Cisco Infrastructure :: Finding Replacement For Switch C4006?
Oct 3, 2012
Right Now we are using Cisco switch model c4006.and we are looking to replacement for the same . Below are our requirements.
1: Around 120 Ports (100 Mbps)
2: Around 30 Ports (1Giga)
3: Layer2/Layer3
View 2 Replies
ADVERTISEMENT
May 28, 2012
I have a cisco 2821 router configured as a CME version 7.1. Now I want to upgrade the IOS to version 15 to get a CME version 8.6 but I faced a problem that the flash of the 2821 is 64MB and the IOS version 15 required flash 128MB. I tried to replace this flash with another 128MB installed on Cisco 2811 router but when I installed the 128MB flash on the 2821 CME the 2821 didn't boot from it.
View 5 Replies
View Related
May 1, 2013
we're running some HP ProCurve 2520's (24 port PoE for desktops/phones) and 2510's for our server racks. The CPU's are a bit weak from what we can tell and sometimes end up with issues on them. The specs on the EAS series look like a decent jump compared to the older HP's. However I've never worked with these ever.
My other option is to go back to Cisco. However to make it fit our budget, we have to dump gig switches for 10/100 + PoE. Which isn't really a major issue on the desktop switches. We'll naturally put gig versions on the server racks. I like our ProCurves, however they cause issues from time to time.
I've also considered going back to Adtran, however I haven't kept up with what they have to offer. I'm tempted to play it safe and go the Cisco route. We're using ASA5510's active/passive for routing/firewall (gig versions).
View 13 Replies
View Related
May 22, 2013
This is an easy question for all the architechs and designers out there. I have a stack of 3508-XL switches and one of them failed. we have 2 spares but hese are more than 10 years old and have reaced EoL.What is the equivalent switch of a 3508-xl replacement today?
View 11 Replies
View Related
Feb 27, 2013
Is there a replacement rackmount kit available for a Smart Switch SF200-48?
View 1 Replies
View Related
Dec 1, 2012
Is it possible to obtain a replacement rackmount kit for a 2960 48 port switch? I've had a read of the manuals but can't see a part number specified. The part number suggested to me (by BT) is for the 8 port version, which is not much use.
View 2 Replies
View Related
Feb 26, 2012
I am looking for an IP Services IOS image for a WS-C3750E-24TD-E switch.Currently have a two switch stack composed of WS-C3750E-24TD-E & WS-C3750G-12S-E.Current IOS running: IP Base.
I need to be able to remove the stub mode for EIGRP, so I am looking for an IP Services image for WS-C3750E-24TD-E switch to be able to run full EIGRP. But I am not able to find one. What is the main difference between WS-C3750G & WS-C3750E switch?Is this even possible for the WS-C3750E?
View 2 Replies
View Related
Mar 8, 2012
I am looking for a Switch with a 10GBE uplink to go with a qnap TS879u with a 10 GBE card.
View 19 Replies
View Related
Sep 2, 2007
I have a switch with part number WS-C4006-S2 , and the fan tray for this switch is faulty, however,i do not know the part number for the fan tray, furthermore, i have found one fan tray's part number in cisco website, WS-X4005= with description :Catalyst 4006 Fan Tray (Spare);my question is i would like know whether WS-X4005= is the correct fan tray for WS-C4006-S2 .
View 2 Replies
View Related
Jul 10, 2012
Any switch that supports 4096 multicast groups?I am working on a system that includes over a dozen catalyst 2960 switches. The customer has pointed out the 2960 switch does not satisfy the requirement to support 4096 multicast groups (even though it is more than adequate for the number of active multicast groups). It looks like the 3560 supports more multicast groups than the 2960, but is still far less than the requirement.
View 1 Replies
View Related
Jun 29, 2012
I recently upgraded my home network to include a new DOCIS 3 cable modem (SB 6121), RV 180 router, and a wireless access point. I have about 7 computers/devices on the network. A computer connected directly to the new modem was pulling down 30MB/sec (various speed tests), but when RV 180 was inserted between modem and network, downloads dropped to 10MB/sec. I worked with tech support (very kind), baselined the router, without improvement, and support conclusion was "hardware issue, need to RMA router".The one thing we failed to configure on the router was the Domain Name (Networking/LAN/IPv4 (local network)/DHCP/Domain Name:). Once I entered the domain name that actually matched the Workgroup / Domain name of the computers on the network, downloads and speed tests jumped to 30MB/sec consistently, and web browsing performance significantly improved.
View 11 Replies
View Related
Mar 5, 2012
I have some problem with WS-C4006 Cisco Catalyst that LMS doesn't collect and put into "never collected" area. I also see that those devices doesn't show the classic prompt ">" and "#". Could be the main problem ? If yes how can configure LMS to recognize a different prompt for devices.
