected to Cisco 3750 which is a VTP Server (this switch is on production network). I connected port g1/0/48 from 3750 to port g1/48 on 4948 through a straight cable and made both ports as trunk port (I also tried through cross cable). The problem is these two switches are not detecting. For testing I connected a PC directly to one of the port on 4948 (making that a switch port) still the LED on switch didn’t glow up. Is there any special command needs to be run on 4948 switches to activate its physical ports?
View 7 Replies View RelatedI have set up an ACL on my 3750 switch to deny icmp from PC A on our inside network to PC B on a different VLAN on our inside network using the following ACLs:
deny icmp host 10.1.17.15 host 10.3.10.4
deny icmp host 10.3.10.4 host 10.1.17.15
-- or --
deny icmp host 10.1.17.15 host 10.3.10.4 echo-replydeny icmp host 10.3.10.4 host 10.1.17.15 echo-reply
These ACLs belong to an access-list that also limits ip traffic to a few specific machines.When I try pinging from PC A I receive a reply message back from PC B. Shouldn't this configuration block any ICMP from PC A to PC B and from PC B to PC A? I would have expected the first ACL statement to block any packets associated with ICMP and when that didn't work I tried the second configuration.
On 3750 switch with IOS c3750-ipbasek9-mz.122-55.SE4.bin "eigrp stub static redistributed" command will be executable ?
View 1 Replies View RelatedI am trying to connect a SF200-48 switch via Mini-GBIC MGBLX1 fibre module to a Cisco 3750 switch with a GLC-SX-MM fibre module installed both running a 1000 Mbps. When connected together they do not enable. Are there compatibility restrictions or is it that the Mini-GBIC modules cannot be used to uplink to a LAN?
View 2 Replies View Related The Catalyst 3750 switch reboots, and the " Reloading because of stack merge or communication failure" error message appears.
I saw this issue at "Cisco wiki" but the resolution in that page is just "Open a case with TAC". Because of the reasion is H/W Problem.
Is The resolution only one ? anything else? The 3750 does not use Stack.It is just stand alone. So i think it has other resolution as "disabling Stack" or another one. How about my opinion ? Is the Resolution only "Open a Case with TAC"
One of my Catalyst 3750 switch have many out drops, I execute "sh mls qos int g2/0/3 statist" command, there are many output drops in queue3 threshold3. [code]
View 8 Replies View RelatedI want to limit the bandwidth of my Catalyst 3750 series switch, I read the cisco documentation and I applied the commands but I didn't get the wanted results.
For the outbound traffic it's ok, but for the inbound traffic I used policing but I get an unstable traffic. I used, an access list and a class-map to classify the traffic and then a policy-map.(I followed the steps mentioned in this site: [URL]
I have an office server set up to about 10 computers. We hired 4 new people and had to set up their computers on our network. Set up was easy and quick as usual. But when I was done, the other computer users, and even the new ones were complaining about not being able to access the DEFCON5 (name of our server) folder to get what they needed.
Basically the only workstations that show up when I click Network are the computers I added the other day, and the computer that is used more than any other computer (the CEO's). We can still access the files by typing the location as \DEFCON5****** and find what we need. But not everyone at my office is computer savy (no body is) and I would like to not have to keep running around and showing everyone this.
how many NM-32A or NM-16A module can be installed on 3745 and 3640 routers?
View 1 Replies View RelatedWe purchase a new 3945 router and a NM-1A-T3/E3 card. We would like to use the T3 funcationality so we enabled the command card type t3 1 (slot1), reboot the device.After reboot the sh ip int brief command should show the serial interfaces e.g serial1/0.In this case it doesn't, it shows the Gigi interfaces and ATM1/0 no serial interfaces.I've also tried upgrading to the latest IOS from cisco.
View 2 Replies View RelatedI found my CSC module installed in ASA 5510 unresponsive. I tried to recover / re-image the module with .bin file. but I think it is not possible to re-image because there is no rechability with CSC module, and session 1 command also doesn't work,
you can see the response here.
CS-ASA# session 1
Opening command session with slot 1.
Card in slot 1 did not respond to session request.
CS-ASA#
In this case how to enter into the module?
I removed and inserted the module and tried to reach to it .. but couldnt solve . I just wanted to know whether hardware is dead or not.
I have been looking into this for a while and I can't seem to figure out why my 2nd vlan is not able to connect properly to the net.
