Cisco Switching/Routing :: 5884A9C - Getting Debug Message On Switch

Sep 3, 2012

I have a message that appears when i run a debug on my switch :
 
Core1#pak 5884A9C consumed in input feature , packet consumed, MCI Check(63), rtype 0, forus FALSE, sendself FALSE, mtu 0, fwdchk FALSE

View 1 Replies


ADVERTISEMENT

Cisco Switching/Routing :: Can't See Any Debug Message On 1800 Router

Jul 19, 2012

I have strange problem with 1800 router , I can't see any debug messaging , the ping from PC to this router is Ok , but no icmp debug appears , even I enable "debug ip icmp "  the version of router is : C181X Software (C181X-ADVENTERPRISEK9-M), Version 12.4(6)T6

View 2 Replies View Related

Cisco Switching/Routing :: How To Debug A TCAM Switch On 877W

Feb 24, 2012

I've created a BVI2 where I bridged dot11 0.2 and vlan2 in order to have wired and wireless clients in the same vlan.Some wired client are not reachable from the lan. Wireless clients have no pbl in reaching each other.Monitoring a MAC address that is supposed to be behind the FA2 I have noticed that it moves to vlan2 when in fact it should be behind the FA2.Of course when "show mac-address-table" says it is behind Fa2 the ping to that MAC address works whereas when the TCAM reports it is behind vlan2 it doesn't. Once the MAC address is behind the vlan2 if I clear the mac-address-table and that mac-address is still put behinf Fa2 then the pings works again, sometime I have to perform twice the clear command before the MAC address goes back to the right location.I'd like to understand why the router moves that MAC address from Fa2 to vlan2 and that's the reason for my question in the subject.I don't have any problems for port Fa0 and Fa1."Show int fa2" doesn't show any problem/errors or the likes.BTW even if I force that MAC address to be statically behind FA2 the ping works fine but then stops and if I do "show mac-add" the static entry for it is still there... so looks like there us something that overrides that static entry. If clear everything and I have the mac-address be behind Fa2 then everything starts to work again. I used Fa3 instead of Fa2 and I get the same results.
 
IOS: c870-advipservicesk9-mz.151-3.T1.bin

View 5 Replies View Related

Cisco Switching/Routing :: 3750E Debug Causes Switch To Crash And Reload

May 3, 2013

I am not able to find the exact bug for Cisco 3750E stack - Debug Exception (Could be NULL pointer dereference) Exception (0x2000) error. Closest i can find is CSCsa72400 which only affects ver 12.2(20)SE4.All the stacks (3 switches) are running 12.2(50)SE3, It appears that the switch 1 crashed and reloaded. My hunch is its software but i cant find any related bugs. It could be hardware issue as well ?

View 4 Replies View Related

Cisco Switching/Routing :: Command To Debug Packets On 3750 Switch

Apr 18, 2012

What other command can be used to debug packets on a 3750 switch ?

View 2 Replies View Related

Cisco Switching/Routing :: 4507 Switch Port Duplex Message?

May 3, 2012

what is causing " Gigabit port is restricted to full duplex" while trying to hard code speed/duplex on a 4507 switch port?

View 3 Replies View Related

Cisco Switching/Routing :: What Logging Buffered 51200 Debug Do

Jan 7, 2013

what logging buffered 51200 debug do?i saw it on cisco 881 sec k9

View 1 Replies View Related

Cisco Switching/Routing :: Debug Command Not Working On Nexus 5548?

Nov 15, 2012

My Nexus is a 5548-UP model, NX-OS version :  5.1(3)N2(1b)
 
I try to debug an OSPF and an ICMP problem using the debug ip ospf command and the debug icmp command but not output appear on the terminal. As the switch is remote, I entered the terminal monitor command of course.
 
SG01NX01# terminal monitor
SG01NX01# debug ip ospf 1 packets
SG01NX01# show debug

[Code].....