View 1 Replies
View Related
May 23, 2011
I am trying to buy a GLC-SX-MM SFP module via Fed Stock, and I keep getting a GLX-SX-MM. What is the difference between these two part numbers? I can't find it on the Cisco Web site and eve a search of Google comes up relatively fruitless! Is the GLX compatible with my 3750G-24PS switch?
View 2 Replies
View Related
Oct 6, 2012
I have 2 cat3524xl's and a 3550. I recently did something to the IOS that makes the switch not display any output to the console port. Not sure what I did but even doing the reset as instructed in the Cisco docs by holding the mode button foe 2 seconds after boot. I get the flashing green light but still no output. All POST tests pass according to lights so I tried different cables and all baud rates with no change. I hoocked switches back up in lab and can see them in CDP neibors but do not know how to access them from there as they have no IP assigned to them. Remember this is two of them with exact same issue.
View 2 Replies
View Related
Nov 18, 2012
I am trying to add a Cisco SMB SF300 - 24 Switch to an infrastructure which has only Cisco Catalyst Switches The Core layer is Cisco Cataylst 4503 . Distribution is Cisco Catalyst 3560 and the Access Layer is Cisco 2960 Switches.There about 30 VLANs present in the infrastructure which is advertised to all switches using VTP. Inter VLAN routing is done at the Core Switches by creating Interface VLANs for every L2 VLAN.
1. The new VLAN 150 needs to be created on the new Cisco SMB Switch. If I create a corresponding interface VLAN 150 on the Core Switches , will it route traffic to other VLANs just like it is currently working for Cisco Catayst 2960 Switches ?
2. Upon checking I could see that VTP is not supported on Cisco SMB Switches and I would need to go for GVRP if I need to advertise VLAN information to other Switches. But since GVRP is supported only on CatOS and there is no inter operability between GVRP and VTP , I would need to create VLANs manually on the new Switch . Is that correct ?
View 8 Replies
View Related
Apr 15, 2013
What needs to be done to convert a WS-C3560G-24TS-E to DC power?
View 2 Replies
View Related
Mar 3, 2013
Is it possible to manage the switch SMB 300 series using Cisco Prime Infrastructure 1.2?
View 1 Replies
View Related
Oct 4, 2012
Can We use Cisco HWIC-4ESW as no Switch Port.
View 5 Replies
View Related
Jul 27, 2011
A customer is expanding their network into another wing, and they have a good number of existing Small Business switches (specifically the SGE-2010P - [URL] that they're interested in possibly deploying. They have a full-blown Cisco infrastructure and voice deployment (Cat 6500 core switches, 3750 switch stacks, Communications Manager w/ over 1,000 phones, etc.).
The general concern is whether there is ANY known issues or concerns with trying to mix/integrate the Small Business equipment with non-SMB infrastructure. Looking at the datasheet for this switch, it's clearly PoE, supports QoS, although it doesn't specifically indicate it can provide a voice/auxiliary VLAN for a phone detected by CDP - that would be a big deal. So basically, "a switch is a switch", and I'm just posing this question to make sure there's no reason (technically or from a support standpoint) that we would not recommend integrating these.
View 1 Replies
View Related
Jul 9, 2012
Seeing very strange behaviour my 2811 Router is sitting behind 3650 switch, when the link between switch and router is trunk the router start rebooting itself, to test i changed to access mode then I can see ip address of router on cdp neig de or else not seeing ip address of router.
View 3 Replies
View Related
Jan 2, 2013
I'm using a Catlyst 3550 to supply power to a IP network surveliance camera. By default, the predecesor to POE, Cisco Inline Power allocates 15.4 W of power to a port ... What is the process for reducing this power output?
"For an IEEE device, the switch always allocates 15.4 W to the port. The switch does not display the IEEE class type in the show power inline privileged EXEC command output. Instead, it displays n/a."
View 2 Replies
View Related
Nov 15, 2005
My switches is still operating but when i ping the switch, there isn't any reply. No icmp reply from catalyst 2950 switch
View 6 Replies
View Related
Jan 24, 2012
I need the temperature oid for cisco 1841 and 2960 switch.
View 1 Replies
View Related
May 24, 2011
My issue: I have installed a firewall within my network. Currently all my clients default gateway defaults to GW:192.168.1.1. I would like all my internet traffic to route to the firewall ip 192.168.1.30. My Primary switch ip is 192.168.1.10, which is a 3560G running 12.2(25)SEE2 IPBASE-M.
My main problem is, I do not have access to the gateway, so I am trying to route internet traffic from within my switch to the firewall. I have already tried Route-Map, but seems this version of the OS does not support. I have already tried Policy-Map, but same as above. I have also tried IP ROUT command, but it did not work either.
And remember, I would like to perform the routing from the switch, because I do not have access to the default gateway which is a router to perform forward internet traffic to the firewall.
View 4 Replies
View Related
Sep 18, 2012
WS-C2960G-24TC-L 12.2(25)SEE3 C2960-LANBASE-M
I would like to get the temperature status from this 2960 switch (and several other models. Normally this OID should be:.1.3.6.1.4.1.9.9.13.1.3.1.6 But it does not return anything.
