I've installed version 4.8.02.0010 of the VPN client onto a Dell Latitude D820 laptop. When I attempt to connect, I get this message. There are no firewalls running (I disabled the Windows XP firewall) and I'm running under Service Pack 2 with all of the latest security patches from Microsoft.
I even tried un-installing the client and using an older version (4.8.00.0440) and it reports a similar error in the Log file.
I'd prefer to NOT have to wipe the laptop and reinstall the O/S if I don't have to. This is the only laptop that I've experienced this problem with but it's also the first Dell Latitude D820 that I've attempted to install the client on.
Is there a problem with the Dell Latitudes and the VPN Client? Is there another way around this other than a wipe and re-install?
We are using LMS 3.2.1 with SP1 and Campus Manager 5.2.2.Server runs Windows 2003 R2.Everything runs fine except for User Tracking on two Catalyst 6500 switches running CatOS. These devices are discovered, reachable, SNMP works fine, neighbors seen. But when we try to launch acquisition, the UT utility complains with this error message:"Failed to start acquisition: Device unreachable. Please enter a valid device."When we wanted to add ports via Device Trap Configuration, LMS has fired a different error message: "There are no ports to configure for the selected device(s).Check whether you have selected any router(s)." I have checked the portsData.xml file, which doesn't have any ports included for the two devices: [code] We have tried to exclude / include the switches in the data collection, but that didn't work.
after upgrading the firmware on the wireless lan controller 5.2.178.0 on my cisco 4402 wlc's and rebooted the devices, I am getting matches on the audit status between whats on the contoller and the wcs software. so i am trying to apply whats in the wcs templates created for the controller and i am getting this error.
SNMP operation to Device failed: Attempt to set conflicting attribute value
I am thinking that i need to rebooted the wlc's again because from the error it sounds like the values that i am trying to write to the controllers are already present
MGMcc solved my set up problem with my KDL-32ex713 which (i've swapped for a new model - its a long story). I used exactly the same ip addresses for the set up on this KDL-373x524 and got messages "wireless device found, local access failed, internet access failed". As my router and pc are the same as last time why the set up doesn't work this time and what I should do?
I am trying to install Cisco Connect for my E1000 but I get the following error each attempt "An HNAP Call to the device failed for unknown reasons" I've already updated the router to 2.1 version of the Firmware.
Full Details
Error code: 82BD0305Error description: An HNAP call to the device failed for an unknown reason.Model name: unknownModel number: E1000Serial number: unknownFirmware version: unknownOperating system: Windows 7 SP 1Software version: 1.3.11069.2Connection type (WAN): unknownIP address (LAN): unknownIP address (WAN): unknownComputer IP address: 192.168.1.132
i get for all devices telnet credential failed in my credential verification report. I exported the device from the Device Manager into a csv file to verify the correct passwords.The export shows the correct values in
I try to export a Detailed Device Report to a CSV. It failes:
<HTML><META HTTP-EQUIV="content-type" CONTENT="text/html;charset=utf-8"> <H1>HTTP Status 500 - </H1><HR SIZE=1 noShade> <P><B>type</B> Exception report</P><P><B>message</B> <U></U></P><P><B>description</B> <U>The server encountered an internal error () that prevented it from fulfilling this request.</U></P><P><B>exception</B>
[code].....
Exporting to PDF works OK.CW is running on Windows server. RME is 4.3.1
I am trying image distribution to a c3560 device but I always get the error message SWIM1164. In the documentation it says to copy the logs and open a TAC Case but I would like to do some troubleshooting myself before opening a case.
I just reinstalled my Inspiron 1720 and everything works fine but the Bluetooth Peripheral Device which keeps reinstalling after every reboot.
In device manager Bluetooth Radios, "Dell Truemobile 355 Bluetooth + EDR" and "Microsoft Bluetooth Enumerator" are installed properly but I have in "Other devices" a Bluetooth Peripheral Device which does not want to install.