View 2 Replies View Related

Cisco Switching/Routing :: 6509 Debug Spanning-tree Functions In Lab

Nov 9, 2012

I'm testing debug spanning-tree functions in a lab, hardware is Cisco 6509 with SUP-720-3B and WS-X6748-SFP, IOS is 12.2.33.SXJ. It's a root in some vlan's, stp mode is rapid-pvst.I wanted to see how spanning-tree is working (STP packets dump, etc.), and entered following commands on 6509: [code]
 
Then, I turned the "debug spanning-tree all" mode on. Now, I expect to see BPDU packets from Cisco, and other spanning tree events in logs on syslog server, or in log buffer, but I don't get anyting there. Except, there're some lines in log (they repeat very rare): [code]

View 3 Replies View Related

Cisco Switching/Routing :: Message Error With C3750-I5-M

Jan 2, 2008

I have this system: IOS (tm) C3750 Software (C3750-I5-M), Version 12.1(19)EA1d, RELEASE SOFTWARE (fc1
 
An error appear in console (many times in one minute):
 
Jan  3 16:25:37: %LINK-3-BADMACREG: Interface StackPort1, non-existent MACADDR registry for link 0
-Process= "<interrupt level>", ipl= 4
-Traceback= 20A364 187F04 58D6FC 58B950 2D7CE0 2E00C8 2E2BEC 2E2F24 2B0BF8
 
What is the problem? What is the solution?

View 2 Replies View Related

Cisco Switching/Routing :: C4948 - Message In System Log

Apr 29, 2013

I'm using "WS-C4948(12.2(54)SG)+PWR-C49-300AC/2". The following message are logged in the system log, but it was to check the status with the show command and status LED, but there was no abnormality. I thought the power supply has failed, but I seem different.

040861: Apr 27 07:00:50: %C4K_IOSMODPORTMAN-4-POWERSUPPLYBAD: Power supply 1 has failed or been turned off
040862: Apr 27 07:00:50: %C4K_IOSMODPORTMAN-4-POWERSUPPLYFANBAD: Fan of power supply 1 has failed
  
I checked.>> #show environment alarm no alarm
#show environment status power supply
Power                                             Fan      Inline
Supply  Model No          Type       Status       Sensor   Status
------  ----------------  ---------  -----------  -------  -------
PS1     PWR-C49-300AC     AC 300W    good         good     n.a.
PS2     PWR-C49-300AC     AC 300W    good         good     n.a.
 
All Status LEDs are green.

View 5 Replies View Related

Cisco Switching/Routing :: Error Message On CAT4507

May 8, 2011

I've taken 2 4507's fresh out of the box running CAT4500E-ENTSERVICESK9-MZ.122-53.SG2.BIN which was upgraded from CAT4500E-IPBASEK9-MZ.122-53.SG2.BIN
 
I'm getting constant %C4K_S2W-4-WRITECALENDARERR:  Calendar write operation Failed errors on the console.  I was also getting them on the original IOS version.
 
Anything I've seen say's to ignore them but their very frequent filling up the logs.
 
There's very little return on google and no bugs to report on Cisco?

View 8 Replies View Related

Cisco Switching/Routing :: Nexus 7009 Error Message

May 27, 2013

I have in logs following error message:

%DEVICE_TEST-2-PWR_MGMT_BUS_FAIL: Module 1

Has failed test SpineControlBus 20 times on device Power Mgmt Bus on slot 10 due to error Spine control test failed error number 0x00000002.

View 3 Replies View Related

Cisco Switching/Routing :: Ambiguous Error Message On Cat6500 VSS

Nov 15, 2012

I get a unclear log entry in a VSS system.

Me_Kr #1        ME_KR_ERROR_CNT_LTL_PARITY_ERR_ITRP_0_0[01C8] : INTR= 0001 MASK= 0001
Me_Kr #1        ME_KR_ERROR_CNT_LTL_PARITY_ERR_ITRP_0_0[01C8] : INTR= 0001 MASK= 0001
Me_Kr #1        ME_KR_ERROR_CNT_LTL_PARITY_ERR_ITRP_0_0[01C8] : INTR= 0001 MASK= 0001
Me_Kr #1        ME_KR_ERROR_CNT_LTL_PARITY_ERR_ITRP_0_0[01C8] : INTR= 0001 MASK= 0001

[code]....

View 1 Replies View Related

Cisco Switching/Routing :: 3750 - Error Message While IOS Upgrade

Jan 6, 2013

Have a small stack of two 3750 routers.  Get the following error message every few secounds:
 
%STACKMGR-4-STACK_LINK_CHANGE: Stack Port 1 Switch 1 has changed to state DOWN
%STACKMGR-4-STACK_LINK_CHANGE: Stack Port 1 Switch 1 has changed to state UP
 
Now I replaced the stacking cables but no joy. It was ok for an hr or so but then the error messages popped up again. Also random links on this stack back to access layer user switches have been going up and down randomly. So I have decided to take the next step and upgrade the IOS.
 