The termperature status can be found from the command line by running:"sh env temp" This reports back ok, so I assume there is a temperate gauge in the switch.
This oid is part of the "CISCO-ENVMON-MIB" mib and accouding to the Cisco MIB selector it is supported on my switch and IOS - 12.2(25).
(Another thing I woudl like to monitor and should be supported is the fan status oid (.1.3.6.1.4.1.9.9.13.1.4.1.3). That doesn't return anything either.
What do I need to do to get the temperature environment status from SNMP query?
View 3 Replies
View Related
Apr 7, 2011
I have set up an ACL on my 3750 switch to deny icmp from PC A on our inside network to PC B on a different VLAN on our inside network using the following ACLs:
deny icmp host 10.1.17.15 host 10.3.10.4
deny icmp host 10.3.10.4 host 10.1.17.15
-- or --
deny icmp host 10.1.17.15 host 10.3.10.4 echo-replydeny icmp host 10.3.10.4 host 10.1.17.15 echo-reply
These ACLs belong to an access-list that also limits ip traffic to a few specific machines.When I try pinging from PC A I receive a reply message back from PC B. Shouldn't this configuration block any ICMP from PC A to PC B and from PC B to PC A? I would have expected the first ACL statement to block any packets associated with ICMP and when that didn't work I tried the second configuration.
View 6 Replies
View Related
Apr 12, 2005
Is it possible to enable login by http (web interface) to catalyst 4006 switch with WS-C4006 Software, Version NmpSW: 6.3(5) ?
View 21 Replies
View Related
Apr 18, 2013
I have windows server 2008r2 running a FTP server, so I can back up my configs and upgrade IOS when needed. My problem is than I can backup to the server just fine but when i try and restore a config or pull a new IOS over it gives me this error
%Error opening ftp://13****** (Protocol error) this is happening on every switch I have and I can't figure it out.
View 4 Replies
View Related
Aug 25, 2012
I have been experiencing a strange problem i have a switch stack of 3750 in which 4 switches are cascaded. there is one one switch shows PROVISIONED status when I run "show switch". i have verified the stack cable connectivity its OK.
now when i try to console that particular switch i am unable to access it as well. I tried to reboot that switch and on reboot it only shows one LED syst blink once and after that remains constant and nothing happens to other LEDS. from the back of the switch FAN is working fine.
View 4 Replies
View Related
Jun 25, 2012
I have a couple of Switches Blade 3120, working as active-standby model (HSRP) on a new site deployment. There are other 20 sites more or less, working on the same model, without issues. But in this one, we are seeing a high cpu usage. The traffic going through the platform is 600Mbps (on peaks), and in this case we have 40% of CPU usage. Traffic should be close to 3 Gbps. When we tried to send the whole traffic through the platform, active switch began to drop packets on the majority of interfaces.
When we analyze the CPU usage, there is a special process called "HL3U bkgrd proce" always have the most CPU use, but we do not know what concerns. We do not know if it is caused because there are PBRs configured. It should not matter. How I mentioned, there are other sites working fine and have had always the same PBR number.
What is causing the high usage?. Is there a special debug we could to perform to diagnose the issue?. Also, we have seen a high interrupt CPU usage (9% in this case).
bog-sib-INT-rtr-1#show processes cpu sorted 5sec
CPU utilization for five seconds: 30%/9%; one minute: 25%; five minutes: 23%
PID Runtime(ms) Invoked uSecs 5Sec 1Min 5Min TTY Process
[Code].....
View 3 Replies
View Related
Apr 15, 2011
I have several 2960s and 3750s and two 6506 (ws-cac-3000w) recently move to new location The power outlet is the same ,but Volt is different current 2960/3750 use this(one phase 3 wire) 220v and new location change to (from 3 phase 4 wire -> one phase 220v)6506 current using(one phase 3 wire) and will be change to (from 3 phase 4 wire -> one phase 220v)
I had search doc about power supply /cable , only show support single phase 220 v ,but not description vlot between each wire !!Does new location power outlet suit for 2960/3750s power and 6500 ws-cac-3000w ?!? Do I need chane power outlet back to current using?
View 1 Replies
View Related
Jan 18, 2011
Customer is using AIM-ATM AIM with a VWIC2-1MFT-T1/E1 card installed, and using the E1s in ATM mode.They have recently migrated to ISRG G2, but; ISR G2 (2911) dosen't support AIM Modules, and there is no relevant module for ATM.So is there anything we can do to accomplish same functionality on ISR G2 ?
View 1 Replies
View Related
Jul 1, 2012
I'm looking to upgrade our main router/firewall with something that has more throughput. This unit has 2 DMZ zones, internal switch and 2xWAN connections which is pretty handy as I'm utilizing all of them.How to resolve the issue of having a firewall and router in one device,What would be the replacement solution if I were to decide for Cisco solution? What is the best practice?
View 3 Replies
View Related