Cisco Switching/Routing :: SG200- 8 Is Not Successfully Booting
Oct 25, 2012
I bought a CISCO SG200-18 switch. I added the Switch to my LAN and started the Switch (as described in the manual). The Switch starts the booting procedure (green blinking status LED) After a while, the LED starts to blink orange and green, instead of steady green.
In generally the Switch seems to work. I can access my whole network, but not the web interface of the switch itself. I also can't see the switch in the ADSL / DHCP rooter.
I also tried to boot the switch only connected to the PC. But ping on 192.198.1.254 is not working. The switch is in the same subnet like my other LAN components.
Subnetzmaske . . . . . . . . . . : 255.255.255.0
Standardgateway . . . . . . . . . : 192.168.1.1
I exchanged the switch. But the new switch shows the same behavior.
View 3 Replies
ADVERTISEMENT
Aug 30, 2012
I have PAT set up successfully on 6506 chassis - My outside address range is 78.24.112.114 255.255.255.240.Relevant parts of the config below: [code] This works fine but of course is only using the one IP address 78.24.112.114.how I can utilize the other outside addresses available or is this not really necessary? I've browsed through loads of Cisco docs.
View 2 Replies
View Related
Nov 17, 2012
Yesterday a coleagu accdently removed the CF card from the router now the router does no longer want to boot completely. It extracts the image from the CF card but when it has to initialize the configuration it stucks there for hours. Can it be that the startup config is somehow corrupted?
When i try to tftpdnld is says that the mac address is illegal.
The first line of the cookie looks like 04 ff 08 86 ff ff ff ff ff ff ff ff ff ff ff ff
System Bootstrap, Version 12.4(13r)T, RELEASE SOFTWARE (fc1)Technical Support: [URL], Inc.PLD version 0x10GIO ASIC version 0x127c2801 platform with 196608 Kbytes of main
[Code]......
View 7 Replies
View Related
Aug 13, 2012
i facing problem with my switch cisco 3560G, when it power on only System light is green and noting happen. i check with serial cable ( Console) but noting happen no booting.
View 2 Replies
View Related
Feb 3, 2012
I have a 6500 that keeps booting into Rommon, even though it has a valid image file on the sup-bootdisk, and the config register is 0x2102. When it reloads I see this on the screen: [code] It seems like the repeating error is "error - on read during ELF program load". I can boot the system off of a CF card, but I'd like to use the sup-bootdisk.
View 11 Replies
View Related
Apr 7, 2012
Yesterday I've faced a Problem that is not letting me boot with the new IOS.
Actually I'm planning upgrade IOS which supports SSH. As part of plan I've downloaded the new IOS image and uploaded via TFTP server to the switch.
After uploading to the switch. I've verified image and MD5 hash also. Everthing is fine. Then after I set the boot variable for the newly uploaded Image.
When I'm rebooting the Device it is not taking the new IOS. It's booting with the OLD image. Even It's not showing any error message while rebooting (ACTIVITY FILE ATTACHED FOR YOUR REFERENCE) I can't take risk by deleting the old IOS.
View 1 Replies
View Related
Nov 3, 2012
I tried to upgrade the IOS on my internal AP and now I am in a reboot cycle. I have tried to manually boot the old and new IOS images from the rommon but neither are working. here is the output I am getting:
ap: dir flash:
Directory of flash:/
2 -rwx 6563840 <date> ap801-k9w7-tar.124-21a.JY.tar
4 drwx 256 <date> ap801-k9w7-mx.124-21a.JA1
152 -rwx 548 <date> env_vars
153 -rwx 2775 <date> cpconfig-ap801.cfg
154 -rwx 2775 <date> back_up.txt
155 -rwx 3763 <date> config.txt
[code]....
View 2 Replies
View Related
Aug 11, 2012
I'm having an issue with 2 of my 3560s which are not booting. The last thing I did on both switches before it hangs was:
>write erase
>reload
restarted as normal
[Code]....
I've tried powering-off the switch and pressing the Mode button and power on. I got to swtch: mode switch:reset
It restarted past the POST but just hang halfway at the same bootp-up process as shown on the attached. The SYST LED is Green color when it hangs.
View 9 Replies
View Related
Aug 22, 2012
I have a new cisco 1941 router that I am setting up with pxe-booting. I have never setup pxebooting before and i have this setup so far ip dhcp pool Admin
-option 66 ip 192.168.1.4
-option 67 ascii pxelinux.0
and i can pull an ip but it keeps getting hung up when it comes to the TFTP part.