 Although when I try and copy a new IOS I get the following error:
 
%Error writing flash:/c3750-ipservicesk9-mz.122-55.SE6.bin (No space left on device)
 
Seems this image is 130MB while the image that is currently on it is 74MB and free space is 54MB. How do I get the image onto the router? If I delete the current image from flash will that cause the router to stop functioning?
 
Also I noticed there seems to be more than one flash directory. See below:
 
copy tftp: ?
  flash1:         Copy to flash1: file system
  flash2:         Copy to flash2: file system
  flash:          Copy to flash: file system
  null:           Copy to null: file system
  nvram:          Copy to nvram: file system
  running-config  Update (merge with) current system configuration
  startup-config  Copy to startup configuration
  system:         Copy to system: file system
  vb:             Copy to vb: file system
 
The current router image seems to be in flash1 and flash 2 also. Could I delete the image from flash1. Upload it there and then boot the router from flash1?

View 16 Replies View Related

Cisco Switching/Routing :: C3950 - Intermittent Message / May Suspend At Level 4

Jul 16, 2012

For a week now, one of my Cisco 3945 routers displays, from time to time, the following message in its log:
 
2012-07-16T14:12:43.852017+00:00 cb00-r103 220: [syslog@9 s_sn="59"]: Jul 16 16:12:42 MEST: %SYS-2-INTSCHED: 'may_suspend' at level 4  -Process= "OSPF-100 Hello", ipl= 4, pid= 320
2012-07-16T14:12:43.852017+00:00 cb00-r103 221: [syslog@9 s_sn="60"]: -Traceback= 15CB073z 9081B7z 2851571z 11B7582z 11C275Ez 11C2906z 11C03E3z 1B907B5z 1B9064Cz 1BA5737z 172047Fz 47FFDCz 4D2EEDFz 4D2ED71z 4D2EA2Bz 4D30097z
2012-07-16T15:06:11.686817+00:00 cb00-r103 222: [syslog@9 s_sn="61"]: Jul 16 17:06:10 MEST: %SYS-2-INTSCHED: 'may_suspend' at level 4  -Process= "OSPF-100 Hello", ipl= 4, pid= 320
2012-07-16T15:06:11.686817+00:00 cb00-r103 223: [syslog@9 s_sn="62"]: -Traceback= 15CB073z 9081B7z 2851571z 11B7582z 11C275Ez 11C2906z 11C03E3z 1B907B5z 1B9064Cz 1BA5737z 172047Fz 47FFDCz 4D2EEDFz 4D2ED71z 4D2EA2Bz 4D30097z

[code]....
 
It never happened before and the configuration did not change. The only thing that happened, the WAN connection (point-to-point to a Cisco 3845) went down and the router rebooted while the WAN was down. When the WAN came up again, everything went fine, until about an hour later and the first occurrence of this mentioned log.This 3945 does establish an IPSec tunnel with its peer (the 3845) and all the traffic, including OSPF, is going through the tunnel. 

View 4 Replies View Related

Cisco Switching/Routing :: 6500 MSFC2 Strange Error Message

Jun 5, 2011

my MSFC2 sent this strange log message. %DATACORRUPTION-SP-1-DATAINCONSISTENCY: copy error, The error message decoder tool says: "NOT FOUND". The level is "alert".

View 8 Replies View Related

Cisco Switching/Routing :: Catalyst 4948 Power Error Message

Dec 20, 2010

We are running a small network business and as funs of ciscos we own a some of the 4948s.We are facing an issue with couple of them as we get the below error message

C4K_CHASSIS-3-INSUFFICIENTPOWERSUPPLIESDETECTED:Insufficient power
supplies present for specified configuration

First thought to replace the power supply didn't actually work as we did that with no result.Power consumption is not an issue as well because all other 4948s work fine with 1 power supply (forgot to mention is 1 power supply in all of them).

View 6 Replies View Related

Cisco Switching/Routing :: 3750 - VLAN Flapping Error Message

Sep 15, 2012

I recently upgraded my network to have two 3750x core, one interface on the Cisco is connecting to a Net gear switch via a fiber converter. I am keep getting the vlan flapping error message in my log as below.
 