I used Driver CD provided when I purchased my laptop but it does not find any drivers to solve the problem. I also went to dell.com drivers to fin the latest one and this neither does not work .
I have an AIR-AP1131AG-E-K9 running as root AP with three SSID's (mbssid), all WPA-2 PSK, IOS 12.4(25d)JA Now I would like to use an AIR-AP1231G-E-K9 as repeater for one of the SSID's (all three are AFAIK not possible), IOS 12.3.8-JEE(ED) So only one SSID is used.
I use exactly the same shared secrets and security settings on both devices, on the repeater the SSID is designated as infrastructure-ssid.Unfortunately I have the problem that the repeater AP cannot associate with the root AP.I have verified that aironet extensions are enabled, same security settings are used and checked many sites on the net which describe how to configure a repeater AP. Is there any incompatibility between these two APs? I have two of the AIR-AP1231-G-E-K9 APs available, do I need to use the same models?
We are using Catalyst 3750 switch stacks with software 12.2(44)SE. We have two stacks, only one with IP routing enabled.When we try to run an Acquisition Action on this, from Admin> Collection Settings> User Tracking, the system replies with an error "Failed to start acquisition: Device unreachable. Please enter a valid device"device Center reports "success" on all collector status.Acquisition starts successfully when we try with the other stack.With LMS 4.1 demo, users acquisition runs successfully.
I am using ISE 1.1.1.268 and WLC 7.2.111.3 and NAC agent version 4.9.1.6 on Windows 7 Client machines.
About once a day i get the error "ISE Alarm (WARNING): Dynamic Authorization Failed for Device".
The device it is referring to is my NAD, a WLC 5508 running 7.2.111.3
I have looked at the logs and I cannot see anything in the logs which corresponds to this message so that I can troubleshoot further. Maybe I can if I am enabling the correct logging level on the correct ISE component.
What are the components and the logging level that I should set to get some more detail about this error?
At the moment, I have only set debug logging on Active Directory. I have TRACE logging set on Posture, Run time AAA & prrt-JNI.
I do not want to enable too much debug logs, so what is the specific element that I should be debugging.
I thought debugging the posture element would be enough but when I look at the logs there is nothing there that relates to this message.
Version 12.3 I currently have an open authenication customer network, I would like to add a second securt ssid for my sales department, is this possible, how do I do this, the more specific the better .
The installation of an ACE-4710 throughput upgrade license licence (ACE-AP-02-UP1) failed with an error message :CH01AC03/Admin# license install disk0:ACE20111213081741975.lic.Installing license... failed: No space left on device. [code]
I am currently running WCS 7.0.230 I have controllers that are 2500 that are running 7.4.100.60?
My problem is that when I try to add my controller that is a Cisco 5500 running the same 7.4.100.60 I am getting the error SNMP operation to Device failed: Sparse table not supported. Verify that the WCS and WLC versions are compatible and try again.
I have double checked SNMP strings, IP Addressing and everything else I can think of. It just doesn't make sense that I can add a Controller with the same image but different hardware and no the other to the WCS server.
I'm having the following issue with a couple of 1231's.
Some overall config info first:
This is a small office with 2x Catalyst 2950 (24-port, no PoE) switches and 4 AP1231G (autonomous). The APs get PoE from a PWRINJ3 each. The injectors are powered by the AP power supplies. Injectors and power supplies are mounted in the patch closet.
The 2 switches are connected together over 4 ports (20-23 on each switch), these ports are set to 1Q Trunk mode.
The APs are connected to the switches, 2 to each switch, on port 1-2. These ports again are configured as 1Q Trunk.
All this has been working without problems for a number of years.
A few weeks back, AP2 did not restart after a power cut (everything else did). All LEDs are off, port on switch has no LEDs lit. I did not get around to investigating this furtehr until last week. I unmounted (failed) AP2, took it to the spot where (working) AP3 hangs, and plugged it to the cable of AP3. AP2 came to life immediately. I unplugged it and plugged AP3 back in, which restarted immediately.