View 4 Replies
View Related
Jul 3, 2012
An ASA 5505. Device boots to rommon #0> and stays there. The complete boot record follows:
CISCO SYSTEMS
Embedded BIOS Version 1.0(12)13 08/28/08 15:50:37.45
Low Memory: 632 KB
High Memory: 507 MB
[Code]....
View 15 Replies
View Related
Mar 3, 2013
I have a brand new 3650x switch that I was configuring via console and left it on overnight; this was friday night ( I forgot to keep the air conditioner on). When I returned Sunday afternoon and checked the switch I realized that the SYS and STAT lights on the front were not on, however the Leds on the PS module were still on. I powered it down and turn it on again but still there are no lights on the front. The PS OK and AC OK leds on the PS module are on but I noticed the leds on the two fan modules are not green or even amber; they are off.When I first turned on the switch I remembered distinctly that there were loud noice and if all fans were in overdrive mode for a few seconds then the went to normal. I'm not gettgin this loud noise phenomenom.
View 9 Replies
View Related
Oct 24, 2012
i am facing time daely issues on cisco 2960 s series switch while booting .It is taking time for electing masrer and sleeve for stacking.can i disable the election process for stcking while booting.
View 4 Replies
View Related
Jul 23, 2012
One of the 6500 was going in bootrom mode, so I have formated the flash disk using the other Cisco 6500 switch and copied IOS file to the boot disk. But the 6500 booting failed.
View 6 Replies
View Related
Feb 29, 2012
today I received a Cisco 1841 Router with a problem i have never seen before. Maybe this my 1st really,really broken Cisco Router. When I power the Router on, the fan and all lights turn on (green) and that's it. Nothing changes, also after minutes of wating. On console i don't get any messages and I already tried every BAUD rate possible. Switched the router off/on again and again. And no, it's obviously not a console problem of my computer, because i tried with different routers.
View 3 Replies
View Related
Dec 5, 2011
I have a 4507R with a WS-X4515 supervisor V. It was booting into rommon mode, so I attempted to boot to an IOS image from TFTP. The boot process hangs at at the end of the below output and the then the status light blinks orange. I left it sit like this overnight, and it remained the same.
rommon 23 >boot tftp://x.x.x.x/cat4500-entservicesk9-mz.122-53.SG2.bin
Tftp Session details are ....
Filename : /cat4500-entservicesk9-mz.122-53.SG2.bin
[Code]......
View 9 Replies
View Related
Jul 7, 2012
One of my customer had a problem with A/C and the room temperature reached almost 50 C. We came to the site and saved the configuration, took a backup and shutdown the switch.
After the A/C problem is resolved, we tried to power-on the switch .. and we found that it is going to the rommon.
I put "boot" command to boot from the bootdisk, but I am getting the following error:
Code...
I tried to search it, But it is resulting in that most probably it is a hardware failure on the SUP.
View 6 Replies
View Related
Jul 17, 2012
I have 2950 switch booting through MOnitor Mode.Analyzed there is no Cisco IOS image in flash.
View 1 Replies
View Related
Dec 12, 2012
I have a Catalyst 4506e that works fine but if reload, it boots in rommon mode. I can start it with a boot command, but by default, i must type a command. My config-register is 0x2102.
View 5 Replies
View Related
Feb 28, 2012
I have a cisco 7606-S with dual RSP720-3CXL. Devices reloaded and now none of the RSPs are booting.When I have tried to take the console using only one RSP, card going to rommon mode after that it hangs. I guess its firmware is corrupted.
View 4 Replies
View Related
Jul 17, 2012
I currently work in the IT field part-time as a end-user support technician while I am finishing my Bachelor's Degree in Network Administration. I'm not completely new to networking at this point, but I am by no means a master of it either. The basics of small networks (less than 10 PCs) and the lower-end of small business grade Cisco equipment are not unfamiliar to me. Up until this point however, I have had very little experience with any higher-end Cisco networking equipment.