003396: Sep 17 01:46:16.328: %SW_MATM-4-MACFLAP_NOTIF: Host 5c0e.8ba7.0a5c in vlan 2 is flapping between port Gi2/0/15 and port Gi2/0/13
003397: Sep 17 01:46:19.843: %SW_MATM-4-MACFLAP_NOTIF: Host 5c0e.8ba7.0a5c in vlan 2 is flapping between port Gi2/0/15 and port Gi2/0/13
003400: Sep 17 01:49:58.769: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet2/0/17, changed state to down
[Code] .....
 
After my research i think this is a looping issue but I'm unsure how to address it.

View 2 Replies View Related

Cisco Switching/Routing :: 2800 - Does Not Boot And Shows Error Message

Sep 8, 2012

I have a Cisco 2800 series and it doesn't boot, only shows this message in the CLI> 

Bad RAM at location 0xA0000304: wrote 0xA0000304, read 0xA0000004
 
What means this? I have to change the RAM?

View 2 Replies View Related

Cisco Switching/Routing :: 4096 / Syslog Message And Logging Command

Sep 21, 2012

logging buffered 4096 warnings The above causes router to log all the events with severity level 4 or below in buffer.What about logging console warnings  command?will the above command  cause router to send log messages with severity level 4( warnings severity level) to console only or will the router send all the log messages with severity level 4 or below to console ?

View 3 Replies View Related

Cisco Switching/Routing :: Error Message Ports Flapping On 3750 Stack

Aug 27, 2012

I am receiving the following error message on a Cisco 3750 switch stack. Need troubleshooting this error message.

00:03:13: %SW_MATM-4-MACFLAP_NOTIF: Host 00d0.7400.2730 in vlan 600 is flapping between port Gi2/0/3 and port Gi2/0/2

View 3 Replies View Related

Cisco Switching/Routing :: Upgraded 2960 Switches To 15.0 (1) SE - Syslog Message On Bootup

Oct 8, 2011

I recently upgraded a few 2960 switches to 15.0(1)SE, and while they are working fine, I did notice a strange syslog message upon boot-up that wasn't previously there. [code] I did some cursory searching via google but nothing useful presented itself.

View 7 Replies View Related

Cisco Switching/Routing :: Cat 3750E Failed To Send HRPC Non Blocking Message

Mar 23, 2012

I have a stack of Catalyst 3750E switches.

IOS image :c3750e-ipbasek9-mz.122-55.SE3.bin

I have been seeing multiple occurance of the below message in the switch logs.

"Failed to send hrpc non blocking message"

I could not find a relevant reference for this message in the Cisco.com.

View 4 Replies View Related

Cisco Switching/Routing :: 6509 / Mac Address Error Message No Entries Present

Dec 6, 2012

I am receiving this error after connecting a copper adapter on a GBIC blade in a 6509. Here are the results from the show Interface.  I am waiting to confirm the device on the other side settings but as far as I see I get UP and Up for protocol and line respectively.
 
GigabitEthernet2/11 is up, line protocol is up (connected)
Hardware is C6k 1000Mb 802.3, address is 0009.11e4.f3ce (bia 0009.11e4.f3ce)
Description: RCPBSDEV
MTU 1500 bytes, BW 1000000 Kbit, DLY 10 usec,
reliability 255/255, txload 1/255, rxload 1/255
Encapsulation ARPA, loopback not set

[code]....

View 3 Replies View Related

Cisco Switching/Routing :: Nexus 7K Shows Continuous Tacacs Error Message?

Dec 10, 2012

I have Nexus 7K installations in 2 locations. Both of them have multiple VDCs. In default VDC there are continous tacacs error message though tacacs is not configured. The requests are from various public IPs where thsi VDC is not exposed to Internet at all. What would be t he cause of it?
 
%AUTHPRIV-3-SYSTEM_MSG: pam_aaa:Authentication failed for user root from 195.2.219.2
2012 Dec 11 16:25:28 IDC-FBDTB-AMR2-CN7K-01 %AUTHPRIV-3-SYSTEM_MSG: pam_aaa:Authentication failed for user nagios from 67.78.206.226
- sshd[25797]
2012 Dec 11 16:25:34 IDC-FBDTB-AMR2-CN7K-01 %AUTHPRIV-3-SYSTEM_MSG: pam_aaa:Authentication failed for user nagios from 67.78.206.226
- sshd[25799]

[code]....

