Cisco Switching/Routing :: 5520 Dual Core Switch For Redundancy
Sep 16, 2012
I have the following: 1 5520 ASA connected to the internet, 2 core switches, and several access switches.Aside from implementing RSTP, VRRP, hard code access and trunk ports, is there any other recommendation you would like to add.
I have a setup with two Cat 4506E working as a HA,I used a bundle 4Gb interfaces working as ether-channel,I'm facing a problem with DHCP pools on the both SW's,There is no problem if I use the pools on one sw,But when I but the pool on both sw's then I faced a lot of conflict IP in the DHCP pools,How can setup a real DHCP redundancy on both SW's,
Doing a bug scrub on our dual core, dual Sup 720 6500s tonight. We are going from s72033-advipservicesk9_wan-mz.122-33.SXI4a.bin to SXI9. I want to get a second set of eyes on my script since I have not done this for about 1 1/2 years. Following this doc:[URL]
My network consist of that network device. cisco catalyst 3750 with stackwise, 2xnexsus 5000 series and servers.servers connected to nexsus switch. nexsus connect to 3750.
Each server have two link, one of them connect nexsus1 and other connect to nexsus2 switch.(same traffic) each nexsus have one link to 3750. At 3750 the nexsus link configurate etherchannel. but the flapping occur at 3750.
i understand that at 2 nexsus link have the same server source mac address so the flapping occur at 3750. how i solve this problem?
i configure the uplinks as etherchannel, i configure two svi interface on core switch int vlan 51(192.168.51.1) and int vlan 50(192.168.50.0) for this two svi int i configured two dhcp pool , when any of the pc is requesting for dhcp add i am getting dhcp request failed/
I'm trying to decide what switch to use as a core for 500 users. I'm currently looking at either 2 x 3750X stacks or 2 x 4500s with dual SUPs and PSUs, both options will provide the number of switchports required without the need for additonal access layer swiches. Which switch option is best to go for here? All of our services will be located in our data centre which will be connected using 2 1000Mbps MPLS circuits. I wont need any advanced L3 features and we are not likley to scale over 450 users. Also is it ok to use the dual switch stacks or chassis to provide the collapsed core/access layer or is it best to have a dedicated core (using one of the above options with less switchports) and having a dedicated accesss layer using 2960Gs for example. Our structured cabling terminates in a single comms room so we wont need to distribute switches throughout the office.
I have 2 units core swicth C4510R+E SUP7-E need to connect together for redundant purpose , i bought also 4X 10GE uplinks for each core switches .May i know how i shall connect both core switches together using my spec Catalyst 4500 E-Series 12-Port 10GbE (SFP+) ?
I have a problem with extending the LAN on a client site . They are looking to extend the LAN with a 2960S-series switch. Already in place is a 4510 switch which the 2960 is connected to via fibre. The 2 switches are both set up but there is no connectivity as I cant ping between them or anything. The management VLAN on the 2960 shows line up, protocol down, which I believe means the VLAN is enabled but there is a form of physical mismtach on the ports. I have attached the configs of both switches. I feel it might be a problem with GBIC module compatibility. The SFP installed on both ends of the switch are GLC-SX-MMD. On the 4510, the SFP sits in a twingig converter (CVR-X2-SFP) but there is no light on it at all when the cables are plugged in.
We have two 6500 core switches and one(primary) of them is running in VTP transparesnt mode and the other (secondary) one is running in VTP client mode. I would like to change the VTP mode of the second switch to transparent mode. Would it cause any issue. I guess i have to create VLANs onto the switch.
I have a 3750X four-switch stack acting as the core of a fairly simple LAN. All I need to achieve (and this seems inordinately hard, but it is entirely likely that I'm just being dense) is to get access to the internet through my core switch, through the firewall and out through my VSAT. I've spoken at some length with the firewall providers (Cyberoam) and they tell me all I need to do when I migrate onto my new system (Cyberoam is currently in place at the entrance to our existing LAN) is change the local IP address of the Firewall, plug in the new switch to the LAN port, and away I go. Tried that, didn't work, so obviously I'm missing something.
I am planning to migrate the core switch from cisco 3750 to Cisco catalysts 6513 switch. What could be the best approach to minimize the downtime or avoid disrupting the production. I have couple of thoughts, one method is to build the core and then replace the existing core, another option is to build the new switch as the second VTP server and once it recieves all the VTP information then disconnect the old server.
choosing a core switch, to replace a swich 3com model 4924, its main function is to support a 4-LAN switch cisco 2960 (100 users) and a ring cluster of 12 servers.obs. Current 3com core switch has 56 Gbps performance and 41.6 million packets per second.
We had a core switch(30 vlans) in our environment and it's noticed that CPU utilization of the core switch is showing high during recent days. I have checked logs and processes, but couldn't find the root cause. The issue found only in the office hourly only(after that the cpu utilization is idle and normal). I have already referred the following link to troubleshoot the issue " [URL]
see the following outputs from the core switch
CPU utilization for five seconds: 99%/0%; one minute: 99%; five minutes: 99% PID Runtime(ms) Invoked uSecs 5Sec 1Min 5Min TTY Process 30 6687557041432420936 466 47.52% 47.10% 45.98% 0 Cat4k Mgmt LoPri 55 30667074884269560256 0 45.36% 45.50% 45.85% 0 IP Input 29 28552856922870089254 0 3.59% 3.50% 3.57% 0 Cat4k Mgmt HiPri
[code]....
Note: Each Invalid source mac entry in each day from same port (above is the output after clearing logs before 3 days)
My queries regarding the issues are following
1) How can we find root cause regarding the high cpu utilization?