Now on to the questions, which may seem like the answers should be obvious, but let's face it, I do not have the resources to own much equipment myself at this time for experimentation purposes, nor does the school I am attending have a lot of financial resources to provide us with recent hardware to learn on. What I want to know are a few things about PoE as implemented on Cisco devices, specifically the SG200-50P small business series switch. According to the technical documentation, the switch supports PoE on 24 of its 48 ports, specifically 1 - 12 and 24 - 36; simple enough. The switch is currently installed in an office that has less than 24 connected devices, but that is currently expanding. None of the PoE ports are utilized as of yet, but going forward, there will be more than 24 connected devices. Will another switch need to be installed if the additional connected devices (PCs and printers) are not using PoE, or is the PoE an auto-sensing feature that will simply remain disabled if a device that does not require power over the network cable is connected? Is there some setting that needs to be changed through the management interface to keep devices that should not be drawing power from doing so?
There will likely be some additional questions generated by my inquiry, and I fully understand if these are completely novice questions, but I admittedly do not know the answer. When I Googled it, I was greeted by a few hundred thousand results, the first dozen or so pages of results all being for places to purchase this particular type of switch, so I thought I would try my luck on the forums of the place that made it.
View 1 Replies
View Related
Jul 4, 2012
Does Cisco SG200-50 50 port gigabit smart switch have support for SNMP ? I have updated the firmware and still can not find any option for snmp.Sent from Cisco Technical Support iPad App.
View 3 Replies
View Related
Feb 19, 2013
My SG200-50P Switch Log appears as follows with Random ports going up and down. I am trying to find out if this links to another problem I'm having with a Client Server software locking up on the client end. The hardware, thin clients and desktops, are working and have checked all sleep and power settings. All items in working order, now I'm wondering about the switch
2147483369 2013-Feb-20 15:12:07 Warning %STP-W-PORTSTATUS: gi19: STP status Forwarding
2147483370 2013-Feb-20 15:12:02 Informational %LINK-I-Up: gi19
2147483371 2013-Feb-20 15:12:00 Warning %LINK-W-Down: gi19
2147483377 2013-Feb-20 14:51:31 Informational %LINK-I-Up: gi45
2147483378 2013-Feb-20 14:51:28 Warning %LINK-W-Down: gi45
[code]....
View 1 Replies
View Related
Jul 6, 2012
I was configuring link aggregation between a Cisco3750 and Cisco SG200 and the switched network went down just a few minutes after the port channel came on.I rebooted the SG200 and all hosts came back up for a minute before I lost them again. The etherchannel was between two trunking ports. I never set link aggregation on the SG200, could that be the reason? All machines are connected to the SG200. The 3750 is only being used as a layer 3 device for inter vlan traffic.
View 1 Replies
View Related
Jun 1, 2012
Can a Cisco SG300-10P switch power a Cisco SG200-08 switch over POE? Or an SG200-08P power an SG200-08 via POE? I have an area where I'd like to put a small switch, but would like to avoid having to have electrical power run to it. Or will the SG300 and SG200 POE switches only power endpoint devices such as cameras and IP phones?
View 4 Replies
View Related
May 27, 2013
How to setup a port channel between a SG200 and 3750 and am having problems.
What do I need to do on the SG200 I have added the port into the lag but the port will not come up.
I spent half a day messing arround with the web interface and I am unable to get the port to come up.
The Cisco 3750 is a standard port channel config which I have setup maytime before. channel-group 1 mode active channel- protocl lacp Switchport mode trunk
View 1 Replies
View Related
Mar 18, 2012
I manually set an IP address in my new SG200-26, and turned off the dhcp client. I cannot access the webpage or ping the switch at the statically set IP. I have also run a network scan and tried accessing the switch at all of the IP addresses in my DHCP Pool that were being used, it is not available there either.
View 1 Replies
View Related
Mar 21, 2012
I have two separate companys both with staff at two locations and thier own networks connected with a wireless antenna which provides a high speed LAN connection between offices. I only have a single path through this antenna bridge. I have an SG200-08 switch at each end. What I am attempting to do is utlise the switches to take the two subnets at one office, combine them to one for transfer through the antenna bridge, and then resolve them into the two separate networks again at the other end.
View 1 Replies
View Related
Dec 1, 2012
I have a Cisco SG200-08p that's acting up. After setting up 2 larger 200 series switches I pulled this out for its config. I changed the default password and assigned the new static IP address of 192.168.0.103, that's it. The settings applied and worked normally but after rebooting the switch it reverted itself back to the default ip of 192.168.1.254, it retained the new password. After this happened a few times I upgraded the firmware to the latest version, reset the device to factory settings and applied the new address again to have the same problem. It doesn't matter if I reboot the switch in the management interface or physically. Is there a problem with having a zero in the third octet (that would be lame)?