View 1 Replies View Related

Cisco Switching/Routing :: TCAM Write Failure Message On 3750x Stack

May 29, 2013

I have a stack of 3750x switches running 15.0 (2) SE2 IOS.   When I reload the switch stack, I am seeing the following message in the logs: IPv6 user port trust TCAM write failed.

View 2 Replies View Related

Cisco Switching/Routing :: 3750E-24PD-S Stack Member Fan Failed Syslog Message

Aug 6, 2012

I have a pair of 3750E-24PD-S stacked together, it seems after stacked together the stacked switch always flood the console screen with these messages which are not true: [code] Switch-2 is the stack member, Switch-1 is the stack master. The RPS fan failed refers to RPS2300 or the internal power supply of 3750E? Even when I turned on the RPS2300 the stacked switch still display the messages. Also I have two RPS2300 serving stack master and stack member respectively both RPS2300 were switched off why the messages only refer to Switch-2 and not Switch-1? [code]

View 1 Replies View Related

Cisco Switching/Routing :: 2811 - How To Change Contact Information In Sip Invite Message Header

Nov 8, 2011

My 2811 sip gateway send invite to my ITSP server with incorrect IP address in Contact section. It uses the internal ip address instead of using the public ip. As results, the re-invite sent back from ITSP sip server cannot be recieve. Could some tell how to change the ip address in Contact section of the invite message.

View 6 Replies View Related

Cisco Switching/Routing :: NEXUS 7000 Octopus Internal Error In Device 78 Message?

Nov 12, 2012

NEXUS 7000 Octopus internal error in device 78 message. I got this on NEXUS 7000 logs:
 
 Nov 12 22:05:14 smale-outside : 2012 Nov 12 21:05:14 BRST: %MODULE-2-MOD_DIAG_FAIL: Module 2 (serial: JAF1548AMKB) reported failure on ports 2/1-2/32 (Ethernet) due to Octopus internal error in device 78 (device error 0xc4e0025b)
Nov 12 22:05:17 smale-outside : 2012 Nov 12 21:05:17 BRST: %MODULE-2-MOD_FAIL: Initialization of module 2 (serial: JAF1548AMKB) failed
Nov 12 22:05:18 smale-outside : 2012 Nov 12 21:05:18 BRST: %MODULE-2-MOD_FAIL: Initialization of module 2 (serial: JAF1548AMKB) failed

[code]....
 
I only have found:
 
[URL]
 
which does not match reality : No one was configuring Vlans.

View 5 Replies View Related

Cisco Switching/Routing :: Small Business 300 Series / Another Copy Process Is Active Message

Nov 2, 2010

i have major problem with two new Small Business 300 Series switches.Everytime i try to save the running config i get a GUI error message: "Another copy process is active, please try again later."It's also not possible to re-flash the firmware because the GUI stops responding.I have also tried to do this via console access and this produces a "the copy utility is occupied by another user" error message.-> so this is not a browser based problem.My first thought was that the switch (SG 300-28) is faulty so i unpacked the next new one (SF 300)and got the same error messages!Then i had a 2 hour webex support session with the Cisco Small Business Support and they did not found a reason for this behavior.Both switches are working normally, you can configure them, but after a reboot they are back to factory default again There is no possibilty for copy running config to startup config and it's also not possible to flash the firmware.(Web GUI & Console). tell me if this is a fundamental problem of the 300 Series?

View 6 Replies View Related

Cisco Switching/Routing :: When Connect Router 2821 Through Console / Get Error Message At Regular Interval Of Time

Feb 9, 2013

When  i connect  the Router   2821   through  the  Consol   get  error  message  at  regular  interval  of  time  %ENVMON-4-FAN_LOW_RPM: Fan 1 service recommended.

View 2 Replies View Related

Cisco Switching/Routing :: 3560E Switch 10 Gigbit Uplink For The Switch

Apr 23, 2012

I need 10gigbit uplink for this switch. What are the other devices that i need order along with this device.And what is the diff between  X2-10GB-LR= and CVR-X2-SFP.if i take CVR-X2-SFP, in future how can i upgrade from one gig to 10 gig?for current use i need 10gig support required. so what are all the other devices that i need to order.Fiber multimode and distance 15Mt only.

View 2 Replies View Related







Copyrights 2005-15 www.BigResource.com, All rights reserved