So I suspect a power supply issue on AP2. I took the injector and power supply that fed AP2 out of the patch closet. When connecting AP2 directly to the power supply, it came to life immediately. So I figure the injector is defective.
On the same day, I notice AP4 is also dead (again all LEDs off, no idea how long, could have been that day or could have been a few days - it has definitely been working after the power cut that appeared to have killed AP2).
So I order 2 new PWRINJ3s and for good measure 2 new power supplies. Later that day, I took the injector and power supply that fed AP4 out of the patch closet. When I try this combination (AP4, injector4 and P/S4), and connect it to a different wall outlet (and therefore a different port -16 - on the switch) IT WORKS! Should have triggered questions, but did not immediately.
Last Thursday I got the new injectors and power supplies. So I take one of each, hook them upto AP2 at my desk, and AP2 starts up. So I mount new injector2 and new P/S2 in the patch closet, put AP2 back in its place, connect all the cables - NOTHING. AP2 does not start. The "power" LED on the injecvtor lights up green, the "device status" LED remains off. I take AP2, new injector2 and new P/S2 to my desk, hook them upto a wall outlet (connected to switch port 17). AP2 starts immediately.
Meanwhile AP3 has (also) stopped working (no LEDs on at all). As far as I can tell, it stopped working after I briefly disconnected (and reconnected) the patch cable between injector3 and the patch panel in the patch closet. The LEDs on switch port 1 are off.
I have since tried to power cycle both switches (took power off both, waited a while, poewerd both back on). No change.
PS: the APs ran firmware 12.3(8)-JA until recently. AP1, AP3 and AP4 were upgraded to 12.3(8)-JEE after the the power cut that took AP2 out. THis is when I found out AP2 was dead. AP2 was still on 12.3(8)-JA. It was upgraded to 12.3(8)-JEE last week when it was on direct power on my desk.
I have an Inspiron 1545 and I reinstalled Vista 32-bit, but I having problems with the comms driver (Conexant D400, External USB 56k Modem Rev : a05) and having the following message appear when I install the driver?
I can't find any information that the AP1231G-A-K9 AP is supported in a 5508 Controller Based environment with Prime NCS.Could one of the experts confirm or deny?
iam currently trying to replace AP1231G-E-K9 with new equipment / Cisco AP next generation maybe?The problem is that the system, that is going to use the AP is using aironet 350 PCMCIA adapter with LEAP. If in fact we are going to use a new Cisco AP, will the new generation work with Aironet 350 Adapter and support LEAP?
We have this access point AIR-AP1231G-A-K9 for mobile users. current version is c1200-k9w7-mx.123-7.JA4. Sometimes users are able to associate but not getting IP address from dhcp. It shows 0.0.0.0 for the particular client.
I have AP AIR-AP1231G-E-K9 with iOS c1200-k9w7-tar.123-7.JA2 and I want to convert it to Lightweight Mode with iOS image c1200-rcvk9w8 tar.124-21a.JA2. First of all, is it possible? Because I tried to convert from tftp server command (archive download-sw /overwrite /reload tftp://ipaddress/image.tar) and I cannot see in the controller. (controller and aps are in the same network)
we have two WLC model 5508 with software version 7.0.116.0 (25 ap supported for each), i tried to add a new access point air-lap1131ag-e-k9 but after five minuts (maximum) the ap reboot, i replaced :
- power injector - AC/DC adapter - patch ethernet - switch port - switch - ip of the access point - reset a default of all access point i tried - reboot of both wlc
I took the ap and connected directly to the switch (with or without power injector), but the access point reset with this reason.
I have two dinasour APs that I need to fix. They are configured in bridge mode to bridge a few VLANs between two sites. Right now the management IP on BVI 3 interface doesn't work. Does it have to be on BVI1 for it to work? When I say "work" I mean I am able to ping it and use SNMP to monitor it.
I have a E2000 for a half a year now.We have been on hollyday for 5 days so my routers has been shutdown.Today it happend 3 times that my complete LAN disconnected for no reasonI didn't have any wired or wireless connection.