2) Is a single invalid mac address makes the cpu highly utilized for suppressing it?
I want to upgrade IOS for my production core 3750 switch. Below is Show version/fash output. I have IOS image "c3750-ipservicesk9-mz.122-55.SE7", need to confirm below concerns:-
1-As this is stackable switch do i need to upgrade on all Switch..i can see there are 3 flash while doing show flash? 2-Is above IOS image support with my switch? do i able to enable ssh? 3-is flash memory is enough to succefully upgrade IOS? 4-Any other point which i should keep in mind before upgrading..any special feature which this IOS wont support.
We have two core switches in our network (Cisco WS-4503). HSRP is working as Active-Standby mode. Recently it has been found that core 1 (which is in active mode) shown high CPU load (60% - 100%). Also found that the below mentioned process takes more CPU. Our network consist of around 30 Vlans. We have already checked for the solution in Cisco website [URL] but couldn't find exact reason. see the below outputs for core 1 switch.
Core1# sh processes cpu sorted CPU utilization for five seconds: 55%/3%; one minute: 65%; five minutes: 71%PID Runtime(ms) Invoked uSecs 5Sec 1Min 5Min TTY Process 30 1606933521086983644 147 24.79% 29.93% 35.85% 0 Cat4k Mgmt LoPri 29
i'm already has one internet connection is conecting directily to the Core Switch 6509, and the Switch is route any internet request with default route:
SW6509-conf)# ip route 0.0.0.0 0.0.0.0 10.170.10.10
10.170.10.10 is --> Next hop for the DSL router internal IP, and it's working fine.
We have a new internet connection with another ISP/ with another DSL router, how to connect both of them to exit from the Core Switch 6509.
is it ok if i make another default route to the Next hop to the new DSL router as:
SW6509-conf)# ip route 0.0.0.0 0.0.0.0 10.80.10.10
10.80.10.10 is --> Next hop for the new DSL router internal IP.
To setup SG300-20 as CORE switch and SF100-48 as Distribution switch.SG300-20 will have 2 VLAN(DATA and VOICE)
-192.168.14.1/24 DATA -172.168.0.1/24 VOICE
SF100-48 will also have 2 VLAN(DATA and VOICE)
-192.168.14.1/24 Desktop/Laptops -172.168.0.1/24 IP phones
Problem is when I tried to assign IP to any VLAN's the switch will just hang and loose my connection the light will stop blinking it will steady and i unable to access the switch until i turn off again?
i have new project in hospital with the bellow product :
20 X WS-C2960-24TC-S
2 X WS-C3750X-48T-S
2 X WS-C2960S-24TS-S
i need to configure this switch in order to work first the 2 core switch for redundancy then each catalyst switch 2960 connected to the core with 2 uplink each uplink for each core switch that way i have rendundancy in the connection then i need one vlan ?i need to configure this switch to work perfectly with each other in best redundancy mode?
I am planning to upgrade the current core switch(3750) to 6509 series switch. Since we have a production network running we have to plan for an online core switch upgrade.
We had a core switch(4503) in our environment and recently we tried to enable syslog in the switch. But the syslog server doesnt receives all the configured level messages from the switch. Following is the only message getting in syslog server after the configuration change in switch.
%SYS-5-CONFIG_I: Configured from console by CWLMS onvty1
(No Traffic related messages like acl deny traffic, spanning tree events etc are getting to syslog server as well as log buffer of the switch)
Following are the logging configuration for the core switch
I have an Cisco 6500 CS and there is a Cisco Unified Communication Manger Server connected directly to the Core Switch.I tried to change duplex and speed ( fix and auto ) for both sides, but the same problem.
Is there any challenge to upgrade core switch 6500 series from Nexus 7009 which runs NxOS, because i have 3750X series switches connected at distribution and access layer in my network topology??
Is there any challenge if we place NxOS in core and IOS in distribution and Access layer??? how we are able to match sh run config in existing 6500 switch to Nexus 7009 NXOS?
I wanted to ask a question about the diagram I have included. We are bringing up 2 MPLS WAN connections and would like some specifics on the best design. We are using BGP to the providers. From there we have big questions. We can run BGP internal and are licensed to do so on the N5K's. The N5Ks are currently using HSRP for inside LAN clients as default gateway. We want to load balance and provide redundant routes using a dynamic approach. Should we use BGP internal utilizing the connections between the routers? Should we use HSRP on the routers? How best to get the routes to the N5K and should we be considering this?
We have a problem of igh CPU Utilization in Cisco 4510R-with dual SUP V-10G modules.
Cisco 4510R switch is the CORE switch and have 30 no's of VLans. It was running PVST/PVST+ previously. But Now we have migrated to MST. But after upgradation the CPU utilization reached alomst 98%.
I have a supervisor blade, (VS-S720-10G-3C), in a 6513 that is faulty and needs replaced. Do I need to replace the IOS on the new supervisor blade to make sure it is the same as the IOS image that is on the Active supervisor module, or will it synchronize automatically?
In the synchronization process, the active supervisor engine checks the standby supervisor engine run-time image to make sure that it matches its own run-time image. The active supervisor engine checks three conditions:
# •If it needs to copy its boot image to the standby supervisor engine # •If the standby supervisor engine bootstring needs to be changed # •If the standby supervisor engine needs to be reset
I was reading the above documentation that mentioned the active supervisor should copy the image if it detects a newly installed standby supervisor blade with a different image, is this correct or was it referring to synchronizing the configuration file?