My switch has 12 ports where my devices connects directly, they are all on Vlan 1 and they all work perfectly. on Port 12 I have a dlink router that is connected to a cable modem. the dlink router has an Ip address of 192.168.0.20
I created a second vlan (vlan2) and enabled dhcp relay on it. then I assigned port 9 on the switch to (vlan2)my laptop which is connected to port 9 seems to get an ip address fine and able to ping only some devices on my network (vlan1) and is not able to go out to the internet. I think it has to do with the routes. [code]
I have been looking into this for a while and I can't seem to figure out why my 2nd vlan is not able to connect properly to the net. My switch has 12 ports where my devices connects directly, they are all on Vlan 1 and they all work perfectly. on Port 12 I have a dlink router that is connected to a cable modem. the dlink router has an Ip address of 192.168.0.20,I created a second vlan (vlan2) and enabled dhcp relay on it. then I assigned port 9 on the switch to (vlan2),my laptop which is connected to port 9 seems to get an ip address fine and able to ping only some devices on my network (vlan1) and is not able to,go out to the internet.
View 3 Replies View RelatedAny Cisco command similar to Junipers monitor interface interface type / number. It's handy seeing real time interface stats. monitor interface?
View 5 Replies View RelatedI am going to install new Nexus 7K. Installed SUP and one 32-Port 10Gb module. When I open the box to install this 10Gb module, I saw that there is a carbon paper is tighted with ***** on the top of the module. confirm either it will insert in Switch with carbon paper or have to remove this carbon paper?
View 1 Replies View RelatedLooking for a show command to display the actual physical Ram modules inside a 2911 router. I believe they come with 2x ram slots and I need to know if it has 1 ram stick or 2.show version displays the total amount of ram, but not if its 2x128 or 1x256 etc.This is also production gear so I cannot open it up and have a look until the scheduled downtime.
View 3 Replies View RelatedI have cat4500 with subject module. There is strange behaviour over module installed in 3rd slot only, some ports are connected, UP & working fine. But If I am connecting new ports over same module, are not coming UP.Duplex/speed settings already checked & are fine. If i connect same machine to any other module, it perfectly comes up & operation is fine.
View 3 Replies View RelatedWould like to check out is it possible binding Cisco secure ACS 5.x to support router/switch ios feature view - superview and parser command
Busines objective is assigning administrative roles, with different role based CLI access, using ACS5.X as backend server. a. Admin (allow all) b. network monitor (privlege # 7, enable view that can doing various show command and configure) c. support (privlege #1, read only)
We've got a doubt about the uplink ports of this supervisor. I've read that you have to use the four ports in 10G mode or in 1G mode, but not use for example 1 port in 10G mode and 1 port in 1G mode:
But, you can read in another sentence: " Beginning with Cisco IOS Release 12.2(25)SG, you could simultaneously deploy the dual 10-Gigabit.Ethernet ports and the four Gigabit Ethernet SFP ports on the Catalyst 4503, Catalyst 4506, and Catalyst 4507R chassis." Is it posible deploy simultaneously both type of ports?
I'm trying to upgrade an asr1001 (r1) from asr1001-universal.03.02.00.S.151-1.S.bin to asr1001-universalk9.03.02.00.S.151-1.S.bin. i've put in the boot system flash asr1001-universalk9.03.02.00.S.151-1.S.bin command and reloaded but the box keeps loading first image the configuration register is 0x2102. i've tried the license module command to enable adv enterprise but it made no difference so i removed it again. my license is now;
License Package Information for Module:'asr1001'
Module name Image level Priority Configured Valid license
asr1001 adv enterprise 1 NO adv enterprise adv ip services 2 NO adv ip services ip base 3 NO ip base
i have 4507R with dual supervisors (WS-X4013+10GE) with IOS cat4500-ipbasek9-mz.122-46.SG.bin the supervisor module are in 3 and 4, and I want to connection port 5, but i have interface and line protocol down "inactive" error.
So I realized to use command "hw-module" to change the module to GE port. However, I am not able to use the command as" I cannot use the command "hw-module uplink" as well.
i have a cisco Netowtk Analysis module installed on a 6513 core switch which is NAM-1, the version on the NAM is 5.1 and we need to upgrade to the latest version which is 5.1(2)
View 1 Replies View RelatedI am trying to come up with an inventory report of all our 3750v2 stack switches, but for some reason I could not get the serial number of the member switch under each stack. Can Ciscowork LMS 3.2 see the serial number for each switch under a stack?
View 2 Replies View Related