View 6 Replies
View Related
May 23, 2013
I am going to be putting an SG200-08 (8 port switch) inside a 2U rack mount chassis. To enhance cooling I thought I would remove the outer case. Are there, or would there be any issues with using the switch with the cover removed?
View 2 Replies
View Related
Feb 12, 2013
I was given a task of creating a vlan and isolating one pc to access an internal website (192.168.90.15) on a specific port (port 8080)The pc is connected in the following manner:
PC--> HP Switch --> Cisco Small Business SG200 switch --> 3550 Catalyst 1, 3550 Catalyst 2 and 3550 Catalyst 3.
I have created a vlan 110 on the Main 3550 Catalyst switch and successfully added the pc to that vlan.However, that PC must be able to access the internet and an internal website on port 8080.I have placed an access-list on the main 3550 catalyst switch which is connected to our router as below:
Client ip address: 192.168.100.2
VLAN 110: 192.168.100.3
access-list 110 permit tcp host 192.168.100.2 host 192.168.90.15 eq 8080access-list 110 permit icmp host 192.168.100.2 anyaccess-list 110 deny ip 192.168.100.0 0.0.0.255 ? I was unable to access the webserver even after many attempts.
View 2 Replies
View Related
Feb 12, 2012
I have a Cisco SG200 26 Port Switch, 2 Cisco WAP4410N Access points, and a VLAN aware Router. I have created 4 VLAN's. For the sake of this conversation lets call them.
98 - Intel Vpro
99 - Management
100 - General
101 - Guest
The Access points are capable of doing V LAN tagging so I plan on having them tag a guest network as V LAN 101. That can get sent to the V LAN aware router and out. No problem. I have some devices, or management pages that I don't want accessible from the general network. (Intel V pro KVM, Remote Management Cards, AP Config Menus, Switch config menu...) . I need to be able to take a V LAN unaware device, plug it into port 1, and have it communicate with V LAN 98, 99 and 100.
View 1 Replies
View Related
May 24, 2011
SG200-08 and SG200-08P fail to hold or update Date/Time.(New installation for a UC320 setup.)I've got both an SG200-08 and SG200-08P that are failing to maintain date/time when set with "Use Local Settings". Every restart/powercycle causes them to reset to Dec 31 1969. Other settings save fine.I first tried to set time via SNTP Unicast using a variety of public time server addresses including the 3 hard coded to the SG200-08 firmware:
Sadly though it always just shows "Active Server Server Host Address: 0.0.0.0" and continues having 12/31/1969 as the date. Both after a config save and a reboot.I can ping the NTP servers just fine from the switches either by IP or by hostname.At this point I've decided that I must be missing something simple. At least I hope so... otherwise it's a firmware bug which means waiting for a fix.Other devices behind the same firewall/gateway (RVS4000) are updating NTP
View 2 Replies
View Related
Apr 29, 2012
how to connect our new SG200-18 to an existing Cisco network, in particular a C2960S.Here's what I've got:
<----- Rest of network ------- C2960S ----------- SG200 ----- (PC connected directly to the SG200)
On the C2960S-side here's what I've got on the corresponding interface:
interface GigabitEthernet1/0/1
switchport mode trunk
On the SG200-side I've set the IP-address and default-gateway accordingly, however:From the SG200 I can't ping any other host on the same IP-subnet as the switchFrom the SG200 can't ping the default-gatewaycan't ping from any other host or the default-gateway *to* the switch But:On the SG200 I've got plenty of MAC-addresses under "Dynamic Address Table" - however only MAC-addresses that belong to the management-VLAN of the SG200 (i.e. VLAN9 in my case)The MAC-address table on the SG200 even includes the MAC-addresses of hosts on the same VLAN I tried to ping without success. For example: I tried a PING from a host having a MAC-address of 00:19:bb:31:91:30. This MAC shows up in the arp table of the SG200. To cross check I connected a dedicated PC to the SG200 and assign it an IP-address out of the management-LAN-range of the SG200 - in this case I can access the switch (i.e. PING, WEB etc.)So to summarize: Connectivity is OK when going from directly connected devices to the SG200. No connectivity from devices that are behind the C2960S towards the SG200 and vice versa. (The problem is definitely not with the C2960S-side since we've got plenty of them hooked together without problems.) I'm enclosing the screenshots of the corresponding definitions on the SG200.
View 4 Replies
View Related