Cisco Wireless :: How To Power WAP200E
Jun 6, 2011
how to power a WAP200E. In the datasheet it mentions it supports POE, however the customer does not have a POE switch and for one WAP220E is not willing to purchase.
What other options do we have? Is there a power supply for this AP?
View 4 Replies
ADVERTISEMENT
Jan 15, 2013
directional antenna for the WAP200e.
I've been googling but can't seem to find a product. I have found omni-directional but no directional antennae
View 2 Replies
View Related
Sep 9, 2012
I want to know what is the maximum range of WAP200E. I found in an overview of the family of access points "CISCO SMB" that could reach up 4kms. Is that true?
View 3 Replies
View Related
Sep 17, 2010
I'm trying to bridge two buildings with two WAP200E. The connectivity is fine, but I'm only able to get one VLAN through the bridge. That is the default VLAN 1 wich is untagged. I have two additional VLANs wich is tagged. I can not get these two through the bridge. I have set up a single SSID, and enabled VLAN. I have also tried to set up more than one SSID, mapping each VLAN to separate SSID's, but bridging several SSID's between two AP's make the AP's loose connectivity periodically. What would be the propper way of bridging several VLANs between two WAP200E ?
View 1 Replies
View Related
Mar 1, 2009
I am having trouble with an pair of WAP200E's. The bridge between them stalls, found that one of the AP wireless LED don't show any activity. After powercycle the stalled AP, the bridge works again for a day or two. Have tried to replace the AP's still the same issue
Firmware is 1.20a
View 15 Replies
View Related
Apr 19, 2012
Just setup two WAP200E's, the bridge is "Connected" as I look Status > System Performance in both WAP's. However, I cannot get to the LAN from one network to the next. Cannot even ping the WAP's from either side.
I already have two WAP200E's on this network, that have been working well for month (164 day uptime), and they are configured with a wireless bridge between them, both networks on the same LAN (same 192.168.2.x network on either side). The bridge names are different, different from the main WiFi in the building, too (if it makes a difference), and the static IPs the WAPs have don't appear to have any conflicts on the network.
This is actually three buildings, one is the main one with a Cisco SR520 for a router, and a Cisco SF 200-24P switch. So two WAP200E's go into this switch now, and I see them both fine when going into the management interface. Then each of the other buildings has one WAP200E, and a small Netgear 8 port PoE gigabit switch at each building to power the WAP.
The Netgear switches aren't managed, and I've made sure any features like STP, VLANs, etc. are turned off. And the Cisco SF 200 switch is set at auto and all the defaults mostly, particularly for the ports. I tried doing a SmartPort for this latest WAP200E and that didn't change anything, tried disabling STP for it too, and no change. The PoE port for the working WAP200E is identical in config to the PoE port for the new WAP200E, and both show forwarding, all VLANs admitted (none are enabled, no VLAN tagging, etc.).
So now I am wondering if I can have two WAP200E's into one switch? Or two bridges on the same LAN subnet? Or is there something else I am missing or should configure?
View 1 Replies
View Related
Apr 23, 2012
WAP200E access point that causes it to reboot after anything from 15 to 20 mins .I have run it off an injector and a POE switch, updated the f/w to WAP200E-ETSI-FW-2.0.3.0 and it still reboots itself .I have even been sent a new one from the supplier and it does the same thing.
View 5 Replies
View Related
Aug 18, 2012
I purchased a Linksys WAP200E Wireless-G Exterior Access Point – PoE and a HGA9N (9dBi) High Gain Omni-Directional Antenna through CDW Canada about three (3) years ago in April/2009. The first year it worked great and gave complete coverage throughout the Campground. The second year it started to become increasing less coverage and now in the third year, it has very poor coverage. I have purchased and installed a new Microcom HG2415U-PRO (15dBi) HyperGain Outdoor Omni Directional Antenna. This has NOT made any improvement so I am now thinking that the WAP200E Access Point is the faulty equipment. I have changed the channel to number 11 and still no improvement. The Signal Strength is only Good and then dropping to Fair and sometimes no signal at all. This is from a line of sight location that is only 60 yards (180 feet or 54.9 metres) away. There are no objects between the Antenna and the computer.
View 3 Replies
View Related
Jan 7, 2013
I have 3 WAP200e APs in a client site and I am having a problem with the signal between the APs and Motorola 9000 barcode scanners.The first one went in about 6 months ago and it worked fine. The client then asked for two more to be installed in a couple of rooms adjacent to the room where the first AP was installed. They use barcode scanners with these APs and since the two new ones were installed, the first on is dropping the connection to the scanner. I have turned the new APs off and everything is back to normal. I have reduced the power output of the two new APs and the situation has improved, but they still get problems, especially on Monday morning, where it won't work at all for the first few hours, and then bursts into life and works fine for the rest of the week.
View 7 Replies
View Related
Jun 7, 2011
Is it possible to connect two WAP200E on bridge mode without external antennas if they are 200 mts. (219 yard) apart?
View 2 Replies
View Related
Jun 9, 2011
i would like to know if wap200e will still have connection if there are trees in between. because we have 2 offices that is 200 meters apart and trees all over them. i just wanna know before we buy the unit.
View 1 Replies
View Related
Jun 26, 2011
I have a customer with a linux OS machine running Cisco Wireless Controll System.
He needs are to add a new wireless AP with the following features :
- compatible with most laptops
- exterior conditions "resistant" (sun, rain...)
- reasonnable performance (the AP would be a a roof with people on the roof itself, max distance : 15 meters, no walls)
I saw the WAP200E but I have no idea, if it is compatible with Cisco Wireless Control System
View 2 Replies
View Related
Jul 21, 2011
I keep getting alerts from our WCS stating that our 1252s are drawing low power. Now I am aware that they require enhanced PoE (up to 20W) but as we only have standard PoE in that building we purchased the 1252 series power injectors to go with them.
However, even with the correct power injectors the WCS still reports the draws low power error.
Is this a bug? Running WCS 7.0.172 at the moment.
Forgot to say we are using the PWR-INJ4 and the injector status is enabled and you see the injector MAC address when you drill in to the AP status.
View 9 Replies
View Related
Oct 25, 2012
I have a problem to connect my WAP200E to SW2960. What is my mistake?Both are POE. I connect only Wap200e to SW2960 and I check the 15.4watts, but I suposed that WAP 200E doesn't respond, because WAP 200e doesn't turn on.I need to put to grown, or put some device before on connect to SW2960 to WAP 2000E.
View 10 Replies
View Related
Nov 7, 2011
Because of a connection problem, I would like to know where I can see the clients associated to a WAP200E AP and the signal level of each client.
View 1 Replies
View Related
Jun 21, 2012
I'm using 4 wap200 cisco AP, 1 wap200e linksys AP and 1 cisco sf300-24p switch. Every AP has 2 SSIDs,one is for clients and one for mobile devices.I have updated the equipment to the latest firmware but I still encounter the same issue. The mobile devices go through APs and once every 2 days, my wap200e blocks its lan interface. I suspected a stp issue, because the switch was seeing MAC addresses coming from different ports.So I disabled STP on the switch and on the AP. The annoying thing thing is that none of my other antennas get cut off.I tried replacing it with a cisco wap200e,same issue.
View 1 Replies
View Related
Jun 9, 2013
I am receiving the following error on 3750 stack switches. have already verified the power status and found ok.
IOS used: Cisco IOS Software, C3750E Software (C3750E-UNIVERSALK9-M), Version 12.2(55)SE3, RELEASE SOFTWARE (fc1)
211540: Jun 10 10:45:17.935 UTC: %PLATFORM_STACKPOWER-4-UNBALANCED_PS: Switch 4's power stack has unbalanced power supplies
211541: Jun 10 10:46:18.045 UTC: %PLATFORM_STACKPOWER-4-UNBALANCED_PS:
[Code]....
View 1 Replies
View Related
Sep 4, 2012
After stacking two 3750X switches, with four equal power-supply's, with StackWise and PowerStack , still got the next message every few hours %PLATFORM_ENV-1-FRU_PS_ACCESS: FRU Power Supply is not responding (gn4m-rt1p08-04-2)( note that the message revers to the second switch in the stack ) although the stackwise and powerstack on the switches is oke and are working correctly. !
Config : Stack-power in power-sharing mode/strict With CLI on the switch : All the power supply's and stack-power details, prio look OK.
Only: LMS prime /inventory/cisco-view/configure/power supply status result : some power supply's are marked as disabled.with the command > power supply 2 slot a off/on I manage to get the status back to "normal", but after a few hours some power supply's are again marked as "disabled".
Looks like SNMP en IOS difference from opinion.
Hardware
WS-C3750X-24S-S
C3KX-PWR-350WAC
Software
15.0(2)SE
C3750E-UNIVERSALK9-M
View 5 Replies
View Related
Apr 14, 2013
We have two switches of the same model (WS-C3560-48PS-S) that are not providing PoE. I'm trying to remotely determine what the cause of the issue is.
Here is some output.
Hostname#show power inlineAvailable:0.0(w) Used:0.0(w) Remaining:0.0(w)
Interface Admin Oper Power Device Class Max (Watts)--------- ------ ---------- ------- ------------------- ----- ----Fa0/1 auto off 0.0 n/a n/a 15.4Fa0/2 auto off 0.0 n/a n/a 15.4Fa0/3 auto off 0.0 n/a n/a 15.4Fa0/4 auto off 0.0 n/a n/a 15.4Fa0/5 auto off 0.0 n/a n/a 15.4Fa0/6 auto off 0.0 n/a n/a 15.4Fa0/7 auto off 0.0 n/a n/a 15.4Fa0/8 auto off 0.0 n/a n/a 15.4Fa0/9 auto off 0.0 n/a n/a 15.4Fa0/10 auto off 0.0 n/a n/a 15.4(code)
View 1 Replies
View Related
Feb 28, 2011
I have a 6500 chassis with 2 power supplies. At the moment I am using the default configuration:
power-redudancy mode redundant
The problem is that an inserted module is in "power deny" state due too insufficient power.
I know, that It's not a good idea to change into combined mode (loss of redundancy), but my customers requested this anyway.
So I will change to combined mode. So here's the 1 million dollar question: "Which modules will go into power deny, if one of my power supplies fails?"
The 6500 config guide states:
"Power supply is removed withredundancy disabled
• System log and syslog messages are generated.
• System power is decreased to the power capability of one supply.
• If there is not enough power for all previously powered-up modules, some modulesare powered down and marked as power-deny in the show power oper state field."
Well, do you know if there's any way to configure some kind of priority? E.g. I definetly don't want by 10Gig Module or WiSM module to be in power deny. Can i statically make sure, those module will be powered on for sure? Like: "power enable module slot_number" How is this calculated? Or is random?
View 3 Replies
View Related
Apr 4, 2012
In a stand alone 3750x switch configuration, can the secondary power supply only act as a redundant power supply (active/standby), or can it become a "pool" of power similar to power sharing mode for StackPower (somewhat active/active)? I understand there is no stack involved here but I'm curious if this functionality is possible.
View 1 Replies
View Related
Dec 5, 2012
how can I enable an automatic power-on after a power failure on an ASA 5512-X?
View 5 Replies
View Related
Mar 3, 2013
how can I enable an automatic power-on after a power failure on an ASA 5512-X?
View 12 Replies
View Related
Dec 4, 2012
I have a WAP4410N that stopped powering on with PoE. The PoE light comes on but the Power and Ethernet light remain off. The link light comes on the port on the switch. I have tried multiple switch ports and tried a different switch.
View 3 Replies
View Related
Jun 5, 2012
I bought a Cisco WAP121 and a Cisco AIR-PWRINJ3 so I could use the PoE from the AIR-PWRINJ3 to power the WAP121. Unfortunately the setup is not working, the WAP121 shows no sign of getting power even though the AIR-PWRINJ3 indicates it has power. Is this setup just not supported or do I have defective parts?
View 5 Replies
View Related
Jun 28, 2011
I need a power Injector compatible for WAP 4410N.
View 3 Replies
View Related
Oct 20, 2011
Do I need to plug in AP 1262 into a PoE switch or external power adapter before can power on? How about LAP 1262? Do I need PoE switch as well?
View 4 Replies
View Related
Dec 12, 2012
i have AIR-BR1310G that came with its proper power injector AIR-PWRINJ-BLR2 can this power injector be feed using a POE switch or do i have to use the 48v power adapter
View 1 Replies
View Related
May 13, 2010
I'm facing the following doubt regarding the AC Power Connector on the 1522 AP.We are powering up the AP through PoE, so the AC Power Connector is not used.BUT,do i have to seal/protect the connector or leave it as is?
View 3 Replies
View Related
Apr 24, 2013
What is the required power by WAP321 ? There's no information about IEEE 802.3af class at the datasheet.
View 1 Replies
View Related
Sep 3, 2012
I have a cisco wireless power injector for Aironet 1250 but I called Cisco and was told this can't be found in the system.
View 9 Replies
View Related
Feb 28, 2013
My question is about the maximum possible transmitting power in a Cisco 1242AG-E-K9.I did an update of my AP on a new ios version and since then, the maximum power for me is limited to 17 dbm. I check this within the console and the "show controllers dot11radio0 | include Power:" command. I thought that I had 20dbm before the update, but unfortunately I can't proof this by myself because I have no AP left with the old firmware.
Is it possible that the upgrade did this? I read about the regulatory domains for the transmitting power. I live in Switzerland, so I thought I could use 100mW if I want to. I read it's not possible to use the 100mW at each speed but I think I should stull be able to select the 20dbm/100mW or am I missing something?
View 3 Replies
View Related
Aug 2, 2011
if the Cisco Power Injector (AIR-PWRINJ3=) is compatible with the 541n AP ? I find info about compatility with other AP models but didn't find any related with this SMB model.
View 2 Replies